Comparative Study of the Microbial Quality of Greywater treated by Three On-Site Treatment Systems
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper analyses the performance of a pilot scale treatment plant, treating light domestic greywater. The treatment included three parallel treatment units: stand-alone sand filtration (SFEB), RBC followed by sand filtration (SFRBC), and an MBR equipped with UF membranes (MBR). The performance of the SFEB unit was rather poor. The RBC and MBR units produced effluent of excellent quality, with COD of 42 and 40 mg l(-1), BOD of 1.8 and 1.1 mg l(-1), and turbidity of 0.6 and 0.2 NTU respectively. The SFEB failed to remove heterotrophic microorganisms (HPC), while the SFRBC and the MBR exhibited 2.1 and 3.6 logs removal, leading to effluent concentrations of 1.1 x 10(3) and 8.8 x 10(3) cfu ml(-1) respectively. Faecal coliforms (FC) counts were 3.4 x 10(5) 1.4 x 10(5) 1.1 x 10(3) and 3.5 x 10(2) cfu 100 ml(-1) in raw greywater, and in the SFEB, SFRBC and MBR effluents respectively. Further, in 60% of the samples no FC were detected in the MBR effluent. In order to simulate residence times in full scale systems, effluents were disinfected and stored for 0.5 h, 3 h, 6 h (normal operation), and one week (extreme event). The average chlorine demand was 8.1, 3.8 and 2.9 mg l(-1) for SFEB, SFRBC and MBR effluents respectively. Low residual chlorine (0.15-0.22 mg l(-1)) remained in all effluents even after a week-long storage. Disinfection reduced HPC by 5, 2 and 2 orders of magnitude in the SFEB, SFRBC and MBR effluents respectively, with no regrowth in short contact times (up to 6 hours). Some regrowth was observed after a week-long storage leading to 10(6), 10(4) and 10(3) cfu ml(-1) (SFEB SFRBC and MBR respectively). Disinfection reduced FC counts in all three types of effluent to 0 cfu 100 ml(-1), whilst no FC regrowth was observed after week-long storage. The results show that both RBC and MBR treatment units are viable options for on-site greywater reuse. The disinfection experiments strongly indicate that the health risk associated with the reuse of these effluents is minimal even after long period of storage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eriksson, E., Auffarth, K., Eilersen, A.-M., Henze, M., & Ledin, A. (2003) · Water SA · doi:10.4314/wsa.v29i2.4848 · Cited by 291
Cited by
Greywater Characteristics, Treatment Systems, Reuse Strategies and User Perception—a Review
Oteng-Peprah, M., Acheampong, M. A., & deVries, N. K. (2018) · Water, Air, & Soil Pollution · doi:10.1007/s11270-018-3909-8 · Cited by 367
A study of the microbial quality of grey water and an evaluation of treatment technologies for reuse
Winward, G. P., Avery, L. M., Frazer-Williams, R., Pidou, M., Jeffrey, P., Stephenson, T., & Jefferson, B. (2008) · Ecological Engineering · doi:10.1016/j.ecoleng.2007.11.001 · Cited by 228
Constructed wetlands for greywater recycle and reuse: A review
Arden, S., & Ma, X. (2018) · Science of The Total Environment · doi:10.1016/j.scitotenv.2018.02.218 · Cited by 220
A review on greywater reuse: quality, risks, barriers and global scenarios
Vuppaladadiyam, A. K., Merayo, N., Prinsen, P., Luque, R., Blanco, A., & Zhao, M. (2019) · Reviews in Environmental Science and Bio/Technology · doi:10.1007/s11157-018-9487-9 · Cited by 180
Gilboa, Y., & Friedler, E. (2008) · Water Research · doi:10.1016/j.watres.2007.09.027 · Cited by 130
Self-citation
Metadata
- Authors
- Friedler, E., Kovalio, R., & Ben-Zvi, A.
- Venue
- Environmental Technology
- Publisher
- Informa UK Limited
- Published
- 2006-06
- Volume
- 27
- Issue
- 6
- Pages
- 653-663
- ISSN
- 0959-3330 (ISSN-L)
- 1479-487X
- OpenAlex
- W2010100573
- Cited by
- 96
- References
- 1
- FWCI
- 11.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.