CoChat

Injectable conductive collagen/alginate/polypyrrole hydrogels as a biocompatible system for biomedical applications

Ketabat, Farinaz, Karkhaneh, Akbar, Mehdinavaz Aghdam, Rouhollah, Hossein Ahmadi Tafti, Seyed · 2017 · Journal of Biomaterials Science, Polymer Edition
Cited by 64

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Recently, Injectable Conducting Hydrogel (ICH) systems have gained much attention for tissue engineering and regenerative medicine. These systems can promote the regeneration of tissues responding to electrical responses. In this study, a novel ICH system was introduced. To achieve this system, firstly, a soluble non-toxic polypyrrole (PPy) synthesized by grafting pyrrole on alginate (Alg) backbone (Alg-graft-PPy), and then, ICH systems were prepared by the given ratios of Alg-graft-PPy, Alg, and collagen (Col). Three different amounts of Col (0.5, 1, and 1.5 mg/ml) were added to the system including Alg-graft-PPy: Alg wt. % with the ratios of 20:80 and 30:70. FTIR spectroscopy, electrical conductivity, viscosity, syringeability, gelation time, and MTT assay were performed in order to characterize the produced hydrogels. Due to the rheological behavior of 20:80 (Alg-graft-PPy: Alg wt. %), it was recognized more suitable to inject. Also this system associated with 0.5 mg/ml Col introduced as the best sample with respect to its viscosity and injectability. This ICH system has shown high conductivity in addition to a good level of cell viability and syringeability. With respect to properties of the produced ICH system, it can be applied for bone, nerve, muscle and cardiac cells, which respond to electrical impulses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/09205063.2017.1302314

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 64

Metadata

Authors
Ketabat, F., Karkhaneh, A., Mehdinavaz Aghdam, R., & Hossein Ahmadi Tafti, S.
Venue
Journal of Biomaterials Science, Polymer Edition
Published
2017-03-28
Volume
28
Issue
8
Pages
794-805
ISSN
  • 0920-5063 (ISSN-L)
  • 1568-5624
OpenAlex
W2599797313
Cited by
64
References
1
FWCI
2.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Injectable conductive collagen/alginate/polypyrrole hydrogels as a biocompatible system for biomedical applications. https://app.cochat.ai/papers/10.1080/09205063.2017.1302314
The paper
Ketabat, F., Karkhaneh, A., Mehdinavaz Aghdam, R., & Hossein Ahmadi Tafti, S. (2017). Injectable conductive collagen/alginate/polypyrrole hydrogels as a biocompatible system for biomedical applications. Journal of Biomaterials Science, Polymer Edition. https://doi.org/10.1080/09205063.2017.1302314

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.