The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
The Modified – Modified Schober Test for range of motion assessment of lumbar flexion in patients with low back pain: A study of criterion validity, intra- and inter-rater reliability and minimum metrically detectable change
Abstract
PURPOSE: The objective was to estimate the psychometric properties of the Modified-Modified Schober Test (MMST). DESIGN: This study compared range of motion measurements of lumbar flexion in low back pain (LBP) patients using the MMST with measurements calculated on X-rays as the gold standard, and compared the measurements taken by two independent examiners. METHOD: This study was conducted at the main hospital in the Outaouais area, Quebéc, Canada. Thirty-one subjects with LBP from private and public clinics participated in the study. After a warm-up session, measurements with the MMST were taken in neutral position and an X-ray technician took an exposure in the same position. RESULTS: Pearson's correlation test (r) between measurements made with the MMST and the gold standard, intra-class correlation coefficient (ICC), minimum metrically detectable change (MMDC) and confidence interval (CI) were used to analyze the data. The MMST demonstrated moderate validity (r=0.67; 95%CI 0.44-0.84), excellent reliability (intra: ICC=0.95; 95%CI 0.89-0.97; inter: ICC=0.91; 95%CI 0.83-0.96) and a MMDC of 1 cm. CONCLUSIONS: In our sample of LBP patients, the MMST showed moderate validity but excellent reliability and MMDC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Hahne, A. J., Keating, J. L., & Wilson, S. C. (2004) · Australian Journal of Physiotherapy · doi:10.1016/s0004-9514(14)60244-0 · Cited by 71
Metadata
- Authors
- Tousignant, M., Poulin, L., Marchand, S., Viau, A., & Place, C.
- Venue
- Disability and Rehabilitation
- Publisher
- Informa UK Limited
- Published
- 2005-05-20
- Volume
- 27
- Issue
- 10
- Pages
- 553-559
- ISSN
- 0963-8288 (ISSN-L)
- 1464-5165
- OpenAlex
- W2048420077
- Cited by
- 179
- References
- 2
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Modified – Modified Schober Test for range of motion assessment of lumbar flexion in patients with low back pain: A study of criterion validity, intra- and inter-rater reliability and minimum metrically detectable change. https://app.cochat.ai/papers/10.1080/09638280400018411
- The paper
- Tousignant, M., Poulin, L., Marchand, S., Viau, A., & Place, C. (2005). The Modified – Modified Schober Test for range of motion assessment of lumbar flexion in patients with low back pain: A study of criterion validity, intra- and inter-rater reliability and minimum metrically detectable change. Disability and Rehabilitation. https://doi.org/10.1080/09638280400018411
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.