Cited by 13Neurological disorders and treatmentsMotor Control and AdaptationParkinson's Disease Mechanisms and Treatments

A new method for selective measurement of joint movement in hand tremor in Parkinson's disease patients

Rozman, J., Bartolić, A., Ribarič, S.·2007·Journal of Medical Engineering & Technology

Abstract

Parkinson's disease (PD) is a progressive degenerative disorder of the central nervous system with tremor being one of its four main clinical features. Currently used methods can directly evaluate tremor amplitude and frequency but not joint movement in the affected limb. Measurement of joint movement facilitates the location of muscle groups that participate in PD tremor and this is important for treatment with local botulinum toxin injections. We developed and tested a method that measured tremor amplitude and frequency in a specific joint of the hand in PD patients. The tremor analysis method was based on force transducers adapted to record rest tremor of the wrist and metacarpophalangeal joints in two degrees of freedom for each joint. Direct measurements of joint movement in the hand can evaluate tremor amplitude and frequency and also locate the muscle groups that are most active in tremor movement, thus enabling their local treatment.

Integrity signals

Registry

Crossref · 10.1080/03091900600992064

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Rozman et al. have developed a method based on force transducers to evaluate rest tremor of the wrist and metacarpophalangeal joints in two degrees of freedom for each joint.

    “Rozman et al. have developed a method based on force transducers to evaluate rest tremor of the wrist and metacarpophalangeal joints in two degrees of freedom for each joint [50].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Rozman, J., Bartolić, A., & Ribarič, S.
Affiliations
University of Ljubljana (SI)
Corresponding author
Ribarič, S.
Venue
Journal of Medical Engineering & Technology
Published
2007-01
Volume
31
Issue
4
Pages
305-311
ISSN
  • 0309-1902 (ISSN-L)
  • 1464-522X
OpenAlex
W1966678408
Cited by
13
References
2
Citations by year
2025: 1 · 2024: 1 · 2020: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 2 · 2013: 1 · 2012: 1
FWCI
0.46
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Medical Engineering & Technology (publishedVersion)
  • PubMed (publishedVersion)
Funders
Uddannelses- og Forskningsministeriet
Topics
  • Health Sciences › Medicine › Neurology › Neurological disorders and treatments
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Health Sciences › Medicine › Neurology › Parkinson's Disease Mechanisms and Treatments
Keywords
Parkinson's disease, hand tremor, tremor amplitude, tremor frequency, wrist, metacarpophalangeal joint, force sensor, botulinum toxin injection, muscle groups
MeSH terms
Aged, Biomechanical Phenomena, Hand, Humans, Joints, Parkinson Disease, Tremor, Biosensing Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review