Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 287

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

MEASUREMENT OF TOTAL LUNG DEPOSITION OF INHALED ULTRAFINE PARTICLES IN HEALTHY MEN AND WOMEN

Peter A. Jaques, Chong S. Kim·2000·Inhalation Toxicology

Abstract

Ultrafine particles (< 0.10 microm in diameter) are present in great number in polluted urban air, thus posing a potential health risk. In this study, the total deposition fraction (TDF) of ultrafine aerosols with a narrow size distribution (number median diameter NMD = 0.04-0.1 microm and geometric standard deviation sigma(g) = approximately 1.3) was measured in a group of young healthy adults (11 men and 11 women). TDF was obtained with 6 different breathing patterns: tidal volume (V(t)) of 500 ml at respiratory flow rates (Q) of 150 and 250 ml/s; V(t) = 750 ml at Q of 250 and 375 ml/s; and V(t) = 1 L at Q of 250 and 500 ml/s. Aerosols were monitored continuously by a modified condensation nuclei counter while subjects were inhaling them with prescribed breathing patterns. For a given breathing pattern, TDF increased as particle size decreased, regardless of the breathing pattern used. For example, with V(t) = 500 ml and Q = 250 ml/s, TDF (mean +/- SD) was 0.26 +/-.04, 0.30 +/-. 05, 0.35 +/-.05, and 0.44 +/-.07 for NMD = 0.10, 0.08, 0.06, and 0. 04 microm, respectively. For a given NMD, TDF increased with an increase in V(t) and a decrease in Q. TDF was greater for women than men at NMD = 0.04 microm within all breathing patterns used (p <.05), but the difference was smaller or negligible for larger sized particles. The results suggest that the TDF of ultrafine particles increases with a decrease of particle size and with breathing patterns of longer respiratory time, a pattern that is consistent with diffusion deposition of ultrafine particles. The results also suggest that there is a differential lung dose of ultrafine particles and thus there may be a differential health risk for men versus women.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/08958370050085156

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 287

Metadata

Authors
Peter A. Jaques, C. S. K.
Venue
Inhalation Toxicology
Published
2000-01
Volume
12
Issue
8
Pages
715-731
ISSN
  • 0895-8378 (ISSN-L)
  • 1091-7691
OpenAlex
W2155340607
Cited by
287
References
18
FWCI
2.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MEASUREMENT OF TOTAL LUNG DEPOSITION OF INHALED ULTRAFINE PARTICLES IN HEALTHY MEN AND WOMEN. https://app.cochat.ai/papers/10.1080/08958370050085156
The paper
Peter A. Jaques, C. S. K. (2000). MEASUREMENT OF TOTAL LUNG DEPOSITION OF INHALED ULTRAFINE PARTICLES IN HEALTHY MEN AND WOMEN. Inhalation Toxicology. https://doi.org/10.1080/08958370050085156

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.