Grey water in buildings: a mini-review of guidelines, technologies and case studies
Abstract
The aim of the work is to describe the state-of-the-art on the reuse of grey water at building level taking into account (i) the grey water characteristics and amounts produced, (ii) the recycling guidelines, (iii) the treatment systems and reuse technologies, also considering the removal of micro-pollutants as xenobiotic organic compounds, and (iv) an overview of case studies for developed countries. The mini-review highlights how the existing technologies allow the safe reuse of grey water. Attention must be given to the removal of micro-pollutants especially when the discharge takes place in surface water. With reference to 12 case studies of buildings which adopt non-conventional technologies with the aim to optimise energy consumptions, results showed how the use of non-conventional technologies for water is very limited. However, adopting an integrated approach to water-energy, it is possible to use more effectively the water for energy purposes as in the cases of cooling/heating systems.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Meanwhile, inappropriate disposal of greywater has serious environmental and public health risks, especially via exposure to harmful contaminants like pathogens (microbes), nutrients to cause eutrophication, surfactants, heavy metals, micropollutants (xenobiotic compounds) etc. [8,39,48] .”
From Domestic greywater flows and pollutant loads: A neighbourhood study within a university campus in Ghana (2020) · cites this paper as [8]
In the citing paper
“EPA-Gh has no discharge limit for anionic surfactants, a micropollutant commonly found in detergents [8] but their levels fell on the lower side of other findings (7 -436 mg/L) in a European setting [36] .”
From Domestic greywater flows and pollutant loads: A neighbourhood study within a university campus in Ghana (2020) · cites this paper as [8]
Citations
Cites
Wastewater engineering : treatment and reuse
Metcalf, & Eddy (2004) · McGraw-Hill eBooks · Cited by 9,028
Characteristics of grey wastewater
Eriksson, E., Auffarth, K., Henze, M., & Ledin, A. (2002) · Urban Water · doi:10.1016/s1462-0758(01)00064-4 · Cited by 951 · cited 5×
“coliform (> 99%) Guidelines: A = Nolde (2000), Germany; B = Ernst et al. (2008), China; C = Asano (2007), USA.”
BackgroundInfluentialReview of the technological approaches for grey water treatment and reuses
Li, F., Wichmann, K., & Otterpohl, R. (2009) · Science of The Total Environment · doi:10.1016/j.scitotenv.2009.02.004 · Cited by 651 · cited 5×
“Consequently, the MBR appears to be an attractive technical solution for grey water recycling, particularly in collective urban residential buildings (Li, Wichmann, and Otterpohl 2009).”
BackgroundInfluentialApplying Integrated Urban Water Management Concepts: A Review of Australian Experience
Mitchell, V. G. (2006) · Environmental Management · doi:10.1007/s00267-004-0252-1 · Cited by 355 · cited 4×
“It is the case of the City of Melbourne, in Australia, with his plan called ‘Melbourne metropolitan sewerage strategy’.”
BackgroundInfluentialNolde, E. (2000) · Urban Water · doi:10.1016/s1462-0758(00)00023-6 · Cited by 344 · cited 4×
“91 – < 59 – – Biological processes Nolde (2000) Sedimentation + RBC + UV disinfection – – – – 100– 430 – 50– 250 < 5 BOD7 5– 10 – 0.”
BackgroundMethodInfluentialGross, A., Shmueli, O., Ronen, Z., & Raveh, E. (2007) · Chemosphere · doi:10.1016/j.chemosphere.2006.06.006 · Cited by 272
Removal of micropollutants from aerobically treated grey water via ozone and activated carbon
Hernández-Leal, L., Temmink, H., Zeeman, G., & Buisman, C. J. N. (2011) · Water Research · doi:10.1016/j.watres.2011.03.009 · Cited by 257
Laundry wastewater treatment using coagulation and membrane filtration
Šostar-Turk, S., Petrinić, I., & Simonič, M. (2005) · Resources, Conservation and Recycling · doi:10.1016/j.resconrec.2004.11.002 · Cited by 251
Chemical solutions for greywater recycling
Pidou, M., Avery, L., Stephenson, T., Jeffrey, P., Parsons, S. A., Liu, S., Memon, F. A., & Jefferson, B. (2008) · Chemosphere · doi:10.1016/j.chemosphere.2007.10.046 · Cited by 179
Experiences on greywater re-use for toilet flushing in a hotel (Mallorca Island, Spain)
March, J. G., Gual, M., & Orozco, F. (2004) · Desalination · doi:10.1016/s0011-9164(04)00192-4 · Cited by 178
Research works printed but not linked: 2
- Ernst M., 2008, Desalination, 202, 221
- Gerba C. P., 1995, Journal of the American Water Resources Association, 18, 78
Cited by
Boano, F., Caruso, A., Costamagna, E., Ridolfi, L., Fiore, S., Demichelis, F., Galvão, A., Pisoeiro, J., Rizzo, A., & Masi, F. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2019.134731 · Cited by 337
Constructed wetlands for greywater recycle and reuse: A review
Arden, S., & Ma, X. (2018) · Science of The Total Environment · doi:10.1016/j.scitotenv.2018.02.218 · Cited by 220
Quantitative microbial risk assessment of Greywater on-site reuse
Shi, K.-W., Wang, C., & Jiang, S. C. (2018) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2018.04.197 · Cited by 143
“Even in bathroom greywater, the concentration of total coliforms can exceed 1 × 107 CFU/100 ml (De Gisi et al., 2016), which poses a potential health threat during its practical reuse application.”
BackgroundMethodInfluentialMembrane bioreactors for sustainable, fit-for-purpose greywater treatment: a critical review
Cecconet, D., Callegari, A., Hlavínek, P., & Capodaglio, A. G. (2019) · Clean Technologies and Environmental Policy · doi:10.1007/s10098-019-01679-z · Cited by 111
LCA of greywater management within a water circular economy restorative thinking framework
Dominguez, S., Laso, J., Margallo, M., Aldaco, R., Rivero, M. J., Irabien, Á., & Ortiz, I. (2018) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.10.122 · Cited by 83
Metadata
- Authors
- De Gisi, S., Casella, P., Notarnicola, M., & Farina, R.
- Affiliations
- National Agency for New Technologies, Energy and Sustainable Economic Development (IT)
- Polytechnic University of Bari (IT)
- Venue
- Civil Engineering and Environmental Systems
- Publisher
- Informa UK Limited
- Published
- 2015-12-29
- Volume
- 33
- Issue
- 1
- Pages
- 35-54
- ISSN
- 1028-6608 (ISSN-L)
- 1029-0249
- OpenAlex
- W2304907012
- Cited by
- 96
- References
- 33
- Citations by year
- 2026: 5 · 2025: 9 · 2024: 14 · 2023: 9 · 2022: 10 · 2021: 13 · 2020: 15 · 2019: 6 · 2018: 8 · 2017: 5 · 2016: 2
- FWCI
- 0.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Civil Engineering and Environmental Systems (publishedVersion)
- ENEA Open Archive (National Agency for New Technologies, Energy and Sustainable Economic Development) (submittedVersion)
- Topics
- Physical Sciences › Environmental Science › Waste Management and Disposal › Wastewater Treatment and Reuse
- Physical Sciences › Environmental Science › Environmental Engineering › Urban Stormwater Management Solutions
- Physical Sciences › Environmental Science › Waste Management and Disposal › Constructed Wetlands for Wastewater Treatment
- Keywords
- greywater, greywater reuse, micropollutant removal, xenobiotic organic compounds, water-energy nexus, heating and cooling, water conservation, surface water discharge
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Grey water in buildings: a mini-review of guidelines, technologies and case studies. https://app.cochat.ai/papers/10.1080/10286608.2015.1124868
- The paper
- De Gisi, S., Casella, P., Notarnicola, M., & Farina, R. (2016). Grey water in buildings: a mini-review of guidelines, technologies and case studies. Civil Engineering and Environmental Systems. https://doi.org/10.1080/10286608.2015.1124868
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.