The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
On the Performance of the Berner Low Pressure Impactor
Open accessAbstract
Particle collection characteristics of the compressible flow stages 1–6 of the Berner low-pressure impactor (BLPI, Hauke Aeras 25-4/0.015) have been studied. A new, real-time impactor stage efficiency measurement system has been developed. It is based on the use of two electrometers, one connected to the collection plate of the impactor, and the other to the backup filter. This method is used with singly charged, monodisperse dioctyl phthalate (DOP) particles to determine the shape of the collection efficiency curves of the BLPI. In addition, particle collection characteristics have been studied using fluorometric analysis. A new method for substrate film greasing is also introduced. Experimental cut diameters of stages 1–6, as determined with DOP particles using electrical measurement method, are 0.034, 0.066, 0.094, 0.17, 0.33, and 0.55 /un. They are clearly larger than corresponding values given by the manufacturer. The average of the square root of the Stokes number at 50% collection efficiency, based on experimental cut diameters and evaluated at stage conditions, is 0.465. For solid ammonium fluorescein particles the collection efficiency of high-velocity stages (1–6) was poor, although the substrates (Mylar film) were greased with Apiezon L vacuum grease. Using experimentally determined stage pressures and calculated cut diameters it was established that the compressible flow stages of different units of the same BLPI model may have significantly different cut diameters. The effect of temperature and pressure on cutoff diameters at atmospheric conditions near ground level is also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aerosol classification by electric mobility: apparatus, theory, and applications
Knutson, E. O., & Whitby, K. T. (1975) · Journal of Aerosol Science · doi:10.1016/0021-8502(75)90060-9 · Cited by 1,395
Slip Correction Measurements of Spherical Solid Aerosol Particles in an Improved Millikan Apparatus
Allen, M. D., & Raabe, O. G. (1985) · Aerosol Science and Technology · doi:10.1080/02786828508959055 · Cited by 504
Characteristics of laminar jet impactors
Marple, V. A., & Liu, B. Y. H. (1974) · Environmental Science & Technology · doi:10.1021/es60092a003 · Cited by 293
Marple, V. A., & Willeke, K. (1976) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(76)90144-x · Cited by 282
An aerosol generator of high stability
LIU, B. Y. H., & LEE, K. W. (1975) · American Industrial Hygiene Association Journal · doi:10.1080/0002889758507357 · Cited by 218
Characteristics of the Berner Impactor for Sampling Inorganic Ions
Wang, H.-C., & John, W. (1988) · Aerosol Science and Technology · doi:10.1080/02786828808959179 · Cited by 161
Calibration studies of the drum impactor
Raabe, O. G., Braaten, D., Axelbaum, R. L., et al. (1988) · Journal of Aerosol Science · doi:10.1016/0021-8502(88)90222-4 · Cited by 97
Evaporation Rates of Monodisperse Organic Aerosols in the 0.02- to 0.2-μm-Diameter Range
Rader, D. J., McMurry, P. H., & Smith, S. M. (1987) · Aerosol Science and Technology · doi:10.1080/02786828708959137 · Cited by 63
Kauppinen, E. I., Hillamo, R., Ruuskanen, J., Hakkarainen, T., & Rouhiainen, P. (1986) · Journal of Aerosol Science · doi:10.1016/0021-8502(86)90145-x · Cited by 18
Self-citation
Cited by
Primary biological aerosol particles in the atmosphere: a review
Després, V. R., Huffman, J. A., Burrows, S. M., Hoose, C., Safatov, A. S., Buryak, G., Fröhlich-Nowoisky, J., Elbert, W., Andreae, M. O., Pöschl, U., et al. (2012) · Tellus B: Chemical and Physical Meteorology · doi:10.3402/tellusb.v64i0.15598 · Cited by 1,500
Nanoparticles and the Environment
Biswas, P., & Wu, C.-Y. (2005) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2005.10464656 · Cited by 793
Chow, J. C. (1995) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1995.10467369 · Cited by 701
Bardouki, H., Liakakou, H., Economou, C., Sciare, J., Smolı́k, J., Ždı́mal, V, Eleftheriadis, K., Lazaridis, M., Dye, C., & Mihalopoulos, N. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00859-2 · Cited by 291
Chemical composition and mass closure of particulate matter at six urban sites in Europe
Sillanpää, M., Hillamo, R., Saarikoski, S., Frey, A., Pennanen, A., Makkonen, U., Spolnik, Z., Van Grieken, R., Braniš, M., Brunekreef, B., et al. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.01.063 · Cited by 225
Self-citation
Metadata
- Authors
- Hillamo, R. E., & Kauppinen, E. I.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 1991-01
- Volume
- 14
- Issue
- 1
- Pages
- 33-47
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W2166661335
- Cited by
- 269
- References
- 9
- FWCI
- 14.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the Performance of the Berner Low Pressure Impactor. https://app.cochat.ai/papers/10.1080/02786829108959469
- The paper
- Hillamo, R. E., & Kauppinen, E. I. (1991). On the Performance of the Berner Low Pressure Impactor. Aerosol Science and Technology. https://doi.org/10.1080/02786829108959469
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.