The DOI matches its Crossref record.
Role of machine learning in gait analysis: a review
Abstract
Human biomechanics and gait form an integral part of life. The gait analysis involves a large number of interdependent parameters that were difficult to interpret due to a vast amount of data and their inter-relations. To simplify evaluation, the integration of machine learning (ML) with biomechanics is a promising solution. The purpose of this review is to familiarise the readers with key directions of implementation of ML techniques for gait analysis and gait rehabilitation. An extensive literature survey was based on research articles from nine databases published from 1980 to 2019. With over 943 studies identified, finally, 43 studies met the inclusion criteria. The outcome reported illustrates that supervised ML techniques showed accuracies above 90% in the identified gait analysis domain. The statistical results revealed support vector machine (SVM) as the best classifier (mean-score = 0.87 ± 0.07) with remarkable generalisation capability even on small to medium datasets. It has also been analysed that the control strategies for gait rehabilitation are benefitted from reinforcement learning and (deep) neural-networks due to their ability to capture participants' variability. This review paper shows the success of ML techniques in detecting disorders, predicting rehabilitation length, and control of rehabilitation devices which make them suitable for clinical diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hulleck, A. A., Menoth Mohan, D., Abdallah, N., El Rich, M., & Khalaf, K. (2022) · Frontiers in Medical Technology · doi:10.3389/fmedt.2022.901331 · Cited by 281
Wearable sensors and machine learning in post-stroke rehabilitation assessment: A systematic review
Boukhennoufa, I., Zhai, X., Utti, V., Jackson, J., & McDonald-Maier, K. D. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.103197 · Cited by 180
“The reasons for choosing SVM variants is their goodgeneralisation ability for sequential data structures [95] and datasets that are not too large.”
BackgroundDeep Learning Approaches for Enhanced Lower-Limb Exoskeleton Control: A Review
Belal, M., Alsheikh, N., Aljarah, A., & Hussain, I. (2024) · IEEE Access · doi:10.1109/access.2024.3414175 · Cited by 42
Kuch, A., Schweighofer, N., Finley, J. M., McKenzie, A., Wen, Y., & Sánchez, N. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3568325 · Cited by 12
Alam, M. S. B., Lameesa, A., Sharmin, S., Afrin, S., Ahmed, S. F., Nikoo, M. R., & Gandomi, A. H. (2025) · Digital Communications and Networks · doi:10.1016/j.dcan.2025.04.001 · Cited by 9
Metadata
- Authors
- Khera, P., & Kumar, N.
- Venue
- Journal of Medical Engineering & Technology
- Publisher
- Informa UK Limited
- Published
- 2020-10-20
- Volume
- 44
- Issue
- 8
- Pages
- 441-467
- ISSN
- 0309-1902 (ISSN-L)
- 1464-522X
- OpenAlex
- W3092746285
- Cited by
- 187
- References
- 0
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Role of machine learning in gait analysis: a review. https://app.cochat.ai/papers/10.1080/03091902.2020.1822940
- The paper
- Khera, P., & Kumar, N. (2020). Role of machine learning in gait analysis: a review. Journal of Medical Engineering & Technology. https://doi.org/10.1080/03091902.2020.1822940
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.