Implementation of model predictive control for an HVAC system in a mid-size commercial building
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The article presents field experiment results from the implementation of a model predictive controller which optimizes the operation of a variable volume, dual-duct, multi-zone HVAC unit serving an existing mid-size commercial building. This full-scale proof-of-concept study was used to estimate the benefits of implementing advanced building control technologies during a retrofit. The control approach uses dynamic estimates and predictions of zone loads and temperatures, outdoor weather conditions, and HVAC system models to minimize energy consumption while meeting equipment and thermal comfort constraints. The article describes the on-line implementation of the hierarchical control system, including communication of the optimal control scheme with the building automation system, the controlled set-points and the component-level feedback loops, as well as the measured energy and indoor comfort performance benefits from the demonstration. The building-scale experiments and the receding-horizon control algorithm implementation results are described. Site measurements show this algorithm, when implemented in state-of-the-art direct digital control systems, consistently yields energy savings and reduces peak power while improving the indoor thermal comfort. The demonstration results show energy savings of 20% on average during the transition season, 70% on average during heating season, and 10% or more peak power reduction, all relative to pre-configured, rule-based schedules implemented in the retrofitted direct digital control system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wächter, A., & Biegler, L. T. (2006) · Mathematical Programming · doi:10.1007/s10107-004-0559-y · Cited by 9,483
Constrained model predictive control: Stability and optimality
Mayne, D. Q., Rawlings, J. B., Rao, C. V., & Scokaert, P. O. M. (2000) · Automatica · doi:10.1016/s0005-1098(99)00214-9 · Cited by 8,736
Model predictive control: past, present and future
Morari, M., & H. Lee, J. (1999) · Computers & Chemical Engineering · doi:10.1016/s0098-1354(98)00301-9 · Cited by 2,335
Cited by
Serale, G., Fiorentini, M., Capozzoli, A., Bernardini, D., & Bemporad, A. (2018) · Energies · doi:10.3390/en11030631 · Cited by 637
“Up to date, the Illawarra Flame house [67–69] in Wollongong and 10 households in Brugg [111], the 3E Headquarters in Brussels [149] and a commercial Building in Allschwil [82,116], a building of the Czech Technical University in Prague [115,153], the UC Merced Campus [62] and the Engineers Construction Engineering Res…”
Sturzenegger, D., Gyalistras, D., Morari, M., & Smith, R. S. (2016) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2015.2415411 · Cited by 387
Pang, Z., Niu, F., & O’Neill, Z. (2020) · Renewable Energy · doi:10.1016/j.renene.2020.04.042 · Cited by 339
Park, J. Y., & Nagy, Z. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.102 · Cited by 299
A critical review of field implementations of occupant-centric building controls
Park, J. Y., Ouf, M. M., Gunay, B., Peng, Y., O'Brien, W., Kjærgaard, M. B., & Nagy, Z. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106351 · Cited by 274
Metadata
- Authors
- Bengea, S. C., Kelman, A. D., Borrelli, F., Taylor, R., & Narayanan, S.
- Venue
- HVAC&R Research
- Publisher
- Informa UK Limited
- Published
- 2014-01
- Volume
- 20
- Issue
- 1
- Pages
- 121-135
- ISSN
- 1078-9669 (ISSN-L)
- 1938-5587
- OpenAlex
- W1979607444
- Cited by
- 141
- References
- 3
- FWCI
- 22.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implementation of model predictive control for an HVAC system in a mid-size commercial building. https://app.cochat.ai/papers/10.1080/10789669.2013.834781
- The paper
- Bengea, S. C., Kelman, A. D., Borrelli, F., Taylor, R., & Narayanan, S. (2014). Implementation of model predictive control for an HVAC system in a mid-size commercial building. HVAC&R Research. https://doi.org/10.1080/10789669.2013.834781
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.