CoChat
Cited by 85

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Curcumin‐loaded electrospun polycaprolactone/montmorillonite nanocomposite: wound dressing application with anti‐bacterial and low cell toxicity properties

Sadeghianmaryan, Ali, Yazdanpanah, Zahra, Soltani, Younes Afzal, Sardroud, Hamed Alizadeh, Nasirtabrizi, Mohammad Hossein, Chen, Xiongbiao · 2020 · Journal of Biomaterials Science, Polymer Edition

Abstract

Materials and scaffolds with antimicrobial properties are of great importance in wound dressing and other tissue engineering applications. The objective of the present work was to fabricate scaffolds made from nanocomposites of polycaprolactone (PCL) and quaternary ammonium salt-modified montmorillonite (MMT) by the electrospinning technique, and then characterize their antimicrobial and other properties for wound dressing applications. The effect of MMT on the structure, morphology, and thermal behavior of the electrospun wound dressings was assessed by means of X-ray diffraction (XRD), thermogravimetric analysis (TGA), and scanning electron microscopy (SEM); the swelling capacity, antibacterial activity, and cytotoxicity were also evaluated. The results of XRD and SEM analyses showed MMT was successfully incorporated into the PCL polymeric matrix and its inclusion reduced the size and thickness of the electrospun fibers compared to pure PCL fibers. The TGA results illustrated an increase in the thermal stability of nanocomposites upon incorporation of nanoclay into the PCL matrix. The swelling capacity of the wound dressings was reduced by increasing the amount of MMT in the PCL matrix due to the increased hydrophobicity of the original MMT resulting from its modification with quaternary ammonium salt. The in vitro curcumin (Cur) release profile revealed an initial burst release followed by a sustained release, with the burst release level reduced by the introduction of MMT into the polymeric matrix. Increasing the nanoclay content further reduced the curcumin release, with the PCL/20% MMT/Cur dressings having the lowest curcumin release of all those tested. The beneficial effect of MMT on the antibacterial behavior of electrospun wound dressings based on PCL/MMT nanocomposites was confirmed, with the introduction of both MMT and curcumin into the PCL matrix resulting in lower bacterial viability. PCL/10% MMT/Cur demonstrated higher antimicrobial activity and the greatest bacterial colony reduction compared to both pure PCL and PCL/10% MMT. The cytotoxicity evaluation indicated low toxicity and confirmed the potential of PCL/MMT nanocomposite scaffolds for wound dressing applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/09205063.2019.1680928

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 35

  1. 10.1016/j.ijbiomac.2017.11.035 · doi:10.1016/j.ijbiomac.2017.11.035
  2. 10.1016/j.ijbiomac.2019.08.153 · DOI · Paper page
  3. 10.1016/j.carbpol.2015.08.030 · DOI
  4. 10.1016/j.carbpol.2011.01.005 · DOI · Paper page
  5. 10.4236/jbnb.2011.24051 · DOI · Paper page
  6. 10.1021/mp300075u · DOI · Paper page
  7. 10.1021/bm3017324 · DOI · Paper page
  8. 10.1007/s12247-016-9253-x · DOI
  9. 10.1016/j.colsurfa.2018.04.018 · DOI
  10. 10.1039/C8RA01898G · DOI
  11. 10.3390/jfb7030018 · DOI
  12. 10.1039/C5RA24251G · doi:10.1039/c5ra24251g
  13. 10.1021/bm301537g · DOI
  14. 10.1016/j.colsurfb.2012.10.068 · DOI · Paper page
  15. 10.1007/s10965-013-0189-2 · DOI
  16. 10.1016/j.jiec.2014.07.005 · DOI
  17. 10.1016/j.ijpharm.2013.08.043 · DOI · Paper page
  18. Datta M., 2013, Appl Clay Sci, 80, 85
  19. 10.1016/j.clay.2014.06.006 · DOI
  20. 10.1016/j.jddst.2017.03.023 · DOI · Paper page
  21. 10.1039/C7TB01964E · DOI
  22. 10.3390/jfb10020023 · doi:10.3390/jfb10020023
  23. 10.1016/j.actbio.2007.12.005 · DOI
  24. 10.1177/0021998312439221 · doi:10.1177/0021998312439221
  25. 10.1007/s12221-013-0957-y · doi:10.1007/s12221-013-0957-y
  26. 10.1177/0095244313489906 · DOI
  27. Mohanty DP, 2012, Int J Pharm Res Allied Sci, 1, 52
  28. 10.1007/s40204-017-0062-1 · DOI
  29. 10.4236/jbnb.2011.21008 · DOI · Paper page
  30. 10.1002/app.12624 · DOI · Paper page
  31. 10.4103/2230-973X.176468 · DOI · Paper page
  32. 10.7324/JAPS.2016.60710 · DOI
  33. 10.1166/jnn.2008.248 · doi:10.1166/jnn.2008.248
  34. 10.1177/155892501300800416 · doi:10.1177/155892501300800416
  35. 10.1016/j.nano.2008.09.004 · DOI · Paper page

Cited by

See all 85

Metadata

Authors
Sadeghianmaryan, A., Yazdanpanah, Z., Soltani, Y. A., Sardroud, H. A., Nasirtabrizi, M. H., & Chen, X.
Venue
Journal of Biomaterials Science, Polymer Edition
Published
2019-10-30
Volume
31
Issue
2
Pages
169-187
ISSN
  • 0920-5063
  • 1568-5624
Cited by
85
References
1
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.