The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Do ‘green’ buildings have better indoor environments? New evidence
Abstract
A post-occupancy evaluation (POE) of 12 green and 12 conventional office buildings across Canada and the northern United States was conducted. Occupants (N = 2545) completed an online questionnaire related to environmental satisfaction, job satisfaction and organizational commitment, health and well-being, environmental attitudes, and commuting. In each building on-site physical measurements at a sample of workstations (N= 974) were taken, including: thermal conditions, air quality, acoustics, lighting, workstation size, ceiling height, window access and shading, and surface finishes. Green buildings exhibited superior performance compared with similar conventional buildings. Better outcomes included: environmental satisfaction, satisfaction with thermal conditions, satisfaction with the view to the outside, aesthetic appearance, less disturbance from heating, ventilation and air-conditioning (HVAC) noise, workplace image, night-time sleep quality, mood, physical symptoms, and reduced number of airborne particulates. A variety of physical features led to improved occupant outcomes across all buildings, including: conditions associated with speech privacy, lower background noise levels, higher light levels, greater access to windows, conditions associated with thermal comfort, and fewer airborne particulates. Green building rating systems might benefit from further attention in several areas, including: credits related to acoustic performance, a greater focus on reducing airborne particulates, enhanced support for the interdisciplinary design process and development of POE protocols. Il a été mené une évaluation après occupation (POE) de 12 immeubles de bureaux verts et 12 immeubles de bureaux classiques répartis à travers le Canada et le nord des Etats-Unis. Les occupants (N = 2545) ont rempli un questionnaire en ligne portant sur la satisfaction environnementale, la satisfaction au travail et l'implication organisationnelle, la santé et le bien-être, les attitudes environnementales, et les trajets réguliers. Dans chaque immeuble, des mesures physiques in situ sur un échantillon de postes de travail (N = 974) ont été effectuées, comprenant : les conditions thermiques, la qualité de l'air, l'acoustique, l'éclairage, la taille des postes de travail, la hauteur de plafond, l'accès aux fenêtres et leur occultation, et les finitions de surface. Les bâtiments verts ont affiché des performances supérieures par rapport aux bâtiments classiques similaires. De meilleurs résultats ont été obtenus concernant la satisfaction environnementale, la satisfaction à l'égard des conditions thermiques, la satisfaction à l'égard de la vue sur l'extérieur, l'aspect esthétique, la diminution des perturbations liées aux bruits provenant du chauffage, de la ventilation et de la climatisation (CVC), l'image du lieu de travail, la qualité du sommeil nocturne, l'humeur, les symptômes physiques, et la réduction du nombre de particules en suspension dans l'air. Différentes caractéristiques physiques ont conduit à une amélioration des résultats pour les occupants dans tous les immeubles, concernant notamment les conditions liées à la confidentialité des conversations, les niveaux inférieurs de bruit de fond, les niveaux de luminosité plus élevés, l'accès accru aux fenêtres, les conditions associées au confort thermique, et le nombre moindre de particules en suspension dans l'air. Les systèmes de notation des bâtiments verts pourraient bénéficier d'une plus grande attention apportée à plusieurs domaines, s'agissant en particulier des crédits relatifs aux performances acoustiques, d'un accent accru sur la réduction des particules en suspension dans l'air, d'un soutien renforcé en faveur du processus de conception interdisciplinaire et du développement de protocoles POE. Mots clés: performances des bâtiments, bilan environnemental, bâtiments verts, environnement intérieur, Leadership in Energy and Environmental Design (LEED), satisfaction des occupants, évaluation après occupation
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dunlap, R. E., Van Liere, K. D., Mertig, A. G., & Jones, R. E. (2000) · Journal of Social Issues · doi:10.1111/0022-4537.00176 · Cited by 5,678
New well-being measures: Short scales to assess flourishing and positive and negative feelings
Diener, E., Wirtz, D., Tov, W., Kim-Prieto, C., Choi, D.-W., Oishi, S., & Biswas-Diener, R. (2010) · Social Indicators Research · doi:10.1007/s11205-009-9493-y · Cited by 4,980 · cited 1×
“A scale by Diener et al. (2010) gauged mood (affect).”
Cited by
A review of human thermal comfort in the built environment
Rupp, R. F., Vásquez, N. G., & Lamberts, R. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.047 · Cited by 907
Direct human health risks of increased atmospheric carbon dioxide
Jacobson, T. A., Kler, J. S., Hernke, M. T., Braun, R. K., Meyer, K. C., & Funk, W. E. (2019) · Nature Sustainability · doi:10.1038/s41893-019-0323-1 · Cited by 609
Tham, K. W. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.071 · Cited by 399
The impact of thermal environment on occupant IEQ perception and productivity
Geng, Y., Ji, W., Lin, B., & Zhu, Y. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.05.022 · Cited by 388
Wuni, I. Y., Shen, G. Q. P., & Osei-Kyei, R. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.02.010 · Cited by 370
Metadata
- Authors
- Newsham, G. R., Birt, B. J., Arsenault, C., Thompson, A. J. L., Veitch, J. A., Mancini, S., Galasiu, A. D., Gover, B. N., Macdonald, I. A., & Burns, G. J.
- Venue
- Building Research & Information
- Publisher
- Informa UK Limited
- Published
- 2013-08
- Volume
- 41
- Issue
- 4
- Pages
- 415-434
- ISSN
- 0961-3218 (ISSN-L)
- 1466-4321
- OpenAlex
- W1971415684
- Cited by
- 191
- References
- 2
- FWCI
- 16.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Do ‘green’ buildings have better indoor environments? New evidence. https://app.cochat.ai/papers/10.1080/09613218.2013.789951
- The paper
- Newsham, G. R., Birt, B. J., Arsenault, C., Thompson, A. J. L., Veitch, J. A., Mancini, S., Galasiu, A. D., Gover, B. N., Macdonald, I. A., & Burns, G. J. (2013). Do ‘green’ buildings have better indoor environments? New evidence. Building Research & Information. https://doi.org/10.1080/09613218.2013.789951
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.