Direct Linear Transformation Method for Three-Dimensional Cinematography
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This study evaluated the “direct linear transformation” method developed by Abdel-Aziz and Karara (1971) for use with high-speed cine techniques. Two high-speed cameras were used to film a series of points with known spatial coordinates. From knowledge of these “control” points, the parameters representing interior and exterior orientations were determined. The spatial coordinates of unknown points were then calculated. Position data were very accurate. The mean deviations of computed coordinates from the actual coordinates were .4 cm in the vertical direction (Z), .4 cm in the horizontal direction (X), and .5 cm in the horizontal direction (Y). Displacement-time data in the X, Y, and Z directions for the dynamic test were as expected. The calculated vertical accelerations of a ball during free flight were within 1% to 4% of the value of g (−9.8 m/sec2). It was concluded that the photogrammetric method is applicable to cinematographic techniques. Additionally, the flexibility of this technique appeared to be superior to any of the existing three-dimensional cinematographic methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marzan, G. T., & Karara, H. M. (1975) · Cited by 118
Biomechanical Analysis with Cubic Spline Functions
McLaughlin, T. M., Dillman, C. J., & Lardner, T. J. (1977) · Research Quarterly for Exercise and Sport · doi:10.1080/10671315.1977.10615463 · Cited by 48
The Measurement of Three-Dimensional Body Movements by the Use of Photogrammetry
Bullock, B., & HARLEY, T. A. (1972) · Ergonomics · doi:10.1080/00140137208924433 · Cited by 22
Cited by
Comparison of Kinematic and Temporal Parameters between Different Pitch Velocity Groups
Matsuo, T., Escamilla, R. F., Fleisig, G. S., Barrentine, S. W., & Andrews, J. R. (2001) · Journal of Applied Biomechanics · doi:10.1123/jab.17.1.1 · Cited by 298
Computational Modeling of Ligament Mechanics
Weiss, J. A., & Gardiner, J. C. (2001) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v29.i3.20 · Cited by 244
Performance Evaluation of a Harvesting Robot for Sweet Pepper
Bac, C. W., Hemming, J., van Tuijl, B. A. J., Barth, R., Wais, E., & van Henten, E. J. (2017) · Journal of Field Robotics · doi:10.1002/rob.21709 · Cited by 244
“The color image was pixel-wise registered to the ToF image, using the Direct Linear Transformation algorithm (Shapiro, 1978).”
MethodGardiner, J. C., & Weiss, J. A. (2003) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00113-x · Cited by 238
“The marker tracking system was calibrated over a 350 cm 3 volume using the direct linear transformation method [38], allowing the 3D coordinates of the markers to be tracked to within ±0.1 mm during all testing [10].”
MethodInfluentialMechanical output of the cat soleus during treadmill locomotion: In vivo vs in situ characteristics
Gregor, R. J., Roy, R. R., Whiting, W. C., Lovely, R. G., Hodgson, J. A., & Edgerton, V. R. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90281-3 · Cited by 218
Metadata
- Authors
- Shapiro, R.
- Venue
- Research Quarterly. American Alliance for Health, Physical Education and Recreation
- Publisher
- Informa UK Limited
- Published
- 1978-05
- Volume
- 49
- Issue
- 2
- Pages
- 197-205
- ISSN
- 0034-5377 (ISSN-L)
- 1067-1315
- OpenAlex
- W1634835673
- Cited by
- 201
- References
- 3
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.