The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
A Statistical Model for Positron Emission Tomography
Abstract
Positron emission tomography (PET)—still in its research stages—is a technique that promises to open new medical frontiers by enabling physicians to study the metabolic activity of the body in a pictorial manner. Much as in X-ray transmission tomography and other modes of computerized tomography, the quality of the reconstructed image in PET is very sensitive to the mathematical algorithm to be used for reconstruction. In this article, we tailor a mathematical model to the physics of positron emissions, and we use the model to describe the basic image reconstruction problem of PET as a standard problem in statistical estimation from incomplete data. We describe various estimation procedures, such as the maximum likelihood (ML) method (using the EM algorithm), the method of moments, and the least squares method. A computer simulation of a PET experiment is then used to demonstrate the ML and the least squares reconstructions. The main purposes of this article are to report on what we believe is an important contribution of statistics to PET and to familiarize statisticians with this exciting field that can benefit from further statistical methodologies to be developed with PET problems in mind. Thus no background in physics or previous knowledge of computerized tomography is assumed. The emphasis is on the basic PET model and the statistical methodology needed for it.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Estimates of I maximizing Eq. 1 can be obtained with an expectation maximization algorithm (6, 33–35), but the outcome is typically unstable (36).”
From Socioeconomic status determines COVID-19 incidence and related mortality in Santiago, Chile (2021) · cites this paper as [34]
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Linear Statistical Inference and its Applications
Rao, C. R. (1973) · Wiley series in probability and statistics · doi:10.1002/9780470316436 · Cited by 10,474
Iterative Solution of Nonlinear Equations in Several Variables
Ortega, J. M., & Rheinboldt, W. C. (2000) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898719468 · Cited by 6,919
Journal of The American Statistical Association
Fienberg, S. E. (2004) · Encyclopedia of Statistical Sciences · doi:10.1002/0471667196.ess1317 · Cited by 6,289
Maximum likelihood estimation from incomplete data via the EM algorithm
Dempster, A. P. (1977) · Journal of the Royal Statistical Society Series A (Statistics in Society) · Cited by 4,543
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Self-citationThe Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,202
Self-citationEM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,775
Nonlinear Programming: A Unified Approach.
Beale, E. M. L., & Zangwill, W. I. (1970) · Journal of the Royal Statistical Society Series A (General) · doi:10.2307/2343701 · Cited by 1,059
Nonlinear Programming: A Unified Approach
Peterson, D. W., & Zangwill, W. I. (1972) · Econometrica · doi:10.2307/1909424 · Cited by 1,011
Research works printed but not linked: 2
- Lakshminarayanan , A. V. 1975 . “Reconstruction From Divergent Ray Data,” , State University of New York at Buffalo, Computer Science Dept. . Technical Report No. 92
- Peng , J. C. M. 1975 . “Simultaneous Estimation of the Parameters of Independent Poisson Distributions,” , Stanford University, Dept. of Statistics . Technical Report No. 78
Cited by
Sorted by citations
Items 101–200 of 861
Extended depth of field imaging for high speed cell analysis
Ortyn, W. E., Perry, D. J., Vidya Venkatachalam, A., Liang, L., Hall, B. E., Frost, K., & Basiji, D. A. (2007) · Cytometry Part A · doi:10.1002/cyto.a.20370 · Cited by 85
Cho, Z., Son, Y., Kim, H., Kim, K., Oh, S., Han, J., Hong, I., & Kim, Y.-B. (2008) · PROTEOMICS · doi:10.1002/pmic.200700744 · Cited by 82
Tanaka, E. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307809 · Cited by 81
Primal and Dual Bregman Methods with Application to Optical Nanoscopy
Brüne, C., Sawatzky, A., & Burger, M. (2010) · International Journal of Computer Vision · doi:10.1007/s11263-010-0339-5 · Cited by 79
Byrne, C. L., & Censor, Y. (2001) · Annals of Operations Research · doi:10.1023/a:1013349430987 · Cited by 79
Iterative algorithms for deblurring and deconvolution with constraints
Byrne, C. L. (1998) · Inverse Problems · doi:10.1088/0266-5611/14/6/006 · Cited by 72
Holmes, T. J., & Liu, Y.-H. (1991) · Journal of the Optical Society of America A · doi:10.1364/josaa.8.000893 · Cited by 72
Weighted least-squares reconstruction methods for positron emission tomography
Anderson, J. M. M., Mair, B. A., Rao, M., & Wu, C.-H. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563661 · Cited by 72
A multigrid expectation maximization reconstruction algorithm for positron emission tomography
Ranganath, M. V., Dhawan, A. P., & Mullani, N. A. (1988) · IEEE Transactions on Medical Imaging · doi:10.1109/42.14509 · Cited by 72
Preconditioned alternating projection algorithms for maximum a posteriori ECT reconstruction
Król, A., Li, S., Shen, L., & Xu, Y. (2012) · Inverse Problems · doi:10.1088/0266-5611/28/11/115005 · Cited by 71
Poisson image denoising based on fractional-order total variation
Chowdhury, M. R., Zhang, J., Qin, J., & Lou, Y. (2019) · Inverse Problems and Imaging · doi:10.3934/ipi.2019064 · Cited by 70
A statistical measure of tissue heterogeneity with application to 3D PET sarcoma data
O’Sullivan, F. (2003) · Biostatistics · doi:10.1093/biostatistics/4.3.433 · Cited by 69
Shevelev, A., Khilkevitch, E., Kiptily, V., Chugunov, I. N., Gin, D. B., Doinikov, D. N., Naidenov, V. O., Litvinov, A. E., Polunovsky, I. A., & Contributors, J.-E. (2013) · Nuclear Fusion · doi:10.1088/0029-5515/53/12/123004 · Cited by 68
8. Bilevel approaches for learning of variational imaging models
Calatroni, L., Cao, C., Reyes, J. C. D. L., Schönlieb, C., & Valkonen, T. (2016) · De Gruyter eBooks · doi:10.1515/9783110430394-008 · Cited by 75
Weber, S., Terstegge, A., Herzog, H. R., Reinartz, R., Reinhart, P., Rongen, F., Muller-Garmer, H. W., & Halling, H. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.640759 · Cited by 68
Higdon, D., Lee, H., & Bi, Z. (2002) · IEEE Transactions on Signal Processing · doi:10.1109/78.978393 · Cited by 67
Socioeconomic status determines COVID-19 incidence and related mortality in Santiago, Chile
Mena, G., Martinez, P. P., Mahmud, A. S., Marquet, P. A., Buckee, C. O., & Santillana, M. (2021) · doi:10.1101/2021.01.12.21249682 · Cited by 64
Joint additive Kullback–Leibler residual minimization and regularization for linear inverse problems
Resmerita, E., & Anderssen, R. (2007) · Mathematical Methods in the Applied Sciences · doi:10.1002/mma.855 · Cited by 64
First Order Algorithms in Variational Image Processing
Burger, M., Sawatzky, A., & Steidl, G. (2016) · Scientific computation · doi:10.1007/978-3-319-41589-5_10 · Cited by 67
Higher SNR PET image prediction using a deep learning model and MRI image
Liu, C., & Qi, J. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab0dc0 · Cited by 68
Teymurazyan, A., Riauka, T., Jans, H., & Robinson, D. M. (2012) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-012-9511-5 · Cited by 65
Total Variation Processing of Images with Poisson Statistics
Sawatzky, A., Brüne, C., Müller, J., & Burger, M. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-03767-2_65 · Cited by 64
Maxim, V., Lojacono, X., Hilaire, E., Krimmer, J., Testa, É., Dauvergne, D., Magnin, I. E., & Prost, R. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/1/243 · Cited by 64
On iterative algorithms for linear least squares problems with bound constraints
Bierlaire, M., Toint, P. L., & Tuyttens, D. (1991) · Linear Algebra and its Applications · doi:10.1016/0024-3795(91)90009-l · Cited by 64
On the Iterative Image Space Reconstruction Algorthm for ECT
Titterington, D. M. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307797 · Cited by 64
Scheins, J. J., Herzog, H. R., & Shah, N. J. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2109732 · Cited by 63
Hohage, T., & Werner, F. (2012) · Numerische Mathematik · doi:10.1007/s00211-012-0499-z · Cited by 62
Brix, G., Doll, J., Bellemann, M. E., Trojan, H., Haberkorn, U., Schmidlin, P., & Ostertag, H. J. (1997) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf00879667 · Cited by 62
Enhanced 3D PET OSEM reconstruction using inter-update Metz filtering*
Jacobson, M. W., Levkovitz, R., Ben‐Tal, A., Thielemans, K., Spinks, T. J., Belluzzo, D., Pagani, E., Bettinardi, V., Gilardi, M. C., Zverovich, A., et al. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/8/325 · Cited by 61
An evaluation of maximum likelihood reconstruction for SPECT
Chornoboy, E. S., Chen, C. J., Miller, M. I., Miller, T. R., & Snyder, D. L. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.52987 · Cited by 61
Statistical Modelling by Exponential Families
Sundberg, R. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108604574 · Cited by 58
System models for PET statistical iterative reconstruction: A review
Iriarte, A., Marabini, R., Matej, S., Sorzano, C. Ó. S., & Lewitt, R. M. (2015) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2015.12.003 · Cited by 59
Maximum Likelihood Estimation of a Neutron Spectrum and Associated Uncertainties
Cvachovec, J., & Cvachovec, F. (2008) · Advances in Military Technology · Cited by 60
Iterative Optimization in Inverse Problems
Byrne, C. L. (2014) · Chapman & Hall/CRC eBooks · doi:10.1201/b16485 · Cited by 59
Maximum smoothed likelihood for multivariate mixtures
Levine, M., Hunter, D. R., & Chauveau, D. (2011) · Biometrika · doi:10.1093/biomet/asq079 · Cited by 59
EM-TV Methods for Inverse Problems with Poisson Noise
Sawatzky, A., Brüne, C., Kösters, T., Wübbeling, F., & Burger, M. (2013) · Lecture notes in mathematics · doi:10.1007/978-3-319-01712-9_2 · Cited by 58
A review on biomedical image processing and future trends
Dhawan, A. P. (1990) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(90)90001-p · Cited by 57
Statistical stopping criteria for iterative maximum likelihood reconstruction of emission images
Herbert, T. J. (1990) · Physics in Medicine and Biology · doi:10.1088/0031-9155/35/9/003 · Cited by 57
Volume emission rate tomography from a satellite platform
Degenstein, D. A., Llewellyn, E. J., & Lloyd, N. D. (2003) · Applied Optics · doi:10.1364/ao.42.001441 · Cited by 56
Kempen, V., & A, L. J. V. V. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00671.x · Cited by 55
Martínez-Murcia, F. J., Górriz, J. M., Ramı́rez, J., Illán, I. A., & Ortíz, A. (2013) · Neurocomputing · doi:10.1016/j.neucom.2013.01.054 · Cited by 54
Parallelizable Bayesian tomography algorithms with rapid, guaranteed convergence
Zheng, J., Saquib, S. S., Sauer, K. D., & Bouman, C. A. (2000) · IEEE Transactions on Image Processing · doi:10.1109/83.869186 · Cited by 54
Fully Bayesian Reconstructions From Single-Photon Emission Computed Tomography Data
Weir, I. S. (1997) · Journal of the American Statistical Association · doi:10.1080/01621459.1997.10473602 · Cited by 54
Bao, Q., & Chatziioannou, A. F. (2010) · Medical Physics · doi:10.1118/1.3495817 · Cited by 53
Improved nano-particle tracking analysis
Walker, J. (2012) · Measurement Science and Technology · doi:10.1088/0957-0233/23/6/065605 · Cited by 53
Alternative EM methods for nonparametric finite mixture models
Pilla, R. S. (2001) · Biometrika · doi:10.1093/biomet/88.2.535 · Cited by 53
Coakley, K. J. (1991) · IEEE Transactions on Nuclear Science · doi:10.1109/23.64635 · Cited by 53
The EM Algorithm: A Guided Tour
Couvreur, C. (1997) · Birkhäuser Boston eBooks · doi:10.1007/978-1-4612-1996-5_12 · Cited by 52
Likelihood maximization for list-mode emission tomographic image reconstruction
Byrne, C. L. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.959305 · Cited by 52
Bayesian Methods for Censored Categorical Data
Dickey, J., Jiang, J.-M., & Kadane, J. B. (1987) · Journal of the American Statistical Association · doi:10.1080/01621459.1987.10478498 · Cited by 52
Discretization effects in statistical inverse problems
Johnstone, I. M., & Silverman, B. W. (1991) · Journal of Complexity · doi:10.1016/0885-064x(91)90042-v · Cited by 52
Bregman-EM-TV Methods with Application to Optical Nanoscopy
Brüne, C., Sawatzky, A., & Burger, M. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02256-2_20 · Cited by 51
A new iterative algorithm to reconstruct the refractive index
Liu, Y., Zhu, P., Chen, B., Wang, J. Y., Yuan, Q., Huang, W., Shu, H., Li, E. R., Liu, X. S., Zhang, K., et al. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/l01 · Cited by 51
An Intensity Similarity Measure in Low-Light Conditions
Alter, F., Matsushita, Y., & Tang, X. (2006) · Lecture notes in computer science · doi:10.1007/11744085_21 · Cited by 51
Bousse, A., Bertolli, O., Atkinson, D., Arridge, S., Sebastien Ourselin, A., Hutton, B. F., & Thielemans, K. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2464156 · Cited by 50
Carbon ions beam therapy monitoring with the INSIDE in-beam PET
Pennazio, F., Battistoni, G., Bisogni, M. G., Camarlinghi, N., FERRARI, A., Ferrero, V., Fiorina, E., Morrocchi, M., SALA, P. R., Sportelli, G., et al. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aacab8 · Cited by 50
Conchello, J.-A., Kim, J. J., & Hansen, E. W. (1994) · Applied Optics · doi:10.1364/ao.33.003740 · Cited by 50
A Model for Segmentation and Analysis of Noisy Images
Johnson, V. E. (1994) · Journal of the American Statistical Association · doi:10.1080/01621459.1994.10476464 · Cited by 50
Interior-point methodology for 3-D PET reconstruction
Johnson, C. A., Seidel, J., & Sofer, A. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.848179 · Cited by 49
Double-bunch unfolding methods for the Back-n white neutron source at CSNS
Han, Y., Wang, T. F., Li, Y., Ruan, X., Ren, J., Chen, Y., Li, Q., Wen, J., Tang, J., An, Q., et al. (2020) · Journal of Instrumentation · doi:10.1088/1748-0221/15/03/p03026 · Cited by 48
Alternating Minimization as Sequential Unconstrained Minimization: A Survey
Byrne, C. L. (2012) · Journal of Optimization Theory and Applications · doi:10.1007/s10957-012-0134-2 · Cited by 46
An Analysis of the EM Algorithm and Entropy-Like Proximal Point Methods
Tseng, P. (2004) · Mathematics of Operations Research · doi:10.1287/moor.1030.0073 · Cited by 46
Comparing maximum likelihood estimation and constrained Tikhonov-Miller restoration
van Kempen, G. M. P., van der Voort, H. T. M., Bauman, J. G. J., & Strasters, K. C. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.482846 · Cited by 46
Superiorization of the ML-EM Algorithm
Garduño, E., & Herman, G. T. (2013) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2013.2283529 · Cited by 45
A Novel Sparsity Reconstruction Method from Poisson Data for 3D Bioluminescence Tomography
Zhang, X., Lu, Y., & Chan, T. F.-C. (2011) · Journal of Scientific Computing · doi:10.1007/s10915-011-9533-z · Cited by 45
Roth, C., Degenstein, D. A., Bourassa, A., & Llewellyn, E. J. (2007) · Canadian Journal of Physics · doi:10.1139/p07-130 · Cited by 45
The expectation-maximization algorithm for ill-posed integral equations: a convergence analysis
Resmerita, E., Engl, H. W., & Iusem, A. N. (2007) · Inverse Problems · doi:10.1088/0266-5611/23/6/019 · Cited by 45
Alternating Minimization Algorithms: From Blahut-Arimoto to Expectation-Maximization
O’Sullivan, J. A. (1998) · Springer eBooks · doi:10.1007/978-1-4615-5121-8_13 · Cited by 45
A Variational Framework for Region-Based Segmentation Incorporating Physical Noise Models
Sawatzky, A., Tenbrinck, D., Jiang, X., & Burger, M. (2013) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-013-0419-6 · Cited by 44
Joint solution for PET image segmentation, denoising, and partial volume correction
Xu, Z., Gao, M., Papadakis, G. Z., Luna, B. M., Jain, S. K., Mollura, D. J., & Bağcı, U. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.03.007 · Cited by 45
Butucea, C., Guţǎ, M., & Artiles, L. M. (2007) · The Annals of Statistics · doi:10.1214/009053606000001488 · Cited by 44
Schmitt, D., Karuta, B., Carrier, C., & Lecomte, R. (1988) · IEEE Transactions on Medical Imaging · doi:10.1109/42.3923 · Cited by 44
Direct Parametric Image Reconstruction in Reduced Parameter Space for Rapid Multi-Tracer PET Imaging
Cheng, X., Li, Z., Liu, Z., Navab, N., Huang, S., Keller, U. B., Ziegler, S. I., & Shi, K. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2403300 · Cited by 43
Modern Statistical Challenges in High-Resolution Fluorescence Microscopy
Aspelmeier, T., Egner, A., & Munk, A. (2015) · Annual Review of Statistics and Its Application · doi:10.1146/annurev-statistics-010814-020343 · Cited by 44
A globally convergent primal-dual active-set framework for large-scale convex quadratic optimization
Curtis, F. E., Han, Z. S., & Robinson, D. P. (2014) · Computational Optimization and Applications · doi:10.1007/s10589-014-9681-9 · Cited by 43
A Multiplicative Iterative Algorithm for Box-Constrained Penalized Likelihood Image Restoration
Chan, R. H.-F., & Ma, J. (2012) · IEEE Transactions on Image Processing · doi:10.1109/tip.2012.2188811 · Cited by 43
Maximum Smoothed Likelihood Density Estimation for Inverse Problems
Eggermont, P. P. B., & LaRiccia, V. N. (1995) · The Annals of Statistics · doi:10.1214/aos/1176324463 · Cited by 43
Inhomogeneous Prior Models for Image Reconstruction
Aykroyd, R. G., & Zimeras, S. (1999) · Journal of the American Statistical Association · doi:10.1080/01621459.1999.10474198 · Cited by 42
Poisson intensity estimation for tomographic data using a wavelet shrinkage approach
Cavalier, L., & Koo, J.-Y. (2002) · IEEE Transactions on Information Theory · doi:10.1109/tit.2002.802632 · Cited by 42
Vector-extrapolated fast maximum likelihood estimation algorithms for emission tomography
Rajeevan, N., Rajgopal, K., & Krishna, G. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.126905 · Cited by 42
Quantitation of dynamic total-body PET imaging: recent developments and future perspectives
Gu, F., & Wu, Q. (2023) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-023-06299-w · Cited by 41
Statistical analysis of MR imaging and its applications in image modeling
Wang, Y., & Lei, T. (2002) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.1994.413438 · Cited by 41
On properties of the iterative maximum likelihood reconstruction method
Mülthei, H. N., Schorr, B., & Törnig, W. (1989) · Mathematical Methods in the Applied Sciences · doi:10.1002/mma.1670110303 · Cited by 41
An EM algorithm for dynamic SPECT
Bauschke, H. H., Noll, D., Celler, A. M., & Borwein, J. M. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.764899 · Cited by 41
Effective Emission Tomography Image Reconstruction Algorithms for SPECT Data
Ramı́rez, J., Górriz, J. M., Gómez-Río, M. M., Romero, A. E., Chaves, R., Lassl, A., Rodríguez, A., Puntonet, C. G., Theis, F. J., & Lang, E. W. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-69384-0_79 · Cited by 40
On methods for maximum a posteriori image reconstruction with a normal prior
Herman, G. T., Pierro, Á. R. D., & Gai, N. (1992) · Journal of Visual Communication and Image Representation · doi:10.1016/1047-3203(92)90035-r · Cited by 40
Background estimation in nonlinear image restoration
van Kempen, G. M. P., & A, L. J. V. V. (2000) · Journal of the Optical Society of America A · doi:10.1364/josaa.17.000425 · Cited by 40
Some properties of adding a smoothing step to the EM algorithm
Nychka, D. W. (1990) · Statistics & Probability Letters · doi:10.1016/0167-7152(92)90015-w · Cited by 40
Graphics Processing Units and High-Dimensional Optimization
Zhou, H., Lange, K., & Suchard, M. A. (2010) · Statistical Science · doi:10.1214/10-sts336 · Cited by 39
Restoration of Astrophysical Images—The Case of Poisson Data with Additive Gaussian Noise
Lantéri, H., & Theys, C. (2005) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/asp.2005.2500 · Cited by 39
Bayesian image reconstruction in positron emission tomography
Chen, C.-T., Johnson, V. E., Wong, W. H., Hu, X. P., & Metz, C. E. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106690 · Cited by 39
Metabolic images from dynamic positron emission tomography studies
O’Sullivan, F. (1994) · Statistical Methods in Medical Research · doi:10.1177/096228029400300106 · Cited by 39
A First Course in Optimization
Byrne, C. L. (2014) · Chapman & Hall/CRC eBooks · doi:10.1201/b17264 · Cited by 38
A Linear Spatial Correlation Model, With Applications to Positron Emission Tomography
Worsley, K. J., Evans, A. C., Strother, S. C., & Tyler, J. L. (1991) · Journal of the American Statistical Association · doi:10.1080/01621459.1991.10475004 · Cited by 38
Image Restoration in Fluorescence Microscopy
van Kempen, G. M. P. (1999) · Research Repository (Delft University of Technology) · Cited by 38
Non-smooth Non-convex Bregman Minimization: Unification and New Algorithms
Ochs, P., Fadili, J. M., & Brox, T. (2018) · Journal of Optimization Theory and Applications · doi:10.1007/s10957-018-01452-0 · Cited by 37
Image recovery from correlations
Schulz, T. J., & Snyder, D. L. (1992) · Journal of the Optical Society of America A · doi:10.1364/josaa.9.001266 · Cited by 37
High performance gamma-ray spectrometer for runaway electron studies on the FT-2 tokamak
Shevelev, A., Khilkevitch, E., Lashkul, S. I., Rozhdestvensky, V. V., Altukhov, A. B., Chugunov, I. N., Doinikov, D. N., Esipov, L. A., Gin, D. B., Iliasova, M., et al. (2016) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2016.05.075 · Cited by 35
On the Linear Convergence of Forward–Backward Splitting Method: Part I—Convergence Analysis
Bello-Cruz, Y., Li, G., & Nghia, T. T. A. (2020) · Journal of Optimization Theory and Applications · doi:10.1007/s10957-020-01787-7 · Cited by 34
Chinn, G., & Huang, S. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.552050 · Cited by 35
Metadata
- Authors
- Vardi, Y., Shepp, L. A., & Kaufman, L.
- Affiliations
- AT&T (United States) (US)
- Venue
- Journal of the American Statistical Association
- Publisher
- Informa UK Limited
- Published
- 1985-03
- Volume
- 80
- Issue
- 389
- Pages
- 8-20
- ISSN
- 0162-1459 (ISSN-L)
- 1537-274X
- OpenAlex
- W1967374611
- Cited by
- 863
- References
- 27
- Citations by year
- 2026: 10 · 2025: 12 · 2024: 10 · 2023: 14 · 2022: 14 · 2021: 29 · 2020: 25 · 2019: 44 · 2018: 19 · 2017: 22 · 2016: 32 · 2015: 31 · 2014: 31 · 2013: 25 · 2012: 27
- FWCI
- 13.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American Statistical Association (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
- Keywords
- positron emission tomography, image reconstruction, statistical models, missing data, maximum likelihood estimation, expectation-maximization algorithm, method of moments, least squares, statistical estimation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review