Cited by 1Analytical chemistry methods developmentAdsorption and biosorption for pollutant removalElectrochemical Analysis and Applications

Trace Isolation and Photometric Determination of Cadmium Ions in Water Using Thermally Reduced Graphene‐Modified Hybrid Sol–Gel Composite

Golmohammadi, Golnaz, Joolaei Ahranjani, Parham, Sereshti, Hassan, Dehghan, Kamine, Sadatfaraji, Hamed, Karami, Sajad, Rashidi Nodeh, Hamid·2025·Separation Science and Technology

Abstract

This study presents the development and application of a thermally reduced graphene (TRG)-modified SiO₂-APTES composite for the extraction and preconcentration of cadmium (Cd (II)) ions from aqueous samples, with quantification by UV-Vis spectrophotometry. To enhance the selectivity of Cd(II) detection, diphenylthiocarbazone (dithizone) was used as a chelating agent prior to the extraction process. Critical parameters, including the type and volume of the desorption solvent, pH, adsorbent dosage, and salt concentration, were systematically investigated and optimized. The optimized method achieved a preconcentration factor of 200 for a 30 mL sample volume. The method demonstrated excellent analytical performance, with a linear dynamic range of 1.0–100 ng·mL−1, a determination coefficient (R2) of 0.995, a limit of detection (LOD) of 0.5 ng·mL−1, and a relative standard deviation (RSD) of 4.1% at a Cd (II) concentration of 10 ng·mL−1 (n = 3). Application to real water samples yielded relative recoveries (RR) of approximately 94%, confirming the method’s reliability and robustness. This approach combines high sensitivity, cost-effectiveness, and operational simplicity, making it a promising tool for trace-level cadmium detection in environmental and water quality monitoring applications.

Integrity signals

Registry

Crossref · 10.1080/01496395.2025.2502753

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Golmohammadi, G., Joolaei Ahranjani, P., Sereshti, H., Dehghan, K., Sadatfaraji, H., Karami, S., & Rashidi Nodeh, H.
Affiliations
  • University of Tehran (IR)
  • Free University of Bolzano
  • University of Milano-Bicocca (IT)
  • University of Maryland, Baltimore County (US)
  • Utah State University (US)
  • University of Tehran
Corresponding author
  • Sereshti, Hassan
  • Karami, Sajad
Venue
Separation Science and Technology
Published
2025-05-15
Volume
60
Issue
11
Pages
1421-1435
ISSN
  • 0149-6395 (ISSN-L)
  • 1520-5754
OpenAlex
W4410400838
Cited by
1
References
1
Citations by year
2025: 1
FWCI
0.38
Type
journal article
Language
en
Open access
closed
Locations
Separation Science and Technology (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Environmental Science › Water Science and Technology › Adsorption and biosorption for pollutant removal
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
Keywords
cadmium determination, sol-gel composites, preconcentration, dithizone, adsorbents, water analysis, heavy metal detection, UV-Vis spectroscopy, water quality monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review