The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
MEASUREMENT OF TOTAL LUNG DEPOSITION OF INHALED ULTRAFINE PARTICLES IN HEALTHY MEN AND WOMEN
Abstract
Ultrafine particles (< 0.10 microm in diameter) are present in great number in polluted urban air, thus posing a potential health risk. In this study, the total deposition fraction (TDF) of ultrafine aerosols with a narrow size distribution (number median diameter NMD = 0.04-0.1 microm and geometric standard deviation sigma(g) = approximately 1.3) was measured in a group of young healthy adults (11 men and 11 women). TDF was obtained with 6 different breathing patterns: tidal volume (V(t)) of 500 ml at respiratory flow rates (Q) of 150 and 250 ml/s; V(t) = 750 ml at Q of 250 and 375 ml/s; and V(t) = 1 L at Q of 250 and 500 ml/s. Aerosols were monitored continuously by a modified condensation nuclei counter while subjects were inhaling them with prescribed breathing patterns. For a given breathing pattern, TDF increased as particle size decreased, regardless of the breathing pattern used. For example, with V(t) = 500 ml and Q = 250 ml/s, TDF (mean +/- SD) was 0.26 +/-.04, 0.30 +/-. 05, 0.35 +/-.05, and 0.44 +/-.07 for NMD = 0.10, 0.08, 0.06, and 0. 04 microm, respectively. For a given NMD, TDF increased with an increase in V(t) and a decrease in Q. TDF was greater for women than men at NMD = 0.04 microm within all breathing patterns used (p <.05), but the difference was smaller or negligible for larger sized particles. The results suggest that the TDF of ultrafine particles increases with a decrease of particle size and with breathing patterns of longer respiratory time, a pattern that is consistent with diffusion deposition of ultrafine particles. The results also suggest that there is a differential lung dose of ultrafine particles and thus there may be a differential health risk for men versus women.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fuchs, N. A., Daisley, R. E., Fuchs, M., & Davies, C. N. (1964) · Cited by 2,278
Human Respiratory Tract Model for Radiological Protection
Icrp (1994) · Annals of the ICRP · Cited by 1,767
Respiratory effects are associated with the number of ultrafine particles.
Peters, A., Wichmann, H. E., Tuch, T., Heinrich, J., & Heyder, J. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.4.9105082 · Cited by 1,260
Association of Particulate Air Pollution and Acute Mortality: Involvement of Ultrafine Particles?
Oberdörster, G., Celein, R. M., Ferin, J., & Weiss, B. (1995) · Inhalation Toxicology · doi:10.3109/08958379509014275 · Cited by 626
Intercomparison of experimental regional aerosol deposition data
STAHLHOFEN, W., RUDOLF, G., & JAMES, A. C. (1989) · Journal of Aerosol Medicine · doi:10.1089/jam.1989.2.285 · Cited by 423
Breathing patterns. 1. Normal subjects.
Tobin, M. J. (1983) · CHEST Journal · doi:10.1378/chest.84.2.202 · Cited by 267
Regional deposition of inhaled particles in human lungs: comparison between men and women
Kim, C. S., & Hu, S. C. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.6.1834 · Cited by 237
Variability of fine particle deposition in healthy adults: effect of age and gender.
Bennett, W. D., Zeman, K. L., & Kim, C. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.153.5.8630615 · Cited by 166
Airway size is related to sex but not lung size in normal adults
Martin, T. R., Castile, R. G., Fredberg, J. J., Wohl, M. E., & Mead, J. (1987) · Journal of Applied Physiology · doi:10.1152/jappl.1987.63.5.2042 · Cited by 161
ANDERSON, P. J., Wilson, J. D., & Hiller, F. C. (1990) · CHEST Journal · doi:10.1378/chest.97.5.1115 · Cited by 144
Cited by
Nanotoxicology: An Emerging Discipline Evolving from Studies of Ultrafine Particles
Oberdörster, G., Oberdörster, E., & Oberdörster, J. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7339 · Cited by 7,891
Inhaled nanoparticles—A current review
Yang, W., Peters, J. I., & Williams, R. O. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.02.011 · Cited by 666
Airborne Nanostructured Particles and Occupational Health
Maynard, A. D., & Kuempel, E. D. (2005) · Journal of Nanoparticle Research · doi:10.1007/s11051-005-6770-9 · Cited by 559
Nanostructured lipid carriers system: Recent advances in drug delivery
Iqbal, M. A., Md, S., Sahni, J. K., Baboota, S., Dang, S., & Ali, J. (2012) · Journal of Drug Targeting · doi:10.3109/1061186x.2012.716845 · Cited by 436
Elmowafy, M., & Al-Sanea, M. M. (2021) · Saudi Pharmaceutical Journal · doi:10.1016/j.jsps.2021.07.015 · Cited by 382
Metadata
- Authors
- Peter A. Jaques, C. S. K.
- Venue
- Inhalation Toxicology
- Publisher
- Informa UK Limited
- Published
- 2000-01
- Volume
- 12
- Issue
- 8
- Pages
- 715-731
- ISSN
- 0895-8378 (ISSN-L)
- 1091-7691
- OpenAlex
- W2155340607
- Cited by
- 287
- References
- 18
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MEASUREMENT OF TOTAL LUNG DEPOSITION OF INHALED ULTRAFINE PARTICLES IN HEALTHY MEN AND WOMEN. https://app.cochat.ai/papers/10.1080/08958370050085156
- The paper
- Peter A. Jaques, C. S. K. (2000). MEASUREMENT OF TOTAL LUNG DEPOSITION OF INHALED ULTRAFINE PARTICLES IN HEALTHY MEN AND WOMEN. Inhalation Toxicology. https://doi.org/10.1080/08958370050085156
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.