Does Incomplete Repair Explain the Apparent Failure of the Basic LQ Model to Predict Spinal Cord and Kidney Responses to Low Doses Per Fraction?
The DOI matches its Crossref record.
Abstract
Recent evidence indicates that isoeffect doses for spinal cord and kidney may be overestimated for fraction sizes as small as 1 or 2 Gy when calculated from a linear-quadratic (LQ) model fitted to data obtained for fraction sizes larger than 2 Gy. Reasons for this are unknown, but possible interpretations include exhaustion of repair capacity and incomplete repair in experiments designed to study the response to these small doses. The latter interpretation is motivated by the relatively short intervals between multiple daily doses given to the spinal cord (4 h) and kidney (5 h) when fraction sizes were small. The possibility that overestimation of isoeffect dose could be explained by incomplete repair during short intervals between doses was assessed by fitting experimental data to the incomplete-repair model. For the spinal cord the data could be interpreted by assuming that a repair process with a half-time of 1.7 h was incomplete; this half-time is negligibly different from the estimate obtained from repair-kinetics experiments with larger doses per fraction. The deviation from the (complete-repair) LQ model could be interpreted for the kidney in terms of a half-time of repair of 2.8 h (a negligibly different fit was obtained with the value 1.5 h). The clinical implication could be that multiple-fractions-per-day treatment would benefit from use of the longest feasible interfraction interval when late reactions are dose limiting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The linear-quadratic formula and progress in fractionated radiotherapy
Fowler, J. F. (1989) · The British Journal of Radiology · doi:10.1259/0007-1285-62-740-679 · Cited by 2,252
Stewart, F. A., Akleyev, A. V., Hauer-Jensen, M., Hendry, J. H., Kleiman, N. J., MacVittie, T. J., Aleman, B. M., Edgar, A. B., Mabuchi, K., Muirhead, C. R., et al. (2012) · Annals of the ICRP · doi:10.1016/j.icrp.2012.02.001 · Cited by 1,604
Self-citationRadiation response of the central nervous system
Schultheiss, T. E., Kun, L. E., Ang, K. K., & Stephens, L. C. (1995) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(94)00655-5 · Cited by 653
Self-citationAn Overview of Hypofractionation and Introduction to This Issue of Seminars in Radiation Oncology
Timmerman, R. D. (2008) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2008.04.001 · Cited by 478
Bodei, L., Cremonesi, M., Ferrari, M., Pacifici, M., Grana, C. M., Bartolomei, M., Baio, S. M., Sansovini, M., & Paganelli, G. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0778-1 · Cited by 428
Metadata
- Authors
- Thames, H. D., Ang, K. K., Stewart, F. A., & van der Schueren, E.
- Venue
- International Journal of Radiation Biology
- Publisher
- Informa UK Limited
- Published
- 1988-01
- Volume
- 54
- Issue
- 1
- Pages
- 13-19
- ISSN
- 0955-3002 (ISSN-L)
- 1362-3095
- OpenAlex
- W1983654749
- Cited by
- 91
- References
- 0
- FWCI
- 8.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Does Incomplete Repair Explain the Apparent Failure of the Basic LQ Model to Predict Spinal Cord and Kidney Responses to Low Doses Per Fraction? https://app.cochat.ai/papers/10.1080/09553008814551461
- The paper
- Thames, H. D., Ang, K. K., Stewart, F. A., & van der Schueren, E. (1988). Does Incomplete Repair Explain the Apparent Failure of the Basic LQ Model to Predict Spinal Cord and Kidney Responses to Low Doses Per Fraction? International Journal of Radiation Biology. https://doi.org/10.1080/09553008814551461
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.