Does Embodiment Matter to Biomechanics and Function? A Comparative Analysis of Head-Mounted and Hand-Held Assistive Devices for Individuals with Blindness and Low Vision
Open accessAbstract
Visual assistive technologies like Microsoft’s Seeing AI can improve access to environmental information for persons with Blindness or Low Vision (pBLV). Yet, the physical and functional implications of different device embodiments remain unclear. Eleven pBLV participants used Seeing AI on a hand-held smartphone and a head-mounted ARx Vision system to perform six activities of daily living, while movements were captured with Xsens motion capture. Functional outcomes included task time, success rate, and attempt count; biomechanical measures included joint range of motion, angular path length, working volume, and movement smoothness. The head-mounted system generally reduced upper-body movement and task time, especially for document-scanning tasks, whereas the hand-held system yielded higher success rates for small or curved text. Both embodiments are viable, differing in physical demands and ease of use. Incorporating biomechanical measures into assistive technology evaluations can inform designs optimizing user experience, balancing functional efficiency, physical sustainability, and intuitive interaction.
Checked 2026-10-11 · 10 references not checked yet
Overview
CoChat Summary
TL;DR
In 11 people with blindness or low vision, a head-mounted Seeing AI setup generally reduced upper-body movement and task time, while a hand-held smartphone setup generally achieved higher success rates and fewer attempts. The two embodiments were both viable, but they traded off ergonomic efficiency against ease of successful completion.
Key findings
- In the final-attempt analysis, task completion time was generally faster with the head-mounted system, with significant reductions in the Article reading and Person tasks; global task time was also significantly lower for head-mounted use.
- The hand-held system had higher success rates for the Article, Invoice, and Medicine Identification tasks, with global completion rates of 86.37% for head-mounted vs 95.46% for hand-held.
- The head-mounted system required more attempts on average, especially for Invoice, Product, and Article tasks; global average attempts were 1.4 for head-mounted vs 1.2 for hand-held.
- Biomechanically, the hand-held system produced larger movement demands: the paper reports a 35% greater trunk ROM, 75% greater right-hand working volume, 60% greater left-hand working volume, and 500% greater head working volume compared with the head-mounted system.
Methods
- Comparative study with 11 participants with blindness or low vision (7 females, 4 males), using two embodiments of Seeing AI: a head-mounted ARx Vision system and a hand-held Google Pixel 4 smartphone.
- Participants completed six ADL-like tasks: article reading, invoice reading, medicine identification, product identification, person detection, and street sign identification; embodiment order was counterbalanced.
- Upper-body movement was recorded with Xsens MVN Awinda motion capture. Analyses focused on the final attempt plus a secondary summative analysis across all attempts, using Wilcoxon signed-rank tests with Benjamini-Hochberg correction after excluding outliers beyond 3 SD.
Limitations
- The paper states that the study had a relatively small sample size and short-term exposure to each device, so it may not reflect long-term use.
- The hand-held condition used a smartphone with substantially better camera quality than the head-mounted camera, which the authors say likely affected OCR performance, especially for curved surfaces.
- The authors also note that participants may have been more familiar with smartphones than head-mounted interfaces, which could bias performance toward the hand-held system.
- Evident from the text: some outcomes are reported descriptively or without inferential testing for certain count measures, and the sample spans varied visual impairment causes and acuity levels, which may limit generalizability.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 11 Not checked · 135 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“For the number of attempts, the head-mounted system required more attempts on average, especially in the Invoice, Product, and Article tasks.”
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“However, the hand-held system showed higher success rates in the Article, Invoice, and Medicine Identification tasks, contributing to a higher global completion rate overall (HM: 86.37%, HH: 95.46%)”
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The head-mounted system generally reduced upper-body movement and task time, especially for document-scanning style tasks, whereas the hand-held system yielded higher success rates for tasks involving small or curved text.”
plainstates a causen = 11- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Task completion time was generally faster with the head-mounted (HM) as compared to hand-held (HH) system, with significant reductions observed in the Article reading and Person tasks.”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“This trend was reflected in the global task time, which was also significantly lower for the head-mounted system (Figure 3A, Table 2).”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
75 more claims
Create a free account to see all 146 claims and to verify the 25 references still open.
- It may state two separate claims as one. 41
- The quote only partly states this claim. 4
- Probably not a substantial claim. 29
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482 · cited 1×
“To control the false discovery rate during multiple comparisons, Benjamini-Hochberg (BH) correction was applied (Benjamini and Hochberg 1995).”
Effects of smartphone overuse on hand function, pinch strength, and the median nerve
İNal, E. E., Demİrcİ, K., Çetİntürk, A., Akgönül, M., & Savaş, S. (2015) · Muscle & Nerve · doi:10.1002/mus.24695 · Cited by 230 · cited 1×
“…by evidence linking smartphone overuse to musculoskeletal disorders, including neck pain, hand dysfunction, and upper limb strain (Eitivipart, Viriyarojanakul, and Redhead 2018; Barrett, McKinnon, and Callaghan 2020; İnal et al. 2015; Soliman Elserty, Ahmed Helmy, and Mohmed Mounir 2020) .”
Eitivipart, A. C., Viriyarojanakul, S., & Redhead, L. (2018) · Hong Kong Physiotherapy Journal · doi:10.1142/s1013702518300010 · Cited by 198 · cited 1×
“…are supported by evidence linking smartphone overuse to musculoskeletal disorders, including neck pain, hand dysfunction, and upper limb strain (Eitivipart, Viriyarojanakul, and Redhead 2018; Barrett, McKinnon, and Callaghan 2020; İnal et al. 2015; Soliman Elserty, Ahmed Helmy, and Mohmed…”
Timed Instrumental Activities of Daily Living Tasks: Relationship to Visual Function in Older Adults
Owsley, C. J., McGwin, G., Sloane, M. E., Stalvey, B. T., & WELLS, A. J. (2001) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2001.tb01267.x · Cited by 171
Current and future mobile and wearable device use by people with visual impairments
Ye, H., Malu, M., Oh, U., & Findlater, L. (2014) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/2556288.2557085 · Cited by 148 · cited 2×
“…user surveys, pBLV have reported a preference for smart glasses over smartphones for reasons including hands-free operation, natural gaze alignment, and improved usability for specific populations like guide-dog users and musicians (Gamage et al. 2023; Lussier-Dalpé et al. 2022; Hanlu et al. 2014).”
Estimating Movement Smoothness From Inertial Measurement Units
Melendez-Calderon, A., Shirota, C., & Balasubramanian, S. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.558771 · Cited by 114
Plikynas, D., Žvironas, A., Budrionis, A., & Gudauskis, M. (2020) · Sensors · doi:10.3390/s20030636 · Cited by 100 · cited 2×
“Moreover, effective and efficient environmental-interaction tools are essential to promoting independence in pBLV (Golubova et al. 2021; Plikynas et al. 2020).”
Jerk as an indicator of physical exertion and fatigue
Zhang, L., Diraneyya, M. M., Ryu, J., Haas, C. T., & Abdel-Rahman, E. M. (2019) · Automation in Construction · doi:10.1016/j.autcon.2019.04.016 · Cited by 94 · cited 1×
“This distinction in movement quantity is not merely a matter of efficiency; it has important implications for fatigue, overuse, and long-term accessibility (Wong, Cluff, and Kuo 2021; Fang et al. 2007; Zhang et al. 2019).”
Clinical performance of electronic, head‐mounted, low‐vision devices
Culham, L. E., Chabra, A., & Rubin, G. S. (2004) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2004.00193.x · Cited by 83
Review—Emerging Portable Technologies for Gait Analysis in Neurological Disorders
Salchow-Hömmen, C., Skrobot, M., Jochner, M. C. E., Schauer, T., Kühn, A. A., & Wenger, N. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.768575 · Cited by 73
Research works printed but not linked: 1
- 10.1145/3411764.3445451 · DOI
Cited by
Feng, J., Ballem, N., Beheshti, M., Hamilton-Fletcher, G., Hudson, T. E., Porfiri, M., Seiple, W., & Rizzo, J. (2026) · Disability and Rehabilitation Assistive Technology · doi:10.1080/17483107.2026.2673178 · Cited by 5
“The main camera generally maintains higher and more stable accuracy, while the ultra-wide camera shows greater variability and lower performance, especially at the start of the approach and under faster walking speeds.”
Self-citationAccelerating responsibly: From novelty to necessity in visual assistive technology
Kempapidis, T., Manduchi, R., & Rizzo, J. (2026) · Assistive Technology · doi:10.1080/10400435.2026.2686543
Self-citation
Metadata
- Authors
- Seth, G., Pham, H., Hamilton-Fletcher, G., Leclercq, C., & Rizzo, J.-R.
- Affiliations
- New York University (US)
- NYU Langone Health (US)
- ARxVision LLC
- Corresponding author
- Seth, Gaurav
- Venue
- International Journal of Human–Computer Interaction
- Publisher
- Informa UK Limited
- Published
- 2026-04-23
- Pages
- 1-20
- ISSN
- 1044-7318 (ISSN-L)
- 1532-7590
- OpenAlex
- W4416257737
- Cited by
- 1
- References
- 34
- Citations by year
- 2026: 1
- FWCI
- 17.28
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- International Journal of Human-Computer Interaction (publishedVersion, cc-by)
- arXiv (Cornell University) (submittedVersion, cc-by-nc-nd)
- arXiv (Cornell University)
- Topics
- Health Sciences › Health Professions › Occupational Therapy › Assistive Technology in Communication and Mobility
- Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- assistive technology, blindness, low vision, head-mounted devices, handheld devices, augmented reality, visual impairment, activities of daily living, biomechanics of movement, range of motion, document scanning, user experience
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Does Embodiment Matter to Biomechanics and Function? A Comparative Analysis of Head-Mounted and Hand-Held Assistive Devices for Individuals with Blindness and Low Vision. https://app.cochat.ai/papers/10.1080/10447318.2026.2650557
- The paper
- Seth, G., Pham, H., Hamilton-Fletcher, G., Leclercq, C., & Rizzo, J.-R. (2026). Does Embodiment Matter to Biomechanics and Function? A Comparative Analysis of Head-Mounted and Hand-Held Assistive Devices for Individuals with Blindness and Low Vision. International Journal of Human–Computer Interaction. https://doi.org/10.1080/10447318.2026.2650557
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.