The Magnitude of Bias in the Measurement of PM25 Arising from Volatilization of Particulate Nitrate from Teflon Filters
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Because the Federal Reference Method for PM25 specifies the collection of ambient particles on Teflon filters, we have examined the loss of a known volatile species, particulate nitrate, during sampling. Data are presented from two studies in southern California for which parallel samples were collected by different methods. Differences in collected nitrate are modeled using an evaporation model based on the work of Zhang and McMurry. The average nitrate obtained from sampling with Teflon filters was 28% lower on average than that measured by denuded nylon filters. In contrast, cascade impactor samples were within 5% of the denuded nylon filter on average. A simple model is presented that accounts for the particulate nitrate loss from Teflon filters either by scavenging nitric acid and ammonia in the sampler inlet or by heating the filter substrate during sampling. The observed magnitude of loss is explained by any of the following situations: (1) 100% nitric acid and ammonia vapor loss in the inlet, (2) 5 °C heating of the filter substrate above ambient temperature during sampling, or (3) a combination of these factors, such as 50% vapor loss in the inlet and 3 °C heating of the filter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mozurkewich, M. (1993) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(93)90356-4 · Cited by 324
Modes in the size distributions of atmospheric inorganic aerosol
John, W., Wall, S. M., Ondo, J. L., & Winklmayr, W. (1990) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(90)90327-j · Cited by 269
Characteristics of the Berner Impactor for Sampling Inorganic Ions
Wang, H.-C., & John, W. (1988) · Aerosol Science and Technology · doi:10.1080/02786828808959179 · Cited by 178
A Cyclone for Size-Selective Sampling of Ambient Air
John, W., & Reischl, G. (1980) · Journal of the Air Pollution Control Association · doi:10.1080/00022470.1980.10465122 · Cited by 172
Cited by
Van Dingenen, R., Raes, F., Putaud, J.-P., Baltensperger, U., Charron, A., Facchini, M.-C., Decesari, S., Fuzzi, S., Gehrig, R., Hansson, H.-C., et al. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.01.040 · Cited by 1,011
Putaud, J.-P., Raes, F., Van Dingenen, R., Brüggemann, E., Facchini, M.-C., Decesari, S., Fuzzi, S., Gehrig, R., Hüglin, C., Laj, P., et al. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.01.041 · Cited by 809
Mass reconstruction methods for PM2.5: a review
Chow, J. C., Lowenthal, D. H., Chen, L.-W. A., Wang, X., & Watson, J. G. (2015) · Air Quality, Atmosphere & Health · doi:10.1007/s11869-015-0338-3 · Cited by 379
“However, losses of NH4 + (i.e., gaseous NH3) from nylon filters after a Na2CO3 denuder for the selected six IMPROVE sites ranged from 10 to 28 % (monthly average) during summer.”
BackgroundInfluentialReview on recent progress in observations, source identifications and countermeasures of PM2.5
Liang, C.-S., Duan, F.-K., He, K.-B., & Ma, Y.-L. (2016) · Environment International · doi:10.1016/j.envint.2015.10.016 · Cited by 375
Chemically-resolved aerosol volatility measurements from two megacity field studies
Huffman, J. A., Docherty, K. S., Aiken, A. C., Cubison, M. J., Ulbrich, I. M., DeCarlo, P. F., Sueper, D., Jayne, J. T., Worsnop, D. R., Ziemann, P. J., et al. (2009) · Atmospheric Chemistry and Physics · doi:10.5194/acp-9-7161-2009 · Cited by 334
Metadata
- Authors
- Hering, S., & Cass, G.
- Venue
- Journal of the Air & Waste Management Association
- Publisher
- Informa UK Limited
- Published
- 1999-06
- Volume
- 49
- Issue
- 6
- Pages
- 725-733
- ISSN
- 1047-3289 (ISSN-L)
- 1096-2247
- 2162-2906
- OpenAlex
- W2010565457
- Cited by
- 181
- References
- 4
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.