Photon-number-resolution with sub-30-ps timing using multi-element superconducting nanowire single photon detectors
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A photon-number-resolving detector based on a four-element superconducting nanowire single photon detector is demonstrated to have sub-30-ps resolution in measuring the arrival time of individual photons. This detector can be used to characterise the photon statistics of non-pulsed light sources and to mitigate dead-time effects in high-speed photon counting applications. Furthermore, a 25% system detection efficiency at 1550 nm was demonstrated, making the detector useful for both low-flux source characterization and high-speed photon counting and quantum communication applications. The design, fabrication, and testing of this detector are described, and a comparison between the measured and the theoretical performance is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A scheme for efficient quantum computation with linear optics
Knill, E., Laflamme, R., & Milburn, G. J. (2001) · Nature · doi:10.1038/35051009 · Cited by 5,880
Cabrera, B., Clarke, R. M., Colling, P., Miller, A. J., Nam, S., & Romani, R. W. (1998) · Applied Physics Letters · doi:10.1063/1.121984 · Cited by 352
Cited by
Single-photon detectors for optical quantum information applications
Hadfield, R. H. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.230 · Cited by 1,726
Invited Review Article: Single-photon sources and detectors
Eisaman, M. D., Fan, J., Migdall, A., & Polyakov, S. V. (2011) · Review of Scientific Instruments · doi:10.1063/1.3610677 · Cited by 1,358
Superconducting nanowire single-photon detectors: physics and applications
Natarajan, C. M., Tanner, M. G., & Hadfield, R. H. (2012) · Superconductor Science and Technology · doi:10.1088/0953-2048/25/6/063001 · Cited by 970
Esmaeil Zadeh, I., Chang, J., Los, J. W. N., Gyger, S., Elshaari, A. W., Steinhauer, S., Dorenbos, S. N., & Zwiller, V. (2021) · Applied Physics Letters · doi:10.1063/5.0045990 · Cited by 331
On-chip detection of non-classical light by scalable integration of single-photon detectors
Najafi, F., Mower, J., Harris, N. C., Bellei, F., Dane, A., Lee, C., Hu, X., Kharel, P., Marsili, F., Assefa, S., et al. (2015) · Nature Communications · doi:10.1038/ncomms6873 · Cited by 330
Self-citation
Metadata
- Authors
- Dauler, E. A., Kerman, A. J., Robinson, B. S., Yang, J. K. W., Voronov, B., Goltsman, G., Hamilton, S. A., & Berggren, K. K.
- Venue
- Journal of Modern Optics
- Publisher
- Informa UK Limited
- Published
- 2009-01-20
- Volume
- 56
- Issue
- 2-3
- Pages
- 364-373
- ISSN
- 0950-0340 (ISSN-L)
- 1362-3044
- OpenAlex
- W2059442452
- Cited by
- 124
- References
- 2
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photon-number-resolution with sub-30-ps timing using multi-element superconducting nanowire single photon detectors. https://app.cochat.ai/papers/10.1080/09500340802411989
- The paper
- Dauler, E. A., Kerman, A. J., Robinson, B. S., Yang, J. K. W., Voronov, B., Goltsman, G., Hamilton, S. A., & Berggren, K. K. (2009). Photon-number-resolution with sub-30-ps timing using multi-element superconducting nanowire single photon detectors. Journal of Modern Optics. https://doi.org/10.1080/09500340802411989
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.