Effect of stage duration on physiological variables commonly used to determine maximum aerobic performance during cycle ergometry
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In this study, we examined the effect of stage duration on physiological variables commonly used to determine maximum aerobic performance during cycle ergometry. Ten recreationally trained males (mean age 27.8 +/- 7.1 years; BMI 24.3 +/- 2.5 kg x m(-2); VO2max 52.5 +/- 5.9 ml x kg(-1) x min(-1)) performed three different stage duration protocols on two separate occasions. Each short stage (SS; 1-min stages), long stage (LS; 3-min stages), and constant load + short stage (CL + SS; 4-min constant load followed by 1-min stages) protocol started at 50 W with increments of 30 W. The physiological variables measured included: time to maximum, maximum workload, maximum oxygen consumption (VO2max), maximum heart rate, maximum rating of perceived exertion, maximum blood lactate concentration, and maximum respiratory exchange ratio. The ventilatory threshold was calculated for every trial of the three protocols. There was no difference in VO2max, but maximum heart rate was higher in the LS protocol (P<0.05). Maximum respiratory exchange ratio varied between the protocols (P<0.05), while maximum workload differed between the SS and LS protocols, and the LS and CL + SS protocols (P<0.0001). The physiological variables were comparable between trials for the SS and CL + SS protocols, but maximum workload and VO2max differed for the LS protocol (P<0.05). Workload at the ventilatory threshold was lower for the LS protocol (P<0.05). Heart rate at the ventilatory threshold was different between the LS and CL + SS protocols (P<0.05). Performing a test involving 1- or 3-min stage durations on a single occasion was appropriate for the determination of VO2max and the ventilatory threshold. However, the disparity in heart rate and workload could result in differences in mechanical and physiological work being undertaken. Consistent use of a protocol may alleviate errors during exercise prescription.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Criteria for maximal oxygen uptake: review and commentary
HOWLEY, E. T., BASSETT, D. R., & WELCH, H. G. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199509000-00009 · Cited by 1,656
Validity and reliability of combining three methods to determine ventilatory threshold
GASKILL, S. E., RUBY, B. C., WALKER, A. J., SANCHEZ, O. A., SERFASS, R. C., & LEON, A. S. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00007 · Cited by 444
Cited by
The specificity of training prescription and physiological assessment: A review
Reilly, T., Morris, T., & Whyte, G. (2009) · Journal of Sports Sciences · doi:10.1080/02640410902729741 · Cited by 283
“Alternative methods employed to establish relative aerobic and anaerobic contributions to performance include: the critical power concept (Moritani, Nagata, de Vries, & Muro, 1981 ); the accumulated oxygen deficit (Medbo, Mohn, Tabata, Bahr, & Sejersted, 1988 ); and direct methods employing measurements of oxygen cons…”
MethodDetermination of Second Lactate Threshold Using Near-infrared Spectroscopy in Elite Cyclists
Salas-Montoro, J.-A., Mateo-March, M., Sánchez-Muñoz, C., & Zabala, M. (2022) · International Journal of Sports Medicine · doi:10.1055/a-1738-0252 · Cited by 27
“If the cyclist did not complete the step but completed more than half, the proportional part of power corresponding to half a step was added [30].”
Background(2012) · Europe PMC (PubMed Central) · Cited by 23
Metadata
- Authors
- Roffey, D. M., Byrne, N. M., & Hills, A. P.
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2007-10
- Volume
- 25
- Issue
- 12
- Pages
- 1325-1335
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W1494655153
- Cited by
- 41
- References
- 3
- FWCI
- 7.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.