CoChat

Assessment of Differing Definitions of Accelerometer Nonwear Time

Open access
Evenson, Kelly R., Terry, James W. · 2009 · Research Quarterly for Exercise and Sport
Cited by 121

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Measuring physical activity with objective measures, such as accelerometers, is becoming more common with researchers, as evidenced through the increasing number of research articles using accelerometers (R Troiano, 2005). Accelerometers measure acceleration multiple times within a given frequency and summarize this as a count over a pre-specified time period or epoch. The resultant count represents acceleration over the epoch length. Accelerometers are advantageous because they eliminate language or literacy difficulties, recall bias, and social desirability bias present with self-report measures of physical activity. With the increasingly widespread use of accelerometers, standardization of how the data are collected, cleaned, and reported across studies would be useful. In 2005, Masse et al (Masse et al., 2005) identified five methodological issues regarding accelerometer data reduction, the process of reducing the data in order to derive summary measures. These included (1) identifying wearing time of the accelerometer, (2) defining minimal wear time for a valid day, (3) identifying spurious data, (4) computing summary variables and aggregating days of data, and (5) extracting bouts of activity. This paper focuses on the first issue, namely identifying nonwearing time of the accelerometer. Understanding whether the accelerometer is being worn is used to assess compliance and to determine if the participant’s data will contribute to the resultant analyses. Defining wearing and nonwearing time also affects the derivation of summary physical activity measures based on this time, such as average counts per hour worn or minutes in sedentary, light, moderate, or vigorous activity (Corder, Brage, & Ekelund, 2007). How to define and assess nonwearing time of the accelerometer is not currently standardized across research studies. Participants are typically instructed to wear the accelerometer during all waking hours and to remove the device for showering or swimming activities, although some devices are now waterproof. The challenge is that participants often take the accelerometer off for other personal reasons. When an accelerometer such as an ActiGraph or an Actical is not being worn, it will typically register as zero counts over the epoch. However, it is possible for a person to be still (such as sleeping or sitting without movement), while wearing the accelerometer, and also register zero counts over the epoch. This can occur for multiple minutes at a time and are likely more common among those who are very sedentary throughout the day. Some have recommended that participants keep a log sheet to help determine when the participant is not wearing the monitor (Esliger, Copeland, Barnes, & Tremblay, 2005; Trost, McIver, & Pate, 2005). The challenge with this approach is that the process of keeping a log introduces a self-reporting aspect of data collection and compliance can be hampered. For this reason the use of a log was included for the National Health and Nutrition Examination Survey (NHANES) pilot study and subsequently dropped for the deployment into the main study in 2003-04 (R Troiano, 2006; RP Troiano et al., 2008). An alternative to a log kept by participants is to deduce the most reasonable nonwearing time based on the accelerometer data. This approach is more commonly used by researchers. Some recent studies of youth and adults utilizing the ActiGraph have, for example, used 10 minutes (Brage et al., 2004; Ekelund, Yngve, Brage, Westerterp, & Sjostrom, 2004; Riddoch et al., 2004), 15 minutes (Rousham, Clarke, & Gross, 2005), 20 minutes (Jilcott, Evenson, Laraia, & Ammerman, 2007; Savitz et al., 2006; Treuth et al., 2004), 30 minutes, or 60 minutes (Matthews et al., 2008; RP Troiano et al., 2008) to define the timespan of zeros on the accelerometer to indicate nonwearing time. Many other studies do not indicate how nonwearing time is defined. Dr. Masse and colleagues (Masse et al., 2005) explored the effect of differing definitions of nonwearing time on results, comparing 20 minutes and 60 minutes of consecutive zeros as an indicator of nonwearing time among a sample of 40 to 70 year old African American and Hispanic women. However, in the same analyses this study also varied other accelerometer data reduction decisions, making the interpretation of the influence of the varying of nonwear time only difficult. The purpose of this study was to describe the effect of changing the definition of accelerometer nonwear time on an aggregated sample of participants, prior to using the data to analyze physical activity by individuals, and to assist others in replicating this process. To do this, we utilized data from the third Pregnancy, Infection, and Nutrition (PIN3) Postpartum Study, which collected accelerometer data on women at 3- and 12-months postpartum.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/02701367.2009.10599570

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 121

Metadata

Authors
Evenson, K. R., & Terry, J. W.
Venue
Research Quarterly for Exercise and Sport
Published
2009-06
Volume
80
Issue
2
Pages
355-362
ISSN
  • 0034-5377 (ISSN-L)
  • 0270-1367
  • 2168-3824
OpenAlex
W2099521439
Cited by
121
References
4
FWCI
2.95
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of Differing Definitions of Accelerometer Nonwear Time. https://app.cochat.ai/papers/10.1080/02701367.2009.10599570
The paper
Evenson, K. R., & Terry, J. W. (2009). Assessment of Differing Definitions of Accelerometer Nonwear Time. Research Quarterly for Exercise and Sport. https://doi.org/10.1080/02701367.2009.10599570

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.