Easy biodosimetry for high-dose radiation exposures using drug-induced, prematurely condensed chromosomes
The DOI matches its Crossref record.
Abstract
PURPOSE: To propose a practical method of biodosimetry for high-dose estimation. MATERIALS AND METHODS: Okadaic acid in the range 100 nM to 500 nM was given for 1-6 h to cultured lymphocytes that had been exposed in the range of 0 Gy to 40 Gy. The frequency of the cells with prematurely condensed chromosomes (PCC) was compared with that of metaphases accumulated by 0.05 microg/ml colcemid. The dose-response relationship of the yield of prematurely condensed ring chromosomes (PCC rings) in the irradiated lymphocytes was examined. RESULTS: The 0.05 microg/ml colcemid collected few metaphases when lymphocytes were irradiated to over 10 Gy. However, 500 nM okadaic acid produced a substantial number of analysable PCC in lymphocytes that had been exposed in the range of 0 Gy to 40 Gy. After 1 h of treatment, the 500 nM okadaic acid gave the most suitable chromosome morphology for the analysis. PCC rings were narrow, which facilitated their detection in Giemsa-stained preparations. The yield of PCC rings increased dose-dependently up to 20 Gy. CONCLUSION: PCC rings are a more suitable indicator than dicentrics at high doses over 10 Gy. This technique requires no particular equipment or exceptional skill. After a serious radiation accident, it can be easily performed in a short time in most medical facilities to obtain dose information to assist physicians.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Waselenko, J. K., MacVittie, T. J., Blakely, W. F., Pesik, N., Wiley, A. L., Dickerson, W. E., Tsu, H., Confer, D. L., Coleman, C. N., Seed, T., et al. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-12-200406150-00015 · Cited by 766
Lee, R., Nasonova, E., Hartel, C., Durante, M., & Ritter, S. (2011) · Radiation and Environmental Biophysics · doi:10.1007/s00411-011-0360-2 · Cited by 25
Gudowska-Nowak, E., Kleczkowski, A., Nasonova, E., Scholz, M., & Ritter, S. (2005) · International Journal of Radiation Biology · doi:10.1080/09553000400027902 · Cited by 20
Metadata
- Authors
- KANDA, R.
- Venue
- International Journal of Radiation Biology
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 75
- Issue
- 4
- Pages
- 441-446
- ISSN
- 0955-3002 (ISSN-L)
- 1362-3095
- OpenAlex
- W2137511483
- Cited by
- 99
- References
- 0
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Easy biodosimetry for high-dose radiation exposures using drug-induced, prematurely condensed chromosomes. https://app.cochat.ai/papers/10.1080/095530099140366
- The paper
- KANDA, R. (1999). Easy biodosimetry for high-dose radiation exposures using drug-induced, prematurely condensed chromosomes. International Journal of Radiation Biology. https://doi.org/10.1080/095530099140366
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.