The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Advances in InGaAsP-based avalanche diode single photon detectors
Abstract
In this Topical Review, we survey the state-of-the-art of single photon detectors based on avalanche diodes fabricated in the InGaAsP materials system for photon counting at near infrared wavelengths in the range from 0.9–1.6 µm. The fundamental trade-off between photon detection efficiency and dark count rate can now be managed with performance that adequately serves many applications, with low dark count rates of ∼1 kHz having been demonstrated at photon detection efficiencies of 20% for 25 µm diameter fiber-coupled devices with thermoelectric cooling. Timing jitter of less than 50 ps has been achieved, although device uniformity is shown to be essential in obtaining good jitter performance. Progress is also reported towards resolving the limitations imposed on photon counting rate by afterpulsing, with at least 50 MHz repetition frequencies demonstrated for 1 ns gated operation with afterpulsing limited to the range of 1–5%. We also present a discussion of future trends and challenges related to these devices organized according to the hierarchy of materials properties, device design concepts, signal processing and electronic circuitry, and multiplexing concepts. Whereas the materials properties of these devices may pose significant challenges for the foreseeable future, there has been considerable progress in device concepts and circuit solutions towards the present imperatives for higher counting rates and simpler device operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gisin, N., Ribordy, G., Tittel, W., & Zbinden, H. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.145 · Cited by 8,515
A scheme for efficient quantum computation with linear optics
Knill, E., Laflamme, R., & Milburn, G. J. (2001) · Nature · doi:10.1038/35051009 · Cited by 5,880
Experimental violation of Bell’s inequality based on phase and momentum
Rarity, J. G., & Tapster, P. R. (1990) · Physical Review Letters · doi:10.1103/physrevlett.64.2495 · Cited by 612
Cited by
Superconducting nanowire single-photon detectors: physics and applications
Natarajan, C. M., Tanner, M. G., & Hadfield, R. H. (2012) · Superconductor Science and Technology · doi:10.1088/0953-2048/25/6/063001 · Cited by 970
Pernice, W. H. P., Schuck, C., Minaeva, O., Li, M., Goltsman, G. N., Sergienko, A. V., & Tang, H. X. (2012) · Nature Communications · doi:10.1038/ncomms2307 · Cited by 477
Advances in InGaAs/InP single-photon detector systems for quantum communication
Zhang, J., Itzler, M. A., Zbinden, H., & Pan, J.-W. (2015) · Light: Science & Applications · doi:10.1038/lsa.2015.59 · Cited by 436
Self-citationWasisto, H. S., Prades, J. D., Gülink, J., & Waag, A. (2019) · Applied Physics Reviews · doi:10.1063/1.5096322 · Cited by 309
Kahl, O., Ferrari, S., Kovalyuk, V., Goltsman, G. N., Korneev, A., & Pernice, W. H. P. (2015) · Scientific Reports · doi:10.1038/srep10941 · Cited by 102
Metadata
- Authors
- Itzler, M. A., Jiang, X., Entwistle, M., Slomkowski, K., Tosi, A., Acerbi, F., Zappa, F., & Cova, S.
- Venue
- Journal of Modern Optics
- Publisher
- Informa UK Limited
- Published
- 2011-02-10
- Volume
- 58
- Issue
- 3-4
- Pages
- 174-200
- ISSN
- 0950-0340 (ISSN-L)
- 1362-3044
- OpenAlex
- W1969242926
- Cited by
- 213
- References
- 3
- FWCI
- 17.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advances in InGaAsP-based avalanche diode single photon detectors. https://app.cochat.ai/papers/10.1080/09500340.2010.547262
- The paper
- Itzler, M. A., Jiang, X., Entwistle, M., Slomkowski, K., Tosi, A., Acerbi, F., Zappa, F., & Cova, S. (2011). Advances in InGaAsP-based avalanche diode single photon detectors. Journal of Modern Optics. https://doi.org/10.1080/09500340.2010.547262
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.