CoChat

Penetration of Particles into Buildings and Associated Physical Factors. Part I: Model Development and Computer Simulations

Open access
Thornburg, J., Ensor, D. S., Rodes, C. E., Lawless, P. A., Sparks, L. E., Mosley, R. B. · 2001 · Aerosol Science and Technology
Cited by 101

The DOI matches its Crossref record.

Abstract

The PM2.5 standard proposed by the U.S. Environmental Protection Agency (EPA) has stimulated research on the relationships between particulate matter concentrations and the exposures and subsequent health responses of sensitive subpopulations, such as the elderly. Since individuals in these subpopulations may spend more than 90% of their time indoors, understanding the relationship between outdoor particle concentrations and those found in indoor microenvironments is critical. This research resulted in a time-dependent indoor air quality model incorporating all potential particle sources and loss mechanisms. Monte Carlo simulations of the model identified the mechanisms, such as particle loss during penetration through the building envelope, that modify the outdoor particle size distribution during transport into the interior of a building, calculated indoor-to-outdoor (I/O) concentration ratios, and estimated penetration factors as a function of particle size. Indoor particle generation and transport of outdoor particles through the HVAC system were the most important contributors to the indoor concentration in residential and commercial buildings, respectively. The most significant removal mechanisms included ventilation through and particle removal by the HVAC filter if an HVAC system was present, or particle deposition on indoor surfaces if an HVAC system was not present. The modeled I/O concentration ratios varied between 0.05 and 0.5, depending on particle size and type of ventilation system, and agreed well with published experimental results. Penetration factors less than unity were calculated for particles with aerodynamic diameters larger than 0.2 θ m if the air exchange rate and steady-state I/O concentration ratio were correlated during the simulations. An additional correlation between the air exchange rate and particle deposition velocity is required if penetration factors less than unity are to be modeled for particles with aerodynamic diameters smaller than 0.2 θ m. These results

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/02786820119886

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 101

Metadata

Authors
Thornburg, J., Ensor, D. S., Rodes, C. E., Lawless, P. A., Sparks, L. E., & Mosley, R. B.
Venue
Aerosol Science and Technology
Published
2001-01
Volume
34
Issue
3
Pages
284-296
ISSN
  • 0278-6826 (ISSN-L)
  • 1521-7388
OpenAlex
W2113730536
Cited by
101
References
0
FWCI
3.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Penetration of Particles into Buildings and Associated Physical Factors. Part I: Model Development and Computer Simulations. https://app.cochat.ai/papers/10.1080/02786820119886
The paper
Thornburg, J., Ensor, D. S., Rodes, C. E., Lawless, P. A., Sparks, L. E., & Mosley, R. B. (2001). Penetration of Particles into Buildings and Associated Physical Factors. Part I: Model Development and Computer Simulations. Aerosol Science and Technology. https://doi.org/10.1080/02786820119886

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.