The Kinetics of Metal Solvent Extraction
The DOI matches its Crossref record.
Abstract
The kinetics of solvent extraction of metal species by organic solution of acidic, basic, and neutral reagents has been reviewed by considering the contribution of both chemical reactions and transport processes on the rate of extraction. The relative predominance of slow chemical reactions and diffusion processes has been shown to depend, in a critical way, both on the hydrodynamic conditions present in the extracting apparatus and on the specific nature and composition of the chemical system involved in the extraction. The general criteria that can help to distinguish between extraction kinetics controlled either by mass transport or chemical reactions have been reviewed. These criteria involve the experimental determination of the influence of a rather large number of physical and chemical variables on the rate of extraction and do not always lead to unambiguous conclusions. The reviewed literature has allowed to draw the following conclusions: (1) because of a lack of complete characterization (especially in terms of hydrodynamics, interfacial pressure, and sufficiently wide concentration ranges), much of the early work on solvent extraction kinetics has rarely led to the definite identification of the rate determining processes; as a consequence, correct extrapolation to the different experimental conditions that are met in practicalmore » analytical or technological separations has been often impossible; and (2) more recently a certain number of extraction kinetics studies have appeared which have been carried out in hydrodynamically controlled conditions, exploring a large range of compositions of the species and with knowledge of the interfacial properties of the biphasic system; such studies have contributed to the emergence of a general pattern for the solvent extraction kinetics which is summarized.« less
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Separation of Metal Species by Supported Liquid Membranes
Danesi, P. R. (1984) · Separation Science and Technology · doi:10.1080/01496398408068598 · Cited by 620
Self-citationAnalytical applications of organized molecular assemblies
Pelizzetti, E., & Pramauro, E. (1985) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)86203-0 · Cited by 314
Jiang, X., & Lee, H. K. (2004) · Analytical Chemistry · doi:10.1021/ac040069f · Cited by 217
Ma, M., & Cantwell, F. F. (1998) · Analytical Chemistry · doi:10.1021/ac980174n · Cited by 167
El-Hefny, N. E., El-Nadi, Y. A., & Daoud, J. A. (2010) · Separation and Purification Technology · doi:10.1016/j.seppur.2010.08.020 · Cited by 75
El-Hefny, N. E. (2010) · Chemical Engineering and Processing: Process Intensification · doi:10.1016/j.cep.2009.11.012 · Cited by 25
Szymanowski, J., & Voelkel, A. (1992) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.280540105 · Cited by 17
Metadata
- Authors
- Danesi, P. R., Chiarizia, R., & Coleman, C. F.
- Venue
- Critical Reviews in Analytical Chemistry
- Publisher
- Informa UK Limited
- Published
- 1980-11-01
- Volume
- 10
- Issue
- 1
- Pages
- 1-126
- ISSN
- 1040-8347 (ISSN-L)
- OpenAlex
- W8741696
- Cited by
- 222
- References
- 0
- FWCI
- 8.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.