The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays
Abstract
In clinical routine, lower limb analysis relies on conventional X-ray (2D view) or computerised tomography (CT) Scan (lying position). However, these methods do not allow 3D analysis in standing position. The aim of this study is to propose a fast and accurate 3D-reconstruction-method based on parametric models and statistical inferences from biplanar X-rays with clinical measurements' (CM) assessment in standing position for a clinical routine use. For the reproducibility study, the 95% CI was under 2.7° for all lower limbs' angular measurements except for tibial torsion, femoral torsion and tibiofemoral rotation ( < 5°). The 95% CI were under 2.5 mm for lower limbs' lengths and 1.5 to 3° for the pelvis' CM. Comparisons between X-rays and CT-scan based 3D shapes in vitro showed mean differences of 1.0 mm (95% CI = 2.4 mm). Comparisons of 2D lower limbs' and 3D pelvis' CM between standing 'Shifted-Feet' and 'Non-Shifted-Feet' position showed means differences of 0.0 to 1.4°. Significant differences were found only for pelvic obliquity and rotation. The reconstruction time was about 5 min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Glüer, C. C., Blake, G., Lu, Y., Blunt1, B. A., Jergas1, M., & Genant1, H. K. (1995) · Osteoporosis International · doi:10.1007/bf01774016 · Cited by 1,282
Radiographic analysis of the axial alignment of the lower extremity.
Moreland, J. R., Bassett, L. W., & Hanker, G. J. (1987) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198769050-00016 · Cited by 973
The anatomy and functional axes of the femur.
Yoshioka, Y., Siu, D., & Cooke, T. D. (1987) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198769060-00012 · Cited by 508
Une nouvelle imagerie Ostéo-Articulaire basse dose en position debout : le système EOS
Dubousset, J., Charpak, G., Dorion, I., Skalli, W., Lavaste, F., Deguise, J., Kalifa, G., & Ferey, S. (2005) · Bulletin de l'Académie Nationale de Médecine · doi:10.1016/s0001-4079(19)33584-8 · Cited by 305
Self-citationTibial anatomy and functional axes
Yoshioka, Y., Siu, D. W., Scudamore, R. A., & Cooke, T. D. V. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070118 · Cited by 265
26th Annual International Conference of the IEEE EMBS
Wang, L., Hammond, P., Johannessen, E. A., Tang, T. B., Astaras, A., Beaumont, S., Murray, A., Cooper, J. M., & Cumming, D. R. S. (2004) · Cited by 211
Jiang, C., & Insall, J. N. (1989) · PubMed · Cited by 123
Three-dimensional lower extremity alignment assessment system
Satō, T., Koga, Y., & Omori, G. (2004) · The Journal of Arthroplasty · doi:10.1016/j.arth.2003.12.063 · Cited by 117
Predictive geometric factors in a standardized model of femoral neck fracture
Kukla, C., Gaebler, C., Pichl, R. W., PROKESCH, R. W., Heinze, G., & Heinz, T. (2002) · Injury · doi:10.1016/s0020-1383(02)00076-1 · Cited by 49
Metadata
- Authors
- Chaibi, Y., Cresson, T., Aubert, B., Hausselle, J., Neyret, P., Hauger, O., de Guise, J. A., & Skalli, W.
- Venue
- Computer Methods in Biomechanics and Biomedical Engineering
- Publisher
- Informa UK Limited
- Published
- 2012-05
- Volume
- 15
- Issue
- 5
- Pages
- 457-466
- ISSN
- 1025-5842 (ISSN-L)
- 1476-8259
- OpenAlex
- W2041571426
- Cited by
- 255
- References
- 11
- FWCI
- 8.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays. https://app.cochat.ai/papers/10.1080/10255842.2010.540758
- The paper
- Chaibi, Y., Cresson, T., Aubert, B., Hausselle, J., Neyret, P., Hauger, O., de Guise, J. A., & Skalli, W. (2012). Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays. Computer Methods in Biomechanics and Biomedical Engineering. https://doi.org/10.1080/10255842.2010.540758
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.