CoChat

Indoor Air Quality in a Middle School, Part II: Development of Emission Factors for Particulate Matter and Bioaerosols

Scheff, Peter A., Paulius, Vidas K., Curtis, Luke, Conroy, Lorraine M. · 2000 · Applied Occupational and Environmental Hygiene
Cited by 97

The DOI matches its Crossref record.

Abstract

A middle school (grades 6 to 8) in a residential section of Springfield, Illinois, with no known air quality problems, was selected for a baseline indoor air quality survey. The study was designed to measure and evaluate air quality at the middle school with the objective of providing a benchmark for comparisons with measurements in schools with potential air quality problems. The focus of this article is on the development of emission factors for particulate matter and bioaerosols. The school was characterized as having no health complaints and good maintenance schedules. Four indoor locations including the cafeteria, a science classroom, an art classroom, the lobby outside the main office, and one outdoor location were sampled for various environmental comfort and pollutant parameters for one week in February 1997. Integrated samples (eight-hour sampling time) for respirable and total particulate matter, and short-term measurements (two-minute samples, three times per day) for bioaerosols were collected on three consecutive days at each of the sampling sites. Continuous measurements of carbon dioxide were logged at all locations for five days. Continuous measurements of respirable particulate matter were also collected in the lobby area. A linear relationship between occupancy and corresponding carbon dioxide and particle concentrations was seen. A completely mixed space, one compartment mass balance model with estimated CO2 generation rates and actual CO2 and particulate matter concentrations was used to model ventilation and pollutant emission rates. Emission factors for occupancy were represented by the slope of emission rate versus occupancy scatter plots. The following particle and bioaerosol emission factors were derived from the indoor measurements: total particles: 1.28 mg/hr/person-hr; respirable particles: 0.154 g/hr/person-hr; total fungi: 167 CFU/hr/person-min; thermophilic fungi: 35.8 CFU/hr/person-min; mesophilic fungi: 119 CFU/hr/person-min; total bacteria: 227 CFU/hr/person-min; gram-negative bacteria: 69.5 CFU/hr/person-min; gram-positive bacteria: 191 CFU/hr/person-min; Aspergillus: 17.0 CFU/hr/person-min; Penicillium: 161 CFU/hr/person-min; and yeasts: 16.4 CFU/hr/person-min.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/10473220050175715

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 97

Metadata

Authors
Scheff, P. A., Paulius, V. K., Curtis, L., & Conroy, L. M.
Venue
Applied Occupational and Environmental Hygiene
Published
2000-01
Volume
15
Issue
11
Pages
835-842
ISSN
  • 1047-322X (ISSN-L)
  • 1521-0898
OpenAlex
W1995305481
Cited by
97
References
0
FWCI
0.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Indoor Air Quality in a Middle School, Part II: Development of Emission Factors for Particulate Matter and Bioaerosols. https://app.cochat.ai/papers/10.1080/10473220050175715
The paper
Scheff, P. A., Paulius, V. K., Curtis, L., & Conroy, L. M. (2000). Indoor Air Quality in a Middle School, Part II: Development of Emission Factors for Particulate Matter and Bioaerosols. Applied Occupational and Environmental Hygiene. https://doi.org/10.1080/10473220050175715

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.