Evidence-based proposal for the number of ambulatory readings required for assessing blood pressure level in research settings: an analysis of the IDACO database
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Guidelines on the required number of ambulatory blood pressure (ABP) readings focus on individual patients. Clinical researchers often face the dilemma of applying recommendations and discarding potentially valuable information or accepting fewer readings. METHODS: Starting from ABP recordings with ≥30/≥10 awake/asleep readings in 4277 participants enrolled in eight population studies in the International Database on Ambulatory Blood Pressure in Relation to Cardiovascular Outcomes (IDACO), we randomly selected a certain number of readings (from 30 to 1 awake and 10 to 1 asleep readings) at a time over 1000 bootstraps at each step. We evaluated: (i) concordance of the ABP level; (ii) consistency of the cross-classification based on office blood pressure and ABP; and (iii) accuracy in predicting cardiovascular complications. For each criterion, we fitted a regression line joining data points relating outcome to the number of readings covering the ranges of 30-20/10-7 for awake/asleep readings. RESULTS: Reducing readings widened the SD of the systolic/diastolic differences between full (reference) and selected recordings from 1.7/1.2 (30 readings) to 14.3/10.3 mm Hg (single reading) during wakefulness, and from 1.9/1.4 to 10.3/7.7 mm Hg during sleep; lowered the κ statistic from 0.94 to 0.63, and decreased the hazard ratio associated with 10/5 mm Hg increments in systolic/diastolic ABP from 1.21/1.14 to 1.06/1.04 during wakefulness and from 1.26/1.17 to 1.14/1.08 during sleep. The first data points falling off these regression lines during wakefulness/sleep corresponded to 8/3 and 8/4 readings for criteria (i) and (iii) and to 5 awake readings for criterion (ii). CONCLUSIONS: 24-h ambulatory recordings with ≥8/≥4 awake/asleep readings yielded ABP levels similar to recordings including the guideline-recommended ≥20/≥7 readings. These criteria save valuable data in a research setting, but are not applicable to clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationGBD 2010: design, definitions, and metrics
Murray, C. J., Ezzati, M., Flaxman, A. D., Lim, S., Lozano, R., Michaud, C., Naghavi, M., Salomon, J. A., Shibuya, K., Vos, T., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61899-6 · Cited by 1,103 · cited 1×
“4 million deaths every year — more than half of the estimated 17 million deaths per year attributable to total cardiovascular disease [1,2].”
BackgroundThe Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2014)
(2014) · Hypertension Research · doi:10.1038/hr.2014.20 · Cited by 1,049
Asayama, K., Thijs, L., Li, Y., Gu, Y.-M., Hara, A., Liu, Y.-P., Zhang, Z., Wei, F.-F., Lujambio, I., Mena, L. J., et al. (2014) · Hypertension · doi:10.1161/hypertensionaha.114.03614 · Cited by 157
Self-citationMena, L. J., Maestre, G. E., Hansen, T. W., Thijs, L., Liu, Y., Boggia, J., Li, Y., Kikuya, M., Bjorklund-Bodegard, K., Ohkubo, T., et al. (2014) · American Journal of Hypertension · doi:10.1093/ajh/hpt142 · Cited by 72 · cited 1×
“Forty-eight blood pressure readings over 24 hours were adequate to compute ARV without meaningful loss of prognostic information [37].”
MethodSelf-citation
Cited by
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Self-citation2024 ESC Guidelines for the management of elevated blood pressure and hypertension
McEvoy, J. W., McCarthy, C. P., Bruno, R. M., Brouwers, S., Canavan, M. D., Ceconi, C., Christodorescu, R. M., Daskalopoulou, S. S., Ferro, C. J., Gerdts, E., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae178 · Cited by 2,298
Self-citationAssociation of office and ambulatory blood pressure with mortality and cardiovascular outcomes
Yang, W.-Y., Melgarejo, J. D., Thijs, L., Zhang, Z.-Y., Boggia, J., Wei, F.-F., Hansen, T. W., Asayama, K., Ohkubo, T., Jeppesen, J., et al. (2019) · JAMA · doi:10.1001/jama.2019.9811 · Cited by 491
Self-citationKario, K., Hoshide, S., Mizuno, H., Kabutoya, T., Nishizawa, M., Yoshida, T., Abe, H., Katsuya, T., Fujita, Y., Okazaki, O., et al. (2020) · Circulation · doi:10.1161/circulationaha.120.049730 · Cited by 324
Sánchez, R. A., Boggia, J., Peñaherrera, E., Barroso, W. S., Barbosa, E., Villar, R., Cobos, L., Hernández Hernández, R., Lopez, J., Octavio, J. A., et al. (2020) · The Journal of Clinical Hypertension · doi:10.1111/jch.13816 · Cited by 38
Self-citation
Metadata
- Authors
- Yang, W.-Y., Thijs, L., Zhang, Z.-Y., Asayama, K., Boggia, J., Hansen, T. W., Ohkubo, T., Jeppesen, J., Stolarz-Skrzypek, K., Malyutina, S., Casiglia, E., Nikitin, Y., Li, Y., Wang, J.-G., Imai, Y., Kawecka-Jaszcz, K., O’Brien, E., & Staessen, J. A.
- Venue
- Blood Pressure
- Publisher
- Informa UK Limited
- Published
- 2018-06-17
- Volume
- 27
- Issue
- 6
- Pages
- 341-350
- ISSN
- 0803-7051 (ISSN-L)
- 1651-1999
- OpenAlex
- W2808386639
- Cited by
- 47
- References
- 5
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evidence-based proposal for the number of ambulatory readings required for assessing blood pressure level in research settings: an analysis of the IDACO database. https://app.cochat.ai/papers/10.1080/08037051.2018.1476057
- The paper
- Yang, W.-Y., Thijs, L., Zhang, Z.-Y., Asayama, K., Boggia, J., Hansen, T. W., Ohkubo, T., Jeppesen, J., Stolarz-Skrzypek, K., Malyutina, S., Casiglia, E., Nikitin, Y., Li, Y., Wang, J.-G., Imai, Y., Kawecka-Jaszcz, K., O’Brien, E., & Staessen, J. A. (2018). Evidence-based proposal for the number of ambulatory readings required for assessing blood pressure level in research settings: an analysis of the IDACO database. Blood Pressure. https://doi.org/10.1080/08037051.2018.1476057
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.