Validity and reliability of the Cortex MetaMax3B portable metabolic system
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Portable indirect calorimetry systems offer the advantage of field-based measurements, but manufacturers rarely provide data about validity or reliability. In this study, we evaluated the validity and reliability of the Cortex MetaMax3B portable metabolic system. Validity was determined by comparing MetaMax3B results against those from a first-principles metabolic calibrator and an automated Douglas bag system. Reliability was obtained from duplicate exercise tests completed by eight athletes. Participants completed three identical incremental rowing tests on a Concept2 ergometer; two tests used the MetaMax3B and one test used the Douglas bag system. Compared with the metabolic calibrator, the MetaMax3B results were within 0.20 litres . min(-1) (7.8%) and 6.15 litres . min(-1) (4.0%) for [Vdot]O(2) and V(E), respectively. During exercise, the MetaMax3B results were within 0.16 litres . min(-1) (4.1%; [Vdot]O(2)), 0.32 litres . min(-1) (7.7%; [Vdot]CO(2)), and 3.22 litres . min(-1) (4.9%; V(E)) compared with the Douglas bag system. The MetaMax3B results were significantly higher for [Vdot]O(2) (P = 0.03) and [Vdot]CO(2) (P < 0.001). The typical error from duplicate exercise tests using the MetaMax3B ranged from 2.0% ([Vdot]O(2)) to 3.6% (V(E)). Our results show that the MetaMax3B provides reliable measurements of metabolic demand with adequate validity for field-based measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635 · cited 1×
“The reliability of repeated MetaMax3B measurements was also established using typical errors (Hopkins, 2000).”
MethodAccuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems
Crouter, S. E., Antczak, A., Hudak, J. R., DellaValle, D. M., & Haas, J. D. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0255-0 · Cited by 240 · cited 14×
“E-mail: tony.rice@ausport.gov.au ISSN 0264-0414 print/ISSN 1466-447X online 2010 Taylor & Francis DOI: 10.1080/02640410903582776 measurements with both machines (Crouter et al., 2006; Duffield et al., 2004; Larsson et al., 2004; Prieur et al., 2003).”
BackgroundMethodResultInfluential
Cited by
Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis system
Macfarlane, D. J., & Wong, P. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2230-7 · Cited by 167
“The relatively large percentage errors reported in our study for VO2 and VE by the MM3B are generally higher than those reported in the above validation studies, and also exceed the 4–10% guidelines recommended by some (Brehm et al. 2004; Laurent et al. 2008; Vogler et al. 2010), although these limits are not universa…”
BackgroundMethodResultInfluentialWahl, Y., Düking, P., Droszez, A., Wahl, P., & Mester, J. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00725 · Cited by 133
Energy system contribution during competitive cross-country skiing
Losnegard, T. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04158-x · Cited by 99
Validity and Reliability of the VO2 Master Pro for Oxygen Consumption and Ventilation Assessment
(2020) · International Journal of Exercise Science · doi:10.70252/thjt1177 · Cited by 39
Metadata
- Authors
- Vogler, A. J., Rice, A. J., & Gore, C. J.
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2010-05
- Volume
- 28
- Issue
- 7
- Pages
- 733-742
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W2171054811
- Cited by
- 134
- References
- 3
- FWCI
- 13.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity and reliability of the Cortex MetaMax3B portable metabolic system. https://app.cochat.ai/papers/10.1080/02640410903582776
- The paper
- Vogler, A. J., Rice, A. J., & Gore, C. J. (2010). Validity and reliability of the Cortex MetaMax3B portable metabolic system. Journal of Sports Sciences. https://doi.org/10.1080/02640410903582776
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.