Supervisory and Optimal Control of Building HVAC Systems: A Review
Abstract
HVAC systems are the major energy consumers in buildings. Operation and control of HVAC systems have significant impacts on the energy or cost efficiency of buildings besides their designs. Buildings nowadays are mostly equipped with comprehensive building automation systems (BASs) and building energy management control systems (EMCSs) that allow the possibility of enhancing and optimizing the operation and control of HVAC systems. Supervisory and optimal control, which addresses the energy or cost-efficient control of HVAC systems while providing the desired indoor comfort and healthy environment under the dynamic working conditions, is attracting more attention of the building professionals and the society and provides incentives to make more efforts in developing more extensive and robust control methods for HVAC systems. This paper provides a framework for categorizing the main supervisory and optimal control methods and optimization techniques developed and/or utilized in the HVAC field. The application characteristics of each control method and optimization technique are also identified and compared. A comprehensive overall review of the state of the art of the research and development, as well as application of supervisory and optimal control, in HVAC systems is also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
All you need to know about model predictive control for buildings
Drgoňa, J., Arroyo, J., Cupeiro Figueroa, I., Blum, D., Arendt, K., Kim, D., Ollé, E. P., Oravec, J., Wetter, M., Vrabie, D. L., et al. (2020) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2020.09.001 · Cited by 1,020
Reinforcement learning for demand response: A review of algorithms and modeling techniques
Vázquez-Canteli, J. R., & Nagy, Z. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.11.002 · Cited by 883
Afram, A., Janabi-Sharifi, F., Fung, A. S., & Raahemifar, K. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.02.012 · Cited by 655
Serale, G., Fiorentini, M., Capozzoli, A., Bernardini, D., & Bemporad, A. (2018) · Energies · doi:10.3390/en11030631 · Cited by 637
Modeling techniques used in building HVAC control systems: A review
Afroz, Z., Shafiullah, G., Urmee, T., & Higgins, G. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.10.044 · Cited by 411
Metadata
- Authors
- Wang, S., & Ma, Z.
- Venue
- HVAC&R Research
- Publisher
- Informa UK Limited
- Published
- 2008-01
- Volume
- 14
- Issue
- 1
- Pages
- 3-32
- ISSN
- 1078-9669 (ISSN-L)
- 1938-5587
- OpenAlex
- W2018614621
- Cited by
- 496
- References
- 0
- FWCI
- 37.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Supervisory and Optimal Control of Building HVAC Systems: A Review. https://app.cochat.ai/papers/10.1080/10789669.2008.10390991
- The paper
- Wang, S., & Ma, Z. (2008). Supervisory and Optimal Control of Building HVAC Systems: A Review. HVAC&R Research. https://doi.org/10.1080/10789669.2008.10390991
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.