Chiller: Performance Deterioration and Maintenance
The DOI matches its Crossref record; 26 of the 27 references it cites were found in a registry or an index.
Abstract
Most energy efficiency programs focus on retrofitting or upgrading the equipment. As a matter of fact, maintenance is also a source of energy efficiency improvement. In this article, the performance deterioration of a centrifugal chiller in a hotel is investigated. The result shows that chiller performance deteriorates over time. To restore chiller performance, maintenance actions should be taken.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
(1992) · Waste Management · doi:10.1016/0956-053x(92)90028-h · Cited by 426
Maintenance, Replacement, and Reliability: Theory and Applications
Jardine, A. K. S., & Tsang, A. (1973) · PolyU Institutional Research Archive (Hong Kong Polytechnic University) · Cited by 387
Fouling of heat transfer surfaces
Bohnet, M. (1987) · Chemical Engineering & Technology · doi:10.1002/ceat.270100115 · Cited by 226
Common Faults and Their Impacts for Rooftop Air Conditioners
Breuker, M. S., & Braun, J. E. (1998) · HVAC&R Research · doi:10.1080/10789669.1998.10391406 · Cited by 195
Handbook of water and energy management in food processing
Klemeš, J. J., Smith, R., & Kim, J. (2008) · Woodhead Publishing Limited eBooks · doi:10.1533/9781845694678 · Cited by 142
Fault diagnosis and refrigerant leak detection in vapour compression refrigeration systems
Tassou, S. A., & Grace, I. N. (2005) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2004.12.007 · Cited by 128
Analysis of ‘classical’ deposition rate law for crystallisation fouling
Bansal, B., Chen, X. D., & Muller-Steinhagen, H. M. G. (2007) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2007.03.016 · Cited by 126
Scaling of Heat Exchanger Tubes by Calcium Carbonate
Watkinson, A. P., & Martinez, O. (1975) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.3450419 · Cited by 79
Facility management practices in higher education buildings
Lavy, S. (2008) · Journal of Facilities Management · doi:10.1108/14725960810908163 · Cited by 68
Complex Modal Analysis of a Flat Belt Pulley System With Belt Damping and Coulomb-Damped Tensioner
Kraver, T. C., Fan, G. W., & Shah, J. J. (1996) · Journal of Mechanical Design · doi:10.1115/1.2826885 · Cited by 66
Optimum cleaning cycles for heat transfer equipment undergoing fouling and ageing
Ishiyama, E. M., Paterson, W. R., & Wilson, D. I. (2010) · Chemical Engineering Science · doi:10.1016/j.ces.2010.10.036 · Cited by 61
Ritter, R. B. (1983) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.3245588 · Cited by 54
Benchmarking operation and maintenance costs of luxury hotels
Lai, J. H. K., & Yik, F. W. H. (2008) · Journal of Facilities Management · doi:10.1108/14725960810908145 · Cited by 52
Reitzer, B. J. (1964) · Industrial & Engineering Chemistry Process Design and Development · doi:10.1021/i260012a013 · Cited by 49
System performance characteristics of an air conditioner over a range of charging conditions
Farzad, M., & O’Neal, D. L. (1991) · International Journal of Refrigeration · doi:10.1016/0140-7007(91)90027-e · Cited by 47
Energy Management and Efficiency for the Process Industries
(2015) · Wiley eBooks · doi:10.1002/9781119033226 · Cited by 42
Reliability-Based Maintenance Strategies for Heat Exchangers Subject to Fouling
Sheikh, A. K., Zubair, S. M., Haq, M. U., et al. (1996) · Journal of Energy Resources Technology · doi:10.1115/1.2793878 · Cited by 33
Gordon, J. M., & Ng, K. C. (2000) · Cited by 29
Sheikh, A. (2000) · Energy · doi:10.1016/s0360-5442(99)00081-x · Cited by 24
Maintenance risk reduction for effective facilities management
Chandrashekaran, A., & Gopalakrishnan, B. (2008) · Journal of Facilities Management · doi:10.1108/14725960810847468 · Cited by 21
Tatara, R. A., & Payvar, P. (2000) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 16
Ratio of Operating and Maintenance Costs to Initial Costs of Building Services Systems
Wu, S., & Clements-Croome, D. J. (2007) · Kent Academic Repository (University of Kent) · Cited by 14
Saththasivam, J., TANG, G., & Ng, K. C. (2010) · International Journal of Air-Conditioning and Refrigeration · doi:10.1142/s2010132510000071 · Cited by 7
Measuring Instruments in Chiller Plants and Uncertainties in Performance Evaluation
Yik, F. W. H., & Chiu, T.-C. (1998) · HKIE Transactions · doi:10.1080/1023697x.1998.10667770 · Cited by 6
In-situ diagnosis of vapor-compressed chiller performance for energy saving
Shin, Y., Kim, Y., Moon, G.-W., et al. (2005) · Journal of Mechanical Science and Technology · doi:10.1007/bf03023943 · Cited by 3
Aging assessment of essential HVAC chillers used in nuclear power plants. Phase 1, Volume 1
Nuclear Regulatory Commission, W., Blahnik, D., Nuclear Regulatory Commission, W., et al. (1993) · doi:10.2172/10186028 · Cited by 2
Research works printed but not linked: 21
- Evans R., 1998, “The Long Term Costs of Owning and Using Buildings.”
- Wu Shaomin, 2007, Cost Engineering, 49, 30
- Müller-Steinhagen H., 2000, “Handbook heat exchanger fouling: mitigation and cleaning technologies.”
- Müller-Steinhagen H., 2000, Berichte zur Energie- und Verfahrenstechnik, 1
- Hong Yu., 2007, “Composite fouling on heat exchanger surfaces.”
- Tchobanoglous G.F.L. Burton, 2003, “Waste water engineering.”
- Hasson D., 1962, DECHE-MA Monogr., 47, 233
- Augustin W., 1992, Verkrustung (fouling) von wärmeübertragungsflächen
- Middis J., 1994, Heat transfer and pressure drop for flowing wood pulp fibre suspensions
- Comstock Mathew C., 1999, “Literature review for application of fault detection and diagnostic method to vapor compression cooling equipment.”
- Reddy T Agami, 2006, “Draft final report: evaluation and assessment of fault detection and diagnostic methods for centrifugal chiller-phase II.”
- Reddy T Agami, 2001, “Final report: development and comparison of on-line model training techniques for model-based FDD method applied to vapor compression chiller.”
- Piper James E., 1999, “Operation and maintenance manual for energy management.”
- Comstock MC, 2002, ASHRAE Trans, 108
- Tatara R.A., 2000, ASHRAE Winter Meeting Dallas. ASHRAE Transactions, 106
- Tatara R.A., 2000, ASHRAE Winter Meeting Dallas. ASHRAE Transactions, 106
- Jones D., 2005, Energy efficient cooling, RAC seminar.
- Butler D., 1993, Proceedings of institute of refrigeration seminar, refrigerants beyond the crisis;
- Trust Carbon, 2009, “Top tips – extra tips for industrial companies.”
- Stouppe DE, 1989, National Engineer, 93, 14
- Gesellschaft VDI, 2010, “VDI Heat Atlas.”
Cited by
On-edge multi-task transfer learning: model and practice with data-driven task allocation
Chen, Q., Zheng, Z., Hu, C., Wang, D., & Liu, F. (2020) · IEEE Transactions on Parallel and Distributed Systems · doi:10.1109/tpds.2019.2962435 · Cited by 88
“well-known fact that COP degrades over time [38], [39], COP also fluctuates markedly over different cooling loads and environmental conditions [15], which makes it exceedingly difficult to capture within an analytical model.”
BackgroundData Driven Chiller Sequencing for Reducing HVAC Electricity Consumption in Commercial Buildings
Zheng, Z., Chen, Q., Fan, C., Guan, N., Vishwanath, A., Wang, D., & Liu, F. (2018) · ACM International Conference on Future Energy Systems (e-Energy) · doi:10.1145/3208903.3208913 · Cited by 41
“Intuitively, the chiller demands exhibit distinctive temporal characteristics: 1) cooling loads of chillers are different in different seasons, especially summer and winter, which leads to varying performance degradation; 2) as chillers age, its performance gradually degrades as well [10].”
BackgroundMaintenance strategies and energy efficiency: a review
Firdaus, N., Ab-Samat, H., & Prasetyo, B. T. (2023) · Journal of Quality in Maintenance Engineering · doi:10.1108/jqme-06-2021-0046 · Cited by 41
Self-citationMaintenance for Energy efficiency: A Review
Firdaus, N., Ab-Samat, H., & Mohamad, N. (2019) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/530/1/012047 · Cited by 39
“By finding an optimal interval for condenser cleaning, there would be large energy savings potential [15].”
BackgroundResultInfluentialSelf-citationZheng, Z., Chen, Q., Fan, C., Guan, N., Vishwanath, A., Wang, D., & Liu, F. (2019) · IEEE Transactions on Sustainable Computing · doi:10.1109/tsusc.2019.2932045 · Cited by 21
“shown that over 12 months, there was a 20 percent reduction in the chilled water flow rate, caused by excessive fouling that blocked the tubes in the chiller condenser [10].”
Background
Metadata
- Authors
- Firdaus, N., Prasetyo, B. T., & Luciana, T.
- Affiliations
- National Institute of Science and Technology (ID)
- ORCID
- Firdaus, Nofirman
- Venue
- Energy Engineering
- Publisher
- Tech Science Press
- Published
- 2016-04-22
- Volume
- 113
- Issue
- 4
- Pages
- 55-80
- ISSN
- 0199-8595 (ISSN-L)
- 1546-0118
- OpenAlex
- W2342746964
- Semantic Scholar
- 4a5e3200a47dd81052f01cc5285cbf4617ac850f
- Cited by
- 16
- References
- 27
- Citations by year
- 2026: 1 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 5 · 2018: 3 · 2017: 1
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Energy Engineering (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Safety, Risk, Reliability and Quality › Reliability and Maintenance Optimization
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- centrifugal chiller, maintenance optimization, maintenance intervals, energy efficiency, performance monitoring, failure modes, maintenance strategy, hotel HVAC, energy cost reduction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.