Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 236

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Functional Recovery Measures for Spinal Cord Injury: An Evidence-Based Review for Clinical Practice and Research: Report of the National Institute on Disability and Rehabilitation Research Spinal Cord Injury Measures Meeting

Open access
Anderson, Kim, Aito, Sergio, Atkins, Michal, Biering-Sørensen, Fin, Charlifue, Susan, Curt, Armin, Ditunno, John, Glass, Clive, Marino, Ralph, Marshall, Ruth, Mulcahey, Mary Jane, Post, Marcel, Savic, Gordana, Scivoletto, Giorgio, Catz, Amiram·2008·The Journal of Spinal Cord Medicine

Abstract

BACKGROUND/OBJECTIVE: The end goal of clinical care and clinical research involving spinal cord injury (SCI) is to improve the overall ability of persons living with SCI to function on a daily basis. Neurologic recovery does not always translate into functional recovery. Thus, sensitive outcome measures designed to assess functional status relevant to SCI are important to develop. METHOD: Evaluation of currently available SCI functional outcome measures by a multinational work group. RESULTS: The 4 measures that fit the prespecified inclusion criteria were the Modified Barthel Index (MBI), the Functional Independence Measure (FIM), the Quadriplegia Index of Function (QIF), and the Spinal Cord Independence Measure (SCIM). The MBI and the QIF were found to have minimal evidence for validity, whereas the FIM and the SCIM were found to be reliable and valid. The MBI has little clinical utility for use in the SCI population. Likewise, the FIM applies mainly when measuring burden of care, which is not necessarily a reflection of functional recovery. The QIF is useful for measuring functional recovery but only in a subpopulation of people with SCI, and substantial validity data are still required. The SCIM is the only functional recovery outcome measure designed specifically for SCI. CONCLUSIONS: The multinational work group recommends that the latest version of the SCIM (SCIM III) continue to be refined and validated and subsequently implemented worldwide as the primary functional recovery outcome measure for SCI. The QIF may continue to be developed and validated for use as a supplemental tool for the nonambulatory tetraplegic population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/10790268.2008.11760704

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 236

Metadata

Authors
Anderson, K., Aito, S., Atkins, M., Biering-Sørensen, F., Charlifue, S., Curt, A., Ditunno, J., Glass, C., Marino, R., Marshall, R., Mulcahey, M. J., Post, M., Savic, G., Scivoletto, G., & Catz, A.
Venue
The Journal of Spinal Cord Medicine
Published
2008-01
Volume
31
Issue
2
Pages
133-144
ISSN
  • 1079-0268 (ISSN-L)
  • 2045-7723
OpenAlex
W2582440138
Cited by
236
References
2
FWCI
5.27
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Functional Recovery Measures for Spinal Cord Injury: An Evidence-Based Review for Clinical Practice and Research: Report of the National Institute on Disability and Rehabilitation Research Spinal Cord Injury Measures Meeting. https://app.cochat.ai/papers/10.1080/10790268.2008.11760704
The paper
Anderson, K., Aito, S., Atkins, M., Biering-Sørensen, F., Charlifue, S., Curt, A., Ditunno, J., Glass, C., Marino, R., Marshall, R., Mulcahey, M. J., Post, M., Savic, G., Scivoletto, G., & Catz, A. (2008). Functional Recovery Measures for Spinal Cord Injury: An Evidence-Based Review for Clinical Practice and Research: Report of the National Institute on Disability and Rehabilitation Research Spinal Cord Injury Measures Meeting. The Journal of Spinal Cord Medicine. https://doi.org/10.1080/10790268.2008.11760704

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.