The DOI matches its Crossref record.
Platelet-rich plasma preparation using three devices: Implications for platelet activation and platelet growth factor release
Open accessAbstract
BACKGROUND: In this study, three commercial systems for the preparation of platelet-rich plasma (PRP) were compared and platelet growth factors release was measured. METHODS: Ten healthy volunteers donated whole blood that was fractionated by a blood cell separator, and a table-top centrifuge to prepare PRP. Furthermore, an autologous growth factor filter was used to concentrate PRP fractionated by the blood cell separator. PRP was subsequently activated with autologously produced thrombin to degranulate the platelets to measure platelet-derived growth factor-AB (PDGF-AB), transforming growth factor-beta (TGF-beta), insulin-like growth factor-1 (IGF-1), and vascular endothelial growth factor (VEGF). RESULTS: PRP contained significantly higher platelet counts compared with baseline values (p < 0.001). PDGF-AB concentrations were increased more than 18-fold in the platelet gel supernatant when the cell-separator and GPS were used, whereas only a 3-fold increase was seen with the AGF. CONCLUSION: The three PRP devices enable the preparation of PRP for the release of high concentrations of platelet growth factor, but showed different harvesting capacities for the collection of concentrated platelets. The administration of thrombin for PRP activation resulted in the release of high concentrations of PDGF-AB and TGF-beta but only when PRP had not been activated during the preparation process in vitro.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Alsousou, J., Thompson, M., Hulley, P., Noble, A., & Willett, K. (2009) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.91b8.22546 · Cited by 600
Platelet-Rich Plasma Differs According to Preparation Method and Human Variability
Mazzocca, A. D., McCarthy, M. B. R., Chowaniec, D. M., Cote, M. P., Romeo, A. A., Bradley, J. P., Arciero, R. A., & Beitzel, K. (2012) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.k.00430 · Cited by 508
Castillo, T. N., Pouliot, M. A., Kim, H. J., & Dragoo, J. L. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546510387517 · Cited by 498
Dragoo, J. L., Braun, H. J., Durham, J. L., Ridley, B. A., Odegaard, J. I., Luong, R., & Arnoczky, S. P. (2012) · The American Journal of Sports Medicine · doi:10.1177/0363546512442334 · Cited by 299
Bosch, G., van Schie, H. T. M., de Groot, M. W., Cadby, J. A., van de Lest, C. H. A., Barneveld, A., & van Weeren, P. R. (2010) · Journal of Orthopaedic Research · doi:10.1002/jor.20980 · Cited by 267
Metadata
- Authors
- Everts, P. A., Brown Mahoney, C., Hoffmann, J. J., Schönberger, J. P., Box, H. A., van Zundert, A., & Knape, J. T.
- Venue
- Growth Factors
- Publisher
- Informa UK Limited
- Published
- 2006-01
- Volume
- 24
- Issue
- 3
- Pages
- 165-171
- ISSN
- 0897-7194 (ISSN-L)
- 1029-2292
- OpenAlex
- W2032726557
- Cited by
- 218
- References
- 0
- FWCI
- 9.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Platelet-rich plasma preparation using three devices: Implications for platelet activation and platelet growth factor release. https://app.cochat.ai/papers/10.1080/08977190600821327
- The paper
- Everts, P. A., Brown Mahoney, C., Hoffmann, J. J., Schönberger, J. P., Box, H. A., van Zundert, A., & Knape, J. T. (2006). Platelet-rich plasma preparation using three devices: Implications for platelet activation and platelet growth factor release. Growth Factors. https://doi.org/10.1080/08977190600821327
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.