CoChat

Validation of a 5-minute steady state indirect calorimetry protocol for resting energy expenditure in critically ill patients.

Frankenfield, D C, Sarson, G Y, Blosser, S A, Cooney, R N, Smith, J S · 1996 · Journal of the American College of Nutrition
Cited by 64

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Numerous protocols are used for indirect calorimetry in research and clinical settings. The objective of the current study was to validate in critically ill patients an abbreviated protocol that uses five consecutive stable 1-minute readings of oxygen consumption (VO2), carbon dioxide production (VCO2), and minute ventilation (VE) in a range of +/- 5%, versus a more standard protocol that uses 30 consecutive stable one minute readings of VO2, VCO2, and VE in a range of +/- 10%. METHODS: Indirect calorimetry was performed on resting, mechanically ventilated, critically ill patients. The first 5-minute period in which coefficients of variation for VO2, VCO2, and VE were < or = 5% was compared to the first 30-minute period in which coefficients of variation for these variables were < or = 10%. RESULTS: Thirty-four critically ill patients were studied. Twenty four patients (70%) successfully completed both protocols (Success Group). Eighteen percent of subjects completed neither the abbreviated nor the 30 minute protocol, and 12% completed only one protocol (Fail Group). The Success Group was marked by a higher incidence of sedation and/or medical paralysis. There were no significant differences in VE, VO2, VCO2, respiratory quotient, or energy expenditure between the protocols in the Success Group or the Fail Group. Coefficients of determination (R2) for VO2 and VCO2 between the two methods in the Success Group were 0.99. In the Fail Group, R2 values ranged from 0.75 for VCO2 to 0.91 for VO2. CONCLUSION: In sedated, mechanically ventilated patients, an indirect calorimetry test of five consecutive 1-minute periods with coefficient of variation < or = 5% is equivalent to a longer test consisting of 30 consecutive 1-minute periods with coefficient of variation < or = 10%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/07315724.1996.10718615

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 64

Metadata

Authors
Frankenfield, D. C., Sarson, G. Y., Blosser, S. A., Cooney, R. N., & Smith, J. S.
Venue
Journal of the American College of Nutrition
Published
1996-08
Volume
15
Issue
4
Pages
397-402
ISSN
  • 0731-5724 (ISSN-L)
  • 1541-1087
OpenAlex
W1988393008
Cited by
64
References
1
FWCI
2.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of a 5-minute steady state indirect calorimetry protocol for resting energy expenditure in critically ill patients. https://app.cochat.ai/papers/10.1080/07315724.1996.10718615
The paper
Frankenfield, D. C., Sarson, G. Y., Blosser, S. A., Cooney, R. N., & Smith, J. S. (1996). Validation of a 5-minute steady state indirect calorimetry protocol for resting energy expenditure in critically ill patients. Journal of the American College of Nutrition. https://doi.org/10.1080/07315724.1996.10718615

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.