A Review on Solid Phase Micro Extraction—High Performance Liquid Chromatography (SPME-HPLC) Analysis of Pesticides
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Pesticides are an important and diverse environmental and agricultural species. Their determination in formulations, in feed and food, and in complex environmental matrices (e.g., water, soil, sludge, sediments, etc.) often requires separation methods capable of high efficiency, unique selectivity, and high sensitivity. Because pesticides (organophosporus, organochlorine, carbamate, dithiocarbamate, etc.) are carcinogenic, they are problematic for humans in the course of the food chain. Residual analyses have been performed to find out the concentration and type of pesticides and their metabolites left in food at the time of consumption. This ultimately helps in production of better and human-friendly pesticides. A new and effective sampling technique, Solid-Phase microextraction (SPME), was developed in 1990 using a fused silica fiber coated on the outside with appropriate stationary phase in which analyte in the sample is directly extracted to the fibber coating. Two types of fiber techniques can be used to extract analytes: Headspace (HS-SPME), where the fiber is exposed to the vapor phase above a gas, and direct immersion (DI-SPME), where the fiber is directly immersed in the samples. More advanced in-tube SPME recently has been developed, which uses open tubular fused-silica capillary column instead of SPME fiber. SPME in combination with HPLC, GC, GC-MS, LC-MS is getting a wide acceptability as an analytical technique. These have great advantages over the classical sampling techniques, which are time consuming and require larger samples and solvents. This review discusses the various advantages and disadvantages of the SPME for the extraction of the pesticides and their analysis by HPLC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solid phase microextraction with thermal desorption using fused silica optical fibers
Arthur, C. L., & Pawliszyn, J. (1990) · Analytical Chemistry · doi:10.1021/ac00218a019 · Cited by 4,997 · cited 1×
“Solid-phase microextraction is relatively a new approach invented and developed at the University of Waterloo (Ontario, Canada) by Pawliszyn and Associates (Belardi and Pawliszyn) and being sold by Supelco( 1 , 2 ).”
BackgroundApplications of solid-phase microextraction in food analysis
Kataoka, H., Lord, H. L., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00309-5 · Cited by 1,119
Solid-Phase Microextraction. A Solvent-Free Alternative for Sample Preparation
Zhang, Z., Yang, M. J., & Pawliszyn, J. (1994) · Analytical Chemistry · doi:10.1021/ac00089a001 · Cited by 763
Dynamics of organic compound extraction from water using liquid-coated fused silica fibers
Louch, D., Motlagh, S., & Pawliszyn, J. (1992) · Analytical Chemistry · doi:10.1021/ac00034a020 · Cited by 603 · cited 1×
“A conventional SPME-HPLC interface ( 13 ) reported by Pawliszyn et al.”
MethodSolid Phase Microextraction for Quantitative Analysis in Nonequilibrium Situations
Ai, J. (1997) · Analytical Chemistry · doi:10.1021/ac9609541 · Cited by 359 · cited 1×
“Although SPME has a maximum sensitivity at partition equilibrium, a proportional relationship is obtained between the amount of analyte adsorbed by the SPME fiber and the initial concentration in the sample matrix before reaching partition equilibrium ( 9 , 10 ), which implies that full equilibration is not necessary…”
BackgroundQuantitative Extraction Using an Internally Cooled Solid Phase Microextraction Device
Zhang, Z., & Pawliszyn, J. (1995) · Analytical Chemistry · doi:10.1021/ac00097a007 · Cited by 335
Solid Phase Microextraction Coupled to High-Performance Liquid Chromatography
Chen, J., & Pawliszyn, J. B. (1995) · Analytical Chemistry · doi:10.1021/ac00111a006 · Cited by 310
Martos, P. A., & Pawliszyn, J. (1998) · Analytical Chemistry · doi:10.1021/ac9711394 · Cited by 240
Derivatization/Solid-Phase Microextraction: New Approach to Polar Analytes
Pan, L., & Pawliszyn, J. (1997) · Analytical Chemistry · doi:10.1021/ac9606362 · Cited by 211
Ai, J. (1997) · Analytical Chemistry · doi:10.1021/ac970024x · Cited by 196 · cited 1×
“Although SPME has a maximum sensitivity at partition equilibrium, a proportional relationship is obtained between the amount of analyte adsorbed by the SPME fiber and the initial concentration in the sample matrix before reaching partition equilibrium ( 9 , 10 ), which implies that full equilibration is not necessary…”
BackgroundMeasurement of the Free Concentration Using Solid-Phase Microextraction: Binding to Protein
Vaes, W. H. J., Urrestarazu Ramos, E., Verhaar, H. J. M., Seinen, W., & Hermens, J. L. M. (1996) · Analytical Chemistry · doi:10.1021/ac960337c · Cited by 180 · cited 1×
“Hence, it can be applied for measuring freely dissolved concentration (28) and partition coefficients (29).”
BackgroundVaes, W. H. J., Urrestarazu Ramos, E., Hamwijk, C., van Holsteijn, I., Blaauboer, B. J., Seinen, W., Verhaar, H. J. M., & Hermens, J. L. M. (1997) · Chemical Research in Toxicology · doi:10.1021/tx970109t · Cited by 151
Gou, Y., Eisert, R., & Pawliszyn, J. B. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)01125-5 · Cited by 138 · cited 1×
“Detection of carbaryl present in clean water samples at 1 ng/l was possible ( 33 ).”
BackgroundJinno, K., Muramatsu, T., Saito, Y., Kiso, Y., Magdic, S., & Pawliszyn, J. B. (1996) · Journal of Chromatography A · doi:10.1016/s0021-9673(96)00212-9 · Cited by 130
Development of new SPME fibers by sol–gel technology for SPME-HPLC determination of organometals
Gbatu, T. P., Sutton, K. L., & Caruso, J. A. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00532-2 · Cited by 126 · cited 2×
“Some modification of the fiber report using sol gel process (26), these fibers are stable in strong organic solvents (xylene and methylene chloride) as well as acidic and basic solutions.”
MethodLützhøft, H. H., Vaes, W. H. J., Freidig, A. P., Halling‐Sørensen, B., & Hermens, J. L. M. (2000) · Environmental Science & Technology · doi:10.1021/es000917y · Cited by 110
Llompart, M., Li, K., & Fingas, M. F. (1998) · Analytical Chemistry · doi:10.1021/ac971332y · Cited by 96 · cited 1×
“Also adsorption of many chemical species like PCBs ( 11 ) on the fiber is a slow process and sampling may take several days.”
BackgroundFalqui-Cao, C., Wang, Z., Urruty, L., Pommier, J.-J., & Montury, M. (2001) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf010519u · Cited by 91
Jinno, K., Taniguchi, M., & Hayashida, M. (1998) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(98)00074-0 · Cited by 80
Eisert, R., & Pawliszyn, J. B. (1997) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)00332-4 · Cited by 68
Kelly, M. T., & Larroque, M. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00282-4 · Cited by 66
Kumazawa, T., Seno, H., Watanabe‐Suzuki, K., Hattori, H., Ishii, A., Sato, K., & Suzuki, O. (2000) · Journal of Mass Spectrometry · Cited by 66 · cited 2×
“Phenothiazines in human bodily fluids (19), polar pesticides in soil (21) and other pesticides (20) were analyzed with a polyacrylate-coated fiber.”
MethodTakino, M., Daishima, S., & Nakahara, T. (2001) · The Analyst · doi:10.1039/b100380l · Cited by 56 · cited 1×
“A method for the determination of chlorinated phenoxy acid herbicides ( 40 ) in river water has been developed using in-tube SPME followed by LC/ESI-MS.”
MethodZambonin, C. G., Monaci, L., & Aresta, A. M. (2001) · Food Chemistry · doi:10.1016/s0308-8146(01)00218-7 · Cited by 54
Gou, Y., Tragas, C., Lord, H. L., & Pawliszyn, J. B. (2000) · Journal of Microcolumn Separations · doi:10.1002/(sici)1520-667x(2000)12:3<125::aid-mcs1>3.0.co;2-9 · Cited by 50 · cited 1×
“Comparison of two commercially available autosamplers were made ( 32 ) for online coupling of in-tube SPME to HPLC for analysis of carbamates in water samples.”
MethodWu, J., Mester, Z., & Pawliszyn, J. B. (2001) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b007321k · Cited by 43 · cited 1×
“A simple and sensitive method has been developed ( 36 ) for the determination of tributyltin (TBT) in aqueous samples and environmental samples.”
MethodMester, Z., Lord, H. L., & Pawliszyn, J. B. (2000) · Journal of Analytical Atomic Spectrometry · doi:10.1039/a910210h · Cited by 38 · cited 1×
“An analytical method has been developed for the determination of the trimethyllead (TML) and triethyllead (TEL) species in aqueous samples ( 35 ).”
MethodLiao, J., Zeng, C., Hjertén, S., & Pawliszyn, J. B. (1996) · Journal of Microcolumn Separations · doi:10.1002/(sici)1520-667x(1996)8:1<1::aid-mcs1>3.0.co;2-5 · Cited by 34 · cited 1×
“Liao et al ( 31 ) reported a method in which fused-silica fiber after being activated in ethacryloxypropyltrimethoxysilane and coated with polyacrylic acid by immersing in 0.”
MethodAranda‐Rodriguez, R., Kruus, P., & Burk, R. C. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00490-8 · Cited by 34 · cited 1×
“(30) using polycrystalline graphites (pencil lead and vitreous carbon) as sorbents for SPME of a nonionic alkylphenol ethoxylate surfactant (Triton X-100).”
BackgroundOptimisation of alachlor solid-phase microextraction from water samples using experimental design
González‐Barreiro, C., Lores, M., Casais, M. C., & Cela, R. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00679-8 · Cited by 34
Wang, Z., Hennion, B., Urruty, L., & Montury, M. (2000) · Food Additives & Contaminants · doi:10.1080/026520300750038090 · Cited by 34 · cited 1×
“Methiocarb, napropamide, fenoxycarb, and bupirimate were analyzed ( 45 ) ( Figure 5 ) from spiked strawberry samples using polydimethylsiloxane/divinylbenzene-coated silica fiber and photodiode-array detection at 205 nm and 240 nm.”
MethodDaimon, H., & Pawliszyn, J. B. (1997) · Analytical Communications · doi:10.1039/a704729k · Cited by 18 · cited 1×
“Two type of desorption techniques are used depending on the nature of interaction between analyte and fiber: static desorption ( 14 , 15 ) and dynamic desorption.”
MethodKatayama, M., Matsuda, Y., Shimokawa, K., Tanabe, S., Hara, I., Sato, T., Kaneko, S., & Daimon, H. (2001) · Analytical Letters · doi:10.1081/al-100002707 · Cited by 17
Eisert, R., Jackson, S. H., & Krotzky, A. J. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)01026-8 · Cited by 14
Cited by
Review of surface enhanced Raman spectroscopic (SERS) detection of synthetic chemical pesticides
Pang, S., Yang, T., & He, L. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.06.017 · Cited by 468
Cui, X.-Y., Gu, Z.-Y., Jiang, D.-Q., Li, Y., Wang, H.-F., & Yan, X.-P. (2009) · Analytical Chemistry · doi:10.1021/ac901663x · Cited by 381
Sample preparation techniques for the determination of trace residues and contaminants in foods
Ridgway, K., Lalljie, S. P. D., & Smith, R. M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.01.134 · Cited by 354
Supramolecular solvents in the extraction of organic compounds. A review
Ballesteros-Gómez, A., Sicilia, M. D., & Rubio, S. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.07.027 · Cited by 320
A comprehensive look at solid-phase microextraction technique: A review of reviews
Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020) · Microchemical Journal · doi:10.1016/j.microc.2019.104319 · Cited by 317
Metadata
- Authors
- Aulakh, J. S., Malik, A. K., Kaur, V., & Schmitt-Kopplin, P.
- Venue
- Critical Reviews in Analytical Chemistry
- Publisher
- Informa UK Limited
- Published
- 2005-01
- Volume
- 35
- Issue
- 1
- Pages
- 71-85
- ISSN
- 1040-8347 (ISSN-L)
- 1547-6510
- OpenAlex
- W1963635488
- Cited by
- 195
- References
- 34
- FWCI
- 7.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.