UV-LED Photo-activated Chemical Gas Sensors: A Review
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Metal oxide semiconductor gas sensors operating under UV irradiation have been validated for detection of variety of chemicals in wide ranges of concentrations at room temperature. This article reviews recent advances in UV-activated metal oxide gas sensors in general and outlines the operating principles and sensing performance of UV-LED based sensors in particular. The sensing properties of several metal oxide semiconductors such as ZnO, TiO2, SnO2, In2O3, and metal oxide composites under UV-LED irradiation are individually presented and their advantages and shortcomings toward various gases are compared. Moreover, it is demonstrated that for the UV-LED based gas sensors, the performance can be improved by optimizing the sensor platform design and UV source parameters such as wavelength and power intensity. Further, it is illustrated that the gas sensing selectivity can be tuned by modifying the semiconductor layer structure or adjusting appropriate wavelength to an optimal value.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human health effects of air pollution
Kampa, M., & Castanas, E. (2008) · Environmental Pollution · doi:10.1016/j.envpol.2007.06.012 · Cited by 4,496
Metal Oxide Gas Sensors: Sensitivity and Influencing Factors
Wang, C., Yin, L., Zhang, L., Xiang, D., & Gao, R. (2010) · Sensors · doi:10.3390/s100302088 · Cited by 2,928
Conduction Model of Metal Oxide Gas Sensors
Barsan, N., & Weimar, U. (2001) · Journal of Electroceramics · doi:10.1023/a:1014405811371 · Cited by 2,721
The surface and materials science of tin oxide
Batzill, M., & Diebold, U. (2005) · Progress in Surface Science · doi:10.1016/j.progsurf.2005.09.002 · Cited by 2,557
A New Detector for Gaseous Components Using Semiconductive Thin Films.
Seiyama, T., Kato, A., Fujiishi, K., & Nagatani, M. (1962) · Analytical Chemistry · doi:10.1021/ac60191a001 · Cited by 1,486
Grain size effects on gas sensitivity of porous SnO2-based elements
Xu, C., Tamaki, J., Miura, N., & Yamazoe, N. (1991) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(91)80207-z · Cited by 1,426
Oxide Semiconductor Gas Sensors
Yamazoe, N., Sakai, G., & Shimanoe, K. (2003) · Catalysis Surveys from Asia · doi:10.1023/a:1023436725457 · Cited by 1,291
Semiconducting metal oxides as sensors for environmentally hazardous gases
Wetchakun, K., Samerjai, T., Tamaekong, N., Liewhiran, C., Siriwong, C., Kruefu, V., Wisitsoraat, A., Tuantranont, A., & Phanichphant, S. (2011) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2011.08.032 · Cited by 1,241
Standardization of Methods for Fluence (UV Dose) Determination in Bench-Scale UV Experiments
Bolton, J. R., & Linden, K. G. (2003) · Journal of Environmental Engineering · doi:10.1061/(asce)0733-9372(2003)129:3(209 · Cited by 1,215
Application of ultraviolet light-emitting diodes (UV-LEDs) for water disinfection: A review
Song, K., Mohseni, M., & Taghipour, F. (2016) · Water Research · doi:10.1016/j.watres.2016.03.003 · Cited by 858
Self-citation
Cited by
Recent advances in energy-saving chemiresistive gas sensors: A review
Majhi, S. M., Mirzaei, A., Kim, H. W., Kim, S. S., & Kim, T. W. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105369 · Cited by 653
“Also UV-irradiation is a good technique to reduce the sensing temperature [149,150].”
Room-Temperature Gas Sensors Under Photoactivation: From Metal Oxides to 2D Materials
Kumar, R., Liu, X., Zhang, J., & Kumar, M. (2020) · Nano-Micro Letters · doi:10.1007/s40820-020-00503-4 · Cited by 413
Functional gas sensing nanomaterials: A panoramic view
Malik, R., Tomer, V. K., Mishra, Y. K., & Lin, L. (2020) · Applied Physics Reviews · doi:10.1063/1.5123479 · Cited by 410
Wasisto, H. S., Prades, J. D., Gülink, J., & Waag, A. (2019) · Applied Physics Reviews · doi:10.1063/1.5096322 · Cited by 309
Gas sensing performance of 2D nanomaterials/metal oxide nanocomposites: a review
Bhati, V. S., Kumar, M., & Banerjee, R. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc01857d · Cited by 256
Resistive gas sensors based on metal-oxide nanowires
Mirzaei, A., Lee, J.-H., Majhi, S. M., Weber, M., Bechelany, M., Kim, H. W., & Kim, S. S. (2019) · Journal of Applied Physics · doi:10.1063/1.5118805 · Cited by 248
Tang, H., Sacco, L. N., Vollebregt, S., Ye, H., Fan, X., & Zhang, G. (2020) · Journal of Materials Chemistry A · doi:10.1039/d0ta08190f · Cited by 223
Wang, J., Shen, H., Xia, Y., & Komarneni, S. (2021) · Ceramics International · doi:10.1016/j.ceramint.2020.11.187 · Cited by 178
Mirzaei, A., Yousefi, H. R., Falsafi, F., Bonyani, M., Lee, J.-H., Kim, J.-H., Kim, H. W., & Kim, S. S. (2019) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2019.05.180 · Cited by 175
Huang, L., Cai, G., Zeng, R., Yu, Z., & Tang, D. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c02010 · Cited by 171
Niu, Y., Zeng, J., Liu, X., Li, J., Wang, Q., Li, H., Rooij, N. F. D., Wang, Y., & Zhou, G. (2021) · Advanced Science · doi:10.1002/advs.202100472 · Cited by 164
Metadata
- Authors
- Espid, E., & Taghipour, F.
- Venue
- Critical Reviews in Solid State and Materials Sciences
- Publisher
- Informa UK Limited
- Published
- 2016-11-10
- Volume
- 42
- Issue
- 5
- Pages
- 416-432
- ISSN
- 0161-1593 (ISSN-L)
- 1040-8436
- 1547-6561
- OpenAlex
- W2553710661
- Cited by
- 268
- References
- 43
- FWCI
- 6.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.