The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A computationally efficient optimisation-based method for parameter identification of kinematically determinate and over-determinate biomechanical systems
Abstract
This paper introduces a general optimisation-based method for identification of biomechanically relevant parameters in kinematically determinate and over-determinate systems from a given motion. The method is designed to find a set of parameters that is constant over the time frame of interest as well as the time-varying system coordinates, and it is particularly relevant for biomechanical motion analysis where the system parameters can be difficult to accurately determine by direct measurements. Although the parameter identification problem results in a large-scale optimisation problem, we show that, due to a special structure in the linearised Karush–Kuhn–Tucker optimality conditions, the solution can be found very efficiently. The method is applied to a set of test problems relevant for gait analysis. These involve determining the local coordinates of markers placed on the model, segment lengths and joint axes of rotation from both gait and range of motion experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of a functional method for the estimation of hip joint centre location
Leardini, A., Cappozzo, A., Catani, F., Toksvig-Larsen, S., Petitto, A., Sforza, V., Cassanelli, G., & Giannini, S. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00148-1 · Cited by 415
Cited by
Marra, M. A., Vanheule, V., Fluit, R., Koopman, B. H. F. J. M., Rasmussen, J., Verdonschot, N., & Andersen, M. S. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029258 · Cited by 278
Self-citationWerling, K., Bianco, N. A., Raitor, M., Stingel, J., Hicks, J. L., Collins, S. H., Delp, S. L., & Liu, C. K. (2023) · PLOS ONE · doi:10.1371/journal.pone.0295152 · Cited by 65
Wibawa, A. D., Verdonschot, N., Halbertsma, J. P. K., Burgerhof, J. G. M., Diercks, R. L., & Verkerke, G. J. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.09.041 · Cited by 25
Soodmand, I., Herrmann, S., Kleist, E., Volpert, A., Wackerle, H., Augat, P., Bader, R., Woernle, C., & Kebbach, M. (2025) · Scientific Reports · doi:10.1038/s41598-025-94394-3 · Cited by 5
Metadata
- Authors
- Andersen, M. S., Damsgaard, M., MacWilliams, B., & Rasmussen, J.
- Venue
- Computer Methods in Biomechanics and Biomedical Engineering
- Publisher
- Informa UK Limited
- Published
- 2010-04
- Volume
- 13
- Issue
- 2
- Pages
- 171-183
- ISSN
- 1025-5842 (ISSN-L)
- 1476-8259
- OpenAlex
- W2066065077
- Cited by
- 188
- References
- 1
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A computationally efficient optimisation-based method for parameter identification of kinematically determinate and over-determinate biomechanical systems. https://app.cochat.ai/papers/10.1080/10255840903067080
- The paper
- Andersen, M. S., Damsgaard, M., MacWilliams, B., & Rasmussen, J. (2010). A computationally efficient optimisation-based method for parameter identification of kinematically determinate and over-determinate biomechanical systems. Computer Methods in Biomechanics and Biomedical Engineering. https://doi.org/10.1080/10255840903067080
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.