Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 194

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Consistency and Traceability of Black Carbon Measurements Made by Laser-Induced Incandescence, Thermal-Optical Transmittance, and Filter-Based Photo-Absorption Techniques

Open access
Kondo, Y., Sahu, L., Moteki, N., Khan, F., Takegawa, N., Liu, X., Koike, M., Miyakawa, T.·2011·Aerosol Science and Technology

Abstract

In this study, we show that black carbon (BC) mass concentrations measured by different techniques are consistent and traceable. First, we present the volatilities of 13 organic compounds passed through a heated inlet. These data were used to quantify the interference of organic aerosols on the BC measurement techniques. The masses of the refractory particles that incandesce (m*ref) were used to calibrate BC mass measured by a single-particle soot photometer (SP2), which uses laser-induced incandescence. This calibration was influenced little by refractory organics and agreed well with that of fullerene soot, which indicates the consistency of the standards. We estimated the interference of pyrolyzed refractory organics on the BC measured with a filter-based absorption photometer continuous soot monitoring system (COSMOS) with a heated inlet to be small in Asia. This was also confirmed by the stable mass absorption cross section (MAC) obtained by the high correlations between BC mass concentrations measured by COSMOS (M COSMOS) and those measured by the thermal-optical transmittance method (M TOT) (CitationKondo et al. 2009). M COSMOS was also compared with total BC mass concentrations measured with an SP2 (M SP2) in Tokyo in 2009. M COSMOS and M SP2 were highly correlated (r 2= 0.97) and agreed to within about 10% on average. These results demonstrate that M SP2, M COSMOS, and M TOT were nearly identical. Use of the masses of incandescing refractory BC particles for calibration of BC mass concentrations determined by different techniques gave consistent results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/02786826.2010.533215

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 194

Metadata

Authors
Kondo, Y., Sahu, L., Moteki, N., Khan, F., Takegawa, N., Liu, X., Koike, M., & Miyakawa, T.
Venue
Aerosol Science and Technology
Published
2011-02
Volume
45
Issue
2
Pages
295-312
ISSN
  • 0278-6826 (ISSN-L)
  • 1521-7388
OpenAlex
W2055381129
Cited by
194
References
2
FWCI
8.91
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Consistency and Traceability of Black Carbon Measurements Made by Laser-Induced Incandescence, Thermal-Optical Transmittance, and Filter-Based Photo-Absorption Techniques. https://app.cochat.ai/papers/10.1080/02786826.2010.533215
The paper
Kondo, Y., Sahu, L., Moteki, N., Khan, F., Takegawa, N., Liu, X., Koike, M., & Miyakawa, T. (2011). Consistency and Traceability of Black Carbon Measurements Made by Laser-Induced Incandescence, Thermal-Optical Transmittance, and Filter-Based Photo-Absorption Techniques. Aerosol Science and Technology. https://doi.org/10.1080/02786826.2010.533215

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.