CoChat

Gas Chromatographic Trace-Level Determination of Volatile Organic Sulfides and Selenides and of Methyl Iodide in Atlantic Surface Water

Tanzer, D., Heumann, K. G. · 1992 · International Journal of Environmental Analytical Chemistry
Cited by 51

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The concentration of the sulfur compounds dimethyl sulfide (DMS), dimethyl disulfide (DMDS), and carbon disulfide (CS2) as well as of methyl iodide (CH3I) was determined in surface sea water of the Atlantic Ocean from 30°S to 45°N during an expedition with the German research vessel 'FS Polarstern' using a purge and trap/gas chromatographic system equipped with a flame photometric and an electron capture detector. The most abundant sulfur compound was DMS with a mean concentration of 55 ng S/l. DMDS and CS2 could be detected in 14 and 56 out of a total number of 100 sea water samples with concentrations up to 14.7 ng S/l and up to 10.7 ng S/l, respectively. This is the first time that DMDS could be quantified in a number of sea water samples. CH3I was determined in all samples with a mean of 0.6 ng I/l. In three Atlantic sea water samples dimethyl selenide (DMSe) was detected for the first time (concentration range, 1–5 ng Se/l). Its presence was verified by means of an atomic emission detector. DMSe was the only volatile selenium compound found. Contrary to CS2, the concentrations of CH3I and especially of DMS and DMDS are related to the levels of marine primary production. In agreement with this, the DMS concentrations correlated well with those of dimethyl sulfonium propionate (DMSP). However, no clear relationship between CH3I and DMS could be found, indicating a different pathway of biological production.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/03067319208027039

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 51

Metadata

Authors
Tanzer, D., & Heumann, K. G.
Venue
International Journal of Environmental Analytical Chemistry
Published
1992-06
Volume
48
Issue
1
Pages
17-31
ISSN
  • 0306-7319 (ISSN-L)
  • 1029-0397
OpenAlex
W1985508207
Cited by
51
References
2
FWCI
4.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gas Chromatographic Trace-Level Determination of Volatile Organic Sulfides and Selenides and of Methyl Iodide in Atlantic Surface Water. https://app.cochat.ai/papers/10.1080/03067319208027039
The paper
Tanzer, D., & Heumann, K. G. (1992). Gas Chromatographic Trace-Level Determination of Volatile Organic Sulfides and Selenides and of Methyl Iodide in Atlantic Surface Water. International Journal of Environmental Analytical Chemistry. https://doi.org/10.1080/03067319208027039

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.