CoChat

Chiller: Performance Deterioration and Maintenance

The DOI matches its Crossref record; 26 of the 27 references it cites were found in a registry or an index.

Abstract

Most energy efficiency programs focus on retrofitting or upgrading the equipment. As a matter of fact, maintenance is also a source of energy efficiency improvement. In this article, the performance deterioration of a centrifugal chiller in a hotel is investigated. The result shows that chiller performance deteriorates over time. To restore chiller performance, maintenance actions should be taken.

Overview

Integrity signals

Registry

Crossref · 10.1080/01998595.2016.11728657

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Research works printed but not linked: 21

  1. Evans R., 1998, “The Long Term Costs of Owning and Using Buildings.”
  2. Wu Shaomin, 2007, Cost Engineering, 49, 30
  3. Müller-Steinhagen H., 2000, “Handbook heat exchanger fouling: mitigation and cleaning technologies.”
  4. Müller-Steinhagen H., 2000, Berichte zur Energie- und Verfahrenstechnik, 1
  5. Hong Yu., 2007, “Composite fouling on heat exchanger surfaces.”
  6. Tchobanoglous G.F.L. Burton, 2003, “Waste water engineering.”
  7. Hasson D., 1962, DECHE-MA Monogr., 47, 233
  8. Augustin W., 1992, Verkrustung (fouling) von wärmeübertragungsflächen
  9. Middis J., 1994, Heat transfer and pressure drop for flowing wood pulp fibre suspensions
  10. Comstock Mathew C., 1999, “Literature review for application of fault detection and diagnostic method to vapor compression cooling equipment.”
  11. Reddy T Agami, 2006, “Draft final report: evaluation and assessment of fault detection and diagnostic methods for centrifugal chiller-phase II.”
  12. Reddy T Agami, 2001, “Final report: development and comparison of on-line model training techniques for model-based FDD method applied to vapor compression chiller.”
  13. Piper James E., 1999, “Operation and maintenance manual for energy management.”
  14. Comstock MC, 2002, ASHRAE Trans, 108
  15. Tatara R.A., 2000, ASHRAE Winter Meeting Dallas. ASHRAE Transactions, 106
  16. Tatara R.A., 2000, ASHRAE Winter Meeting Dallas. ASHRAE Transactions, 106
  17. Jones D., 2005, Energy efficient cooling, RAC seminar.
  18. Butler D., 1993, Proceedings of institute of refrigeration seminar, refrigerants beyond the crisis;
  19. Trust Carbon, 2009, “Top tips – extra tips for industrial companies.”
  20. Stouppe DE, 1989, National Engineer, 93, 14
  21. Gesellschaft VDI, 2010, “VDI Heat Atlas.”

Cited by

See all 16

Metadata

Authors
Firdaus, N., Prasetyo, B. T., & Luciana, T.
Affiliations
National Institute of Science and Technology (ID)
Venue
Energy Engineering
Published
2016-04-22
Volume
113
Issue
4
Pages
55-80
ISSN
  • 0199-8595 (ISSN-L)
  • 1546-0118
OpenAlex
W2342746964
Cited by
16
References
27
Citations by year
2026: 1 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 5 · 2018: 3 · 2017: 1
FWCI
2.67
Type
journal article
Language
en
Open access
closed
Locations
Energy Engineering (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Safety, Risk, Reliability and Quality › Reliability and Maintenance Optimization
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
Keywords
centrifugal chiller, maintenance optimization, maintenance intervals, energy efficiency, performance monitoring, failure modes, maintenance strategy, hotel HVAC, energy cost reduction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.