Dispersive liquid–liquid microextraction and spectrophotometric determination of cobalt in water samples
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A new simple and rapid dispersive liquid–liquid microextraction has been applied to preconcentrate trace levels of cobalt as a prior step to its determination by spectrophotometric detection. In this method a small amount of chloroform as the extraction solvent was dissolved in pure ethanol as the disperser solvent, then the binary solution was rapidly injected by a syringe into the water sample containing cobalt ions complexed by 1-(2-pyridylazo)-2-naphthol (PAN). This forms a cloudy solution. The cloudy state was the result of chloroform fine droplets formation, which has been dispersed in bulk aqueous sample. Therefore, Co-PAN complex was extracted into the fine chloroform droplets. After centrifugation (2 min at 5000 rpm) these droplets were sedimented at the bottom of conical test tube (about 100 µL) and then the whole of complex enriched extracted phase was determined by a spectrophotometer at 577 nm. Complex formation and extraction are usually affected by some parameters, such as the types and volumes of extraction solvent and disperser solvent, salt effect, pH and the concentration of chelating agent, which have been optimised for the presented method. Under optimum conditions, the enhancement factor (as the ratio of slope of preconcentrated sample to that obtained without preconcentration) of 125 was obtained from 50 mL of water sample, and the limit of detection (LOD) of the method was 0.5 µg L−1and the relative standard deviation (RSD, n = 5) for 50 µg L−1 of cobalt was 2.5%. The method was applied to the determination of cobalt in tap and river water samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Berijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Cited by
Evolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2009) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2008.10.042 · Cited by 414
Anthemidis, A. N., & Ioannou, K.-I. G. (2009) · Talanta · doi:10.1016/j.talanta.2009.09.005 · Cited by 322
Dadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305
Arain, M. B., Yilmaz, E., & Soylak, M. (2016) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2016.10.005 · Cited by 168
Metadata
- Authors
- Gharehbaghi, M., Shemirani, F., & Baghdadi, M.
- Venue
- International Journal of Environmental Analytical Chemistry
- Publisher
- Informa UK Limited
- Published
- 2008-06-15
- Volume
- 88
- Issue
- 7
- Pages
- 513-523
- ISSN
- 0306-7319 (ISSN-L)
- 1029-0397
- OpenAlex
- W2118818138
- Cited by
- 83
- References
- 2
- FWCI
- 8.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dispersive liquid–liquid microextraction and spectrophotometric determination of cobalt in water samples. https://app.cochat.ai/papers/10.1080/03067310701809128
- The paper
- Gharehbaghi, M., Shemirani, F., & Baghdadi, M. (2008). Dispersive liquid–liquid microextraction and spectrophotometric determination of cobalt in water samples. International Journal of Environmental Analytical Chemistry. https://doi.org/10.1080/03067310701809128
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.