Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 179

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

The Modified – Modified Schober Test for range of motion assessment of lumbar flexion in patients with low back pain: A study of criterion validity, intra- and inter-rater reliability and minimum metrically detectable change

Tousignant, M, Poulin, L, Marchand, S, Viau, A, Place, C·2005·Disability and Rehabilitation

Abstract

PURPOSE: The objective was to estimate the psychometric properties of the Modified-Modified Schober Test (MMST). DESIGN: This study compared range of motion measurements of lumbar flexion in low back pain (LBP) patients using the MMST with measurements calculated on X-rays as the gold standard, and compared the measurements taken by two independent examiners. METHOD: This study was conducted at the main hospital in the Outaouais area, Quebéc, Canada. Thirty-one subjects with LBP from private and public clinics participated in the study. After a warm-up session, measurements with the MMST were taken in neutral position and an X-ray technician took an exposure in the same position. RESULTS: Pearson's correlation test (r) between measurements made with the MMST and the gold standard, intra-class correlation coefficient (ICC), minimum metrically detectable change (MMDC) and confidence interval (CI) were used to analyze the data. The MMST demonstrated moderate validity (r=0.67; 95%CI 0.44-0.84), excellent reliability (intra: ICC=0.95; 95%CI 0.89-0.97; inter: ICC=0.91; 95%CI 0.83-0.96) and a MMDC of 1 cm. CONCLUSIONS: In our sample of LBP patients, the MMST showed moderate validity but excellent reliability and MMDC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/09638280400018411

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Metadata

Authors
Tousignant, M., Poulin, L., Marchand, S., Viau, A., & Place, C.
Venue
Disability and Rehabilitation
Published
2005-05-20
Volume
27
Issue
10
Pages
553-559
ISSN
  • 0963-8288 (ISSN-L)
  • 1464-5165
OpenAlex
W2048420077
Cited by
179
References
2
FWCI
0.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Modified – Modified Schober Test for range of motion assessment of lumbar flexion in patients with low back pain: A study of criterion validity, intra- and inter-rater reliability and minimum metrically detectable change. https://app.cochat.ai/papers/10.1080/09638280400018411
The paper
Tousignant, M., Poulin, L., Marchand, S., Viau, A., & Place, C. (2005). The Modified – Modified Schober Test for range of motion assessment of lumbar flexion in patients with low back pain: A study of criterion validity, intra- and inter-rater reliability and minimum metrically detectable change. Disability and Rehabilitation. https://doi.org/10.1080/09638280400018411

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.