The DOI matches its Crossref record.
Liquid-Liquid Extraction of Low Molecular-Weight Proteins by Selective Solubilization in Reversed Micelles
Abstract
The effects of pH and salt concentration on the solubilization of ribonuclease-a, cytochrome-c and lysozyme in Aerosol OT/isooctane reversed micelle solutions have been studied to explore the potential for employing this solvent system in the large-scale recovery and concentration of proteins using liquid extraction. For pH values below the isoelectric point, pI, of the protein, solubilization was high, probably owing to strong electrostatic-interactions between the positively charged proteins and the anionic surfactant heads forming the inner micelle wall. Above the pI, the proteins could not be solubilized, probably because of unfavorable electrostatic repulsions between the like-charged proteins and surfactants. At low ionic strength and neutral pH, complete solubilization of the proteins was observed. As the ionic strength was increased, there was an abrupt decrease in solubilizing power of the reversed micelle solutions; the salt concentration at which this occurred was different for each protein. A mixture of the three proteins was cleanly resolved using a single extraction step and two stripping steps. The conditions in each step were selected according to the results of the single protein extraction studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reverse micelles as hosts for proteins and small molecules
Luisi, P. L., Giomini, M., Pileni, M. P., & Robinson, B. H. (1988) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(88)90025-1 · Cited by 765
Structure, dynamics and transport properties of microemulsions
Moulik, S. P., & Paul, B. K. (1998) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(98)00063-3 · Cited by 623
Microemulsions: A Potential Delivery System for Bioactives in Food
Flanagan, J., & Singh, H. (2006) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408690590956710 · Cited by 394
Liquid–liquid extraction of biomolecules: an overview and update of the main techniques
Mazzola, P. G., Lopes, A. M., Hasmann, F. A., Jozala, A. F., Penna, T. C., Magalhaes, P. O., Rangel‐Yagui, C. O., & Pessoa Jr, A. (2008) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.1794 · Cited by 300
The use of reverse micelles for the simultaneous extraction of oil and proteins from vegetable meal
Leser, M. E., Luisi, P. L., & Paimieri, S. (1989) · Biotechnology and Bioengineering · doi:10.1002/bit.260340904 · Cited by 50
Metadata
- Authors
- Goklen, K. E., & Hatton, T. A.
- Venue
- Separation Science and Technology
- Publisher
- Informa UK Limited
- Published
- 1987-02
- Volume
- 22
- Issue
- 2-3
- Pages
- 831-841
- ISSN
- 0149-6395 (ISSN-L)
- 1520-5754
- OpenAlex
- W2017477766
- Cited by
- 234
- References
- 0
- FWCI
- 16.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liquid-Liquid Extraction of Low Molecular-Weight Proteins by Selective Solubilization in Reversed Micelles. https://app.cochat.ai/papers/10.1080/01496398708068984
- The paper
- Goklen, K. E., & Hatton, T. A. (1987). Liquid-Liquid Extraction of Low Molecular-Weight Proteins by Selective Solubilization in Reversed Micelles. Separation Science and Technology. https://doi.org/10.1080/01496398708068984
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.