The DOI matches its Crossref record.
UV/H2O2Treatment: A Practical Solution for Organic Contaminant Control and Primary Disinfection
Abstract
PWN's water treatment plant Andijk was commissioned almost 40 years ago. It services water from the IJssel Lake by conventional surface water treatment. In view of taste and odor problems the plant was retrofitted with GAC filtration 25 years ago. The finished water quality still complies with all E.C. and Dutch drinking water standards. Nevertheless an upgrade is desired to avoid the use of chlorine and to extend the barriers against pathogenic micro-organisms and a broad range of organic micropollutants such as pesticides, rocket fuel by-products (NDMA), fuel oxygenates (MTBE), solvents (dioxane), endocrine disruptors, algae toxins, pharmaceuticals, etc. UV/H2O2 treatment was selected for both primary disinfection and organic contaminant control. The disinfection requirements were based on a 10−4 health risk. The required 3 log inactivation for Giardia and Cryptosporidium was achieved by an UV dose lower than 20 mJ/cm2. The highest UV dose, 105 mJ/cm2, was needed for the inactivation of spores of Sulphite Reducing Clostridia. Reactivation of protozoa was established for UV doses up to 25 mJ/cm2, for doses higher than 45 mJ/cm2 no reactivation was observed. In view of the raw water concentrations the required organic contaminant degradation was set at 80%. Collimated beam and pilot-plant work showed that the required degradation can be achieved by the proper combination of electric energy and H2O2. In a UV reactor optimized for organic contaminant control, UV dose of 540 mJ/cm2 (about 0.5 kWh/m3) and 6 mg/L H2O2 were needed. Under those conditions pesticides (atrazine), NDMA, MTBE, dioxane, endocrine disruptors (bisphenol A), microcystine and pharmaceuticals (diclofenac, ibuprofen) could be removed up to the required 80%. Bromate formation was absent while formation of primary metabolites was insignificant. The UV dose for organic contaminant control is about five times higher than the dose needed for disinfection. The UV/H2O2 process was implemented into the existing treatment train between the sand and GAC filters. In the GAC filters excess H2O2 is degraded, nitrite is converted into nitrate and biodegradable reaction products are consumed by bacteria. The full-scale installation with 3 streets of 4 Trojan Swift 16L30 reactors has been in operation since October 2004. Disinfection and organic contaminant control are as expected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Evaluation of advanced oxidation processes for water and wastewater treatment – A critical review
Miklos, D. B., Remy, C., Jekel, M., Linden, K. G., Drewes, J. E., & Hübner, U. (2018) · Water Research · doi:10.1016/j.watres.2018.03.042 · Cited by 3,050
Removal of natural organic matter from drinking water by advanced oxidation processes
Matilainen, A., & Sillanpää, M. (2010) · Chemosphere · doi:10.1016/j.chemosphere.2010.04.067 · Cited by 706
Oxidation Processes in Water Treatment: Are We on Track?
von Gunten, U. (2018) · Environmental Science & Technology · doi:10.1021/acs.est.8b00586 · Cited by 684
Ao, X., & Liu, W. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.12.089 · Cited by 438
Teodosiu, C., Gilca, A.-F., Barjoveanu, G., & Fiore, S. (2018) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2018.06.247 · Cited by 433
Metadata
- Authors
- Kruithof, J. C., Kamp, P. C., & Martijn, B. J.
- Venue
- Ozone: Science & Engineering
- Publisher
- Informa UK Limited
- Published
- 2007-07-31
- Volume
- 29
- Issue
- 4
- Pages
- 273-280
- ISSN
- 0191-9512 (ISSN-L)
- 1547-6545
- OpenAlex
- W2177396565
- Cited by
- 203
- References
- 0
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: UV/H2O2Treatment: A Practical Solution for Organic Contaminant Control and Primary Disinfection. https://app.cochat.ai/papers/10.1080/01919510701459311
- The paper
- Kruithof, J. C., Kamp, P. C., & Martijn, B. J. (2007). UV/H2O2Treatment: A Practical Solution for Organic Contaminant Control and Primary Disinfection. Ozone: Science & Engineering. https://doi.org/10.1080/01919510701459311
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.