Is intracellular hyperthermia superior to extracellular hyperthermia in the thermal sense?
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
More than 20 years ago, it was hypothesized that intracellular hyperthermia is superior to extracellular hyperthermia. It was further hypothesized that even a single biological cell containing magnetic nanoparticles can be treated for hyperthermia by an AC magnetic field, independent of its surrounding cells. Since experimental investigation of the thermal effects of intracellular hyperthermia is not feasible, these hypotheses have been studied theoretically. The current report shows that nano-scale heating effects are negligible. This study further shows that intracellular heat generation is sufficient to create the necessary conditions for hyperthermia only in a large group of cells loaded with nanoparticles, having an overall diameter of at least 1mm. It is argued in this report that there is no reason to believe that intracellular hyperthermia is superior to extracellular hyperthermia in the thermal sense.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carslaw, H. S., & Jaeger, J. C. (1947) · International Linear Collider · Cited by 21,232
Microscale Heat Conduction in Dielectric Thin Films
Majumdar, A. (1993) · Journal of Heat Transfer · doi:10.1115/1.2910673 · Cited by 910 · cited 1×
“It can be calculated from equation (10) that a minimal diameter of 0.”
BackgroundPhysical limits of hyperthermia using magnetite fine particles
Hergt, R., Andra, W., d'Ambly, C. G., Hilger, I., Kaiser, W. A., Richter, U., & Schmidt, H.-G. (1998) · IEEE Transactions on Magnetics · doi:10.1109/20.718537 · Cited by 658
Jordan, A., Scholz, R., Wust, P., Schirra, H., Schiestel, T., Schmidt, H., & Felix, R. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(98)00558-7 · Cited by 521 · cited 3×
“It can further be calculated from equation (6) that a minimal diameter of 1.”
BackgroundMethodInfluentialArrhenius relationships from the molecule and cell to the clinic
Dewey, W. C. (1994) · International Journal of Hyperthermia · doi:10.3109/02656739409009351 · Cited by 501
Gordon, R. T., Hines, J. R., & Gordon, D. (1979) · Medical Hypotheses · doi:10.1016/0306-9877(79)90063-x · Cited by 310 · cited 2×
“Under these conditions, equations (1)±(3) are still valid when substituting the nanoparticle diameter, Dp, with the cell diameter, Dc.”
BackgroundJordan, A., Wust, P., Scholz, R., Tesche, B., Fähling, H., Mitrovics, T., Vogl, T., Cervós-navarro, J., & Felix, R. (1996) · International Journal of Hyperthermia · doi:10.3109/02656739609027678 · Cited by 259 · cited 2×
“For magnetic nanoparticle design purposes, equation (4) can be rearranged to ®nd the minimal heating power required for hyperthermia in a single cell, which yields the minimal volumetric heat generation required in the particles.”
BackgroundAndrä, W., d'Ambly, C. G., Hergt, R., Hilger, I., & Kaiser, W. A. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(98)00552-6 · Cited by 226 · cited 2×
“The special solution at the centre of the target region, equation (9), is presented graphically in ®gure 2.”
BackgroundInduction of apoptotic cell DNA fragmentation in human cells after treatment with hyperthermia
Fairbairn, J. J., Khan, M. W., Ward, K. J., Loveridge, B. W., Fairbairn, D. W., & O'Neill, K. L. (1995) · Cancer Letters · doi:10.1016/0304-3835(94)03668-9 · Cited by 65 · cited 3×
“Under these conditions, equations (1)±(3) are still valid when substituting the nanoparticle diameter, Dp, with the cell diameter, Dc.”
BackgroundEffects of Hyperthermia on Intracellular Chloride
Amorino, G. P., & Fox, M. H. (1996) · The Journal of Membrane Biology · doi:10.1007/s002329900099 · Cited by 20 · cited 1×
“The solution of equation (5) for zero initial condition in an in®nite domain is given by Carslaw and Jaeger(12), which has been recompiled in the following dimensionless form:”
Method
Cited by
Applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Magnetic nanoparticle design for medical diagnosis and therapy
Mornet, S., Vasseur, S., Grasset, F., & Duguet, E. (2004) · Journal of Materials Chemistry · doi:10.1039/b402025a · Cited by 1,745
Progress in applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Thanh, N. T. K., Jones, S. K., & Dobson, J. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/22/224001 · Cited by 1,455
Magnetic particle hyperthermia: nanoparticle magnetism and materials development for cancer therapy
Hergt, R., Dutz, S., Müller, R., & Zeisberger, M. (2006) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/18/38/s26 · Cited by 977
Metadata
- Authors
- Rabin, Y.
- Venue
- International Journal of Hyperthermia
- Publisher
- Informa UK Limited
- Published
- 2002-01
- Volume
- 18
- Issue
- 3
- Pages
- 194-202
- ISSN
- 0265-6736 (ISSN-L)
- 1464-5157
- OpenAlex
- W2002819872
- Cited by
- 212
- References
- 10
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.