Asymmetric Instrument Response Resulting from Mixing Effects in Accelerated DMA-CPC Measurements
Open accessThe DOI matches its Crossref record.
Abstract
Several method have been proposed to accelerate the measurements made with differential mobility analyzers (DMA), including the Scanning Electrical Mobility Spectrometer (SEMS) and the Scanning Mobility Particle Sizer (SMPS). Wang and Flagan (1990) developed a data analysis procedure that accounts for the migration of the particles through a time-varying electric field and the delay associated with transport from the analyzer column outlet to the detection point. Experience using a variety of detectors and scan rates has indicated that the instrument response depends on the plumbing configuration if a condensation particle counter (CPC) is used as a detector. When a sharply peaked distribution is analyzed, the apparent breadth of the measured distribution depends on the detector used and on the scan rate. Size distributions measured with an increasing voltage scan exhibit a tail toward large particle sizes, while decreasing voltage scans produce a more pronounced tail on the small particle end of the distribution. The reduction in peak height with increasing scan rate can be attributed to particle retention in the plumbing between the outlet of the DMA analyzer column and the point in the CPC where the particles are detected optically. This paper examines the smearing of the transfer function of the SEMS as a result of flow non-idealities in the system. A model has been developed to predict the distortion of the transfer function in terms of the particle residence time distribution within the instrument. Results of this model are compared with calibration data as a function of the detector employed and the scan rate. We include laboratory observations of the phenomenon and examine the use of data inversion techniques to retrieve the true size distribution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wiedensohler, A., Birmili, W., Nowak, A., Sonntag, A., Weinhold, K., Merkel, M., Wehner, B., Tuch, T., Pfeifer, S., Fiebig, M., et al. (2012) · Atmospheric Measurement Techniques · doi:10.5194/amt-5-657-2012 · Cited by 868
Giechaskiel, B., Maricq, M., Ntziachristos, L., Dardiotis, C., Wang, X., Axmann, H., Bergmann, A., & Schindler, W. (2014) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2013.09.003 · Cited by 299
Mobility particle size spectrometers: Calibration procedures and measurement uncertainties
Wiedensohler, A., Wiesner, A., Weinhold, K., Birmili, W., Hermann, M., Merkel, M., Müller, T., Pfeifer, S., Schmidt, A., Tuch, T., et al. (2018) · Aerosol Science and Technology · doi:10.1080/02786826.2017.1387229 · Cited by 190
“The “ DMA transfer function ” (Birmili et al. 1997; Collins et al. 2002; Hagwood et al. 1999; Knutson and Whitby 1975; Russell et al. 1995; Stolzenburg 1988; Zhang and Flagan 1996) can be described as a triangle selecting a range of electrical mobilities with an averaged transfer probability of 50%.”
Aerosol dynamics in ship tracks
(1999) · Journal of Geophysical Research: Atmospheres · doi:10.1029/1999jd900985 · Cited by 44
Self-citation
Metadata
- Authors
- Russell, L. M., Flagan, R. C., & Seinfeld, J. H.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 1995-01
- Volume
- 23
- Issue
- 4
- Pages
- 491-509
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W2073643487
- Cited by
- 92
- References
- 0
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Asymmetric Instrument Response Resulting from Mixing Effects in Accelerated DMA-CPC Measurements. https://app.cochat.ai/papers/10.1080/02786829508965332
- The paper
- Russell, L. M., Flagan, R. C., & Seinfeld, J. H. (1995). Asymmetric Instrument Response Resulting from Mixing Effects in Accelerated DMA-CPC Measurements. Aerosol Science and Technology. https://doi.org/10.1080/02786829508965332
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.