Affinity of Clinoptilolite‐based Zeolites towards Removal of Cd from Aqueous Solutions
Open accessAbstract
Cd removal from aqueous solutions using as‐received and pretreated forms of two different clinoptilolite samples (denoted GC and BC) was investigated and dissimilar sorption affinities were revealed. Equilibrium behavior of systems were modeled using six different adsorption isotherms. The maximum sorption capacities, as obtained from the solubility‐normalized Dubinin‐Astakhov model for as‐received samples, were determined as 0.18 meq/g and 0.12 meq/g for GC and BC, whereas 0.72 meq/g and 0.41 meq Cd/g was determined for their pretreated forms, respectively. Examination of the release of exchangeable cations into the solution at equilibrium and the change of pH were discussed in terms of varying prevalence of ion exchange, dissolution of the sorbent and adsorption.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Acid treatment was found to be more effective than other methods for the treatment.
“The acid treatment was found to be more effective than other methods for the treatment (Bektas ¸ and Kara, 2004;Gedik and Imamoglu, 2008).”
From Adsorption of heavy metals on natural zeolites: A review (2023) · cites this paper as Gedik and Imamoglu, 2008
There are two main categories of reagents to wash and recover natural zeolites by removing heavy metals: acids and alkalis.
“there are two main categories of reagents to wash and recover natural zeolites by removing heavy metals i.e., acids (HCl, H 2 SO 4 , HNO 3 , HCOOH, CH 3 COOH), and alkalis (NaCl, KCl, NH 4 Cl, NaOH, NaHCO 3 , Na 2 CO 3 , KOH, K 2 CO 3 Ca (NO 3 ) 2 ).”
From Adsorption of heavy metals on natural zeolites: A review (2023) · cites this paper as Gedik and Imamoglu, 2008
Cited by
Sorted by citations
Natural zeolites as effective adsorbents in water and wastewater treatment
Wang, S., & Peng, Y. (2010) · Chemical Engineering Journal · doi:10.1016/j.cej.2009.10.029 · Cited by 2,441 · see citing works
Adsorption of heavy metals on natural zeolites: A review
Velarde, L., Nabavi, M. S., Escalera, E., Antti, M.-L., & Akhtar, F. (2023) · Chemosphere · doi:10.1016/j.chemosphere.2023.138508 · Cited by 491 · see citing works
“2) (Anari-Anaraki and Nezamzadeh-Ejhieh, 2015; Asgari et al., 2013; Gedik and Imamoglu, 2008; Ren et al., 2016).”
Influential
- Authors
- Gedik, K., & Imamoglu, I.
- Venue
- Separation Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2008-03
- Volume
- 43
- Issue
- 5
- Pages
- 1191-1207
- ISSN
- 0149-6395 (ISSN-L)
- 1520-5754
- OpenAlex
- W2032942567
- Cited by
- 25
- References
- 0
- Citations by year
- 2024: 1 · 2023: 4 · 2022: 1 · 2021: 2 · 2020: 3 · 2019: 3 · 2017: 1 · 2016: 2 · 2014: 3 · 2013: 1 · 2012: 1
- FWCI
- 1.10
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by-nc-nd
- Locations
- Separation Science and Technology (publishedVersion)
- OpenMETU (Middle East Technical University) (submittedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Environmental Science › Water Science and Technology › Adsorption and biosorption for pollutant removal
- Physical Sciences › Environmental Science › Waste Management and Disposal › Chemical Synthesis and Characterization
- Physical Sciences › Chemistry › Inorganic Chemistry › Zeolite Catalysis and Synthesis
- Keywords
- cadmium removal, clinoptilolite, zeolite adsorption, heavy metal adsorption, adsorption isotherms, Dubinin-Astakhov model, sorption capacity, ion exchange, pH effect, aqueous solutions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review