Asymmetric Instrument Response Resulting from Mixing Effects in Accelerated DMA-CPC Measurements

Open access
Russell, Lynn M., Flagan, Richard C., Seinfeld, John H. · 1995 · Aerosol Science and Technology
Cited by 92

The DOI matches its Crossref record.

Abstract

Several method have been proposed to accelerate the measurements made with differential mobility analyzers (DMA), including the Scanning Electrical Mobility Spectrometer (SEMS) and the Scanning Mobility Particle Sizer (SMPS). Wang and Flagan (1990) developed a data analysis procedure that accounts for the migration of the particles through a time-varying electric field and the delay associated with transport from the analyzer column outlet to the detection point. Experience using a variety of detectors and scan rates has indicated that the instrument response depends on the plumbing configuration if a condensation particle counter (CPC) is used as a detector. When a sharply peaked distribution is analyzed, the apparent breadth of the measured distribution depends on the detector used and on the scan rate. Size distributions measured with an increasing voltage scan exhibit a tail toward large particle sizes, while decreasing voltage scans produce a more pronounced tail on the small particle end of the distribution. The reduction in peak height with increasing scan rate can be attributed to particle retention in the plumbing between the outlet of the DMA analyzer column and the point in the CPC where the particles are detected optically. This paper examines the smearing of the transfer function of the SEMS as a result of flow non-idealities in the system. A model has been developed to predict the distortion of the transfer function in terms of the particle residence time distribution within the instrument. Results of this model are compared with calibration data as a function of the detector employed and the scan rate. We include laboratory observations of the phenomenon and examine the use of data inversion techniques to retrieve the true size distribution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/02786829508965332

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 92

Metadata

Authors
Russell, L. M., Flagan, R. C., & Seinfeld, J. H.
Venue
Aerosol Science and Technology
Published
1995-01
Volume
23
Issue
4
Pages
491-509
ISSN
  • 0278-6826 (ISSN-L)
  • 1521-7388
OpenAlex
W2073643487
Cited by
92
References
0
FWCI
1.85
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Asymmetric Instrument Response Resulting from Mixing Effects in Accelerated DMA-CPC Measurements. https://app.cochat.ai/papers/10.1080/02786829508965332
The paper
Russell, L. M., Flagan, R. C., & Seinfeld, J. H. (1995). Asymmetric Instrument Response Resulting from Mixing Effects in Accelerated DMA-CPC Measurements. Aerosol Science and Technology. https://doi.org/10.1080/02786829508965332

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.