ULTRASOUND-ASSISTED EMULSIFICATION MICROEXTRACTION OF VARIOUS PRESERVATIVES FROM COSMETICS, BEVERAGES, AND WATER SAMPLES
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In the present work, an efficient method based on ultrasound-assisted emulsification microextraction was developed for the determination of sodium benzoate (SB), p-hydroxybenzoic acid (PHBA), methyl-paraben (MP), ethyl-paraben (EP), and propyl-paraben (PP) in different samples. In this procedure, 40 μL of (5% w/v) aliquot 336 in 1-octanol was injected slowly into a 12-mL home-designed centrifuge glass vial containing an aqueous sample of the analytes that was located inside the ultrasonic water bath. The formed emulsion was centrifuged and the separated organic solvent was then injected into a 20-μL loop of high performance liquid chromatography coupled with UV detector. Under the optimum conditions, preconcentration factors (PFs) in the range of 109–490 were obtained. The performance of the proposed method was studied in terms of its linear range (LR, 0.6 μg/L up to 10000 μg/L), linearity (R2 ≥ 0.9963), precision [RSD% ≤ 3.6; reproducibility, RSD (%) ≤ 9.8] and extraction recoveries (22.6–102.1%). Limits of detections (LODs) were 8.3, 1.2, 0.60, 0.42, and 0.25 μg/L for SB, PHBA, MP, EP, and PP, respectively. Finally, the applicability of the proposed method was evaluated by the extraction and determination of the target analytes from beverages, cosmetics, and water samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Safety assessment of esters of p-hydroxybenzoic acid (parabens)
Soni, M. G., Carabin, I. G., & Burdock, G. A. (2005) · Food and Chemical Toxicology · doi:10.1016/j.fct.2005.01.020 · Cited by 1,012 · cited 1×
“However, in practice, shorter esters are commonly employed because of their higher solubility in water;([6,8]) methyl (MP) and propyl-paraben (PP) are the most widely used.([9,10]) Combinations of two or more parabens are often used to increase the ability of the system to withstand microbial contaminations.”
BackgroundConcentrations of parabens in human breast tumours
Darbre, P. D., Aljarrah, A., Miller, W. R., Coldham, N. G., Sauer, M. J., & Pope, G. S. (2004) · Journal of Applied Toxicology · doi:10.1002/jat.958 · Cited by 805 · cited 1×
“Parabens are oestrogenic, affect the human endocrine system, and probably cause breast cancer,([5,13]) as well as male reproductive disorders.”
BackgroundRegueiro, J., Llompart, M., Garcia-Jares, C., Garcia-Monteagudo, J. C., & Cela, R. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.091 · Cited by 547 · cited 2×
“On the other hand, as the ionic strength of the medium increases, the viscosity and density also increase; this diminishes the efficiency of the mass transfer process and, consequently, the extraction efficiency of the technique.([33]) Additionally, the ultrasound waves can be absorbed and dispersed in a viscose medium”
BackgroundMethodOzcan, S., Tor, A., & Aydin, M. E. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.06.037 · Cited by 113 · cited 1×
“Recently, this technique was applied for the determination of organochlorine pesticides,([34]) polychlorinated biphenyls,([35]) polybrominated flame retardants,([36]) aromatic amines,([37]) and some phenolic preservatives (including parabens)([38]) in water samples.”
Method
Cited by
Dispersive liquid–liquid microextraction in food analysis. A critical review
Viñas, P., Campillo, N., López-García, I., & Hernández-Córdoba, M. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7344-9 · Cited by 211
“This version of DLLME has become known as inverted DLLME (I-DLLME), in which solvents such as 1-octanol [66, 68, 69, 80] and 2-ethyl-1-hexanol [52] have been used (Table 2).”
BackgroundMethodInfluentialOcaña-González, J. A., Villar-Navarro, M., Ramos-Payán, M., Fernández-Torres, R., & Bello-López, M. A. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.07.002 · Cited by 129
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Development and challenges of supramolecular solvents in liquid-based microextraction methods
Moradi, M., Yamini, Y., & Feizi, N. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116231 · Cited by 74
Self-citationCao, J., Liu, Y., & Zhao, F. (2022) · Green Chemistry · doi:10.1039/d2gc02097a · Cited by 24
Metadata
- Authors
- Yamini, Y., Saleh, A., Rezaee, M., Ranjbar, L., & Moradi, M.
- Venue
- Journal of Liquid Chromatography & Related Technologies
- Publisher
- Informa UK Limited
- Published
- 2012-01
- Volume
- 35
- Issue
- 18
- Pages
- 2623-2642
- ISSN
- 1082-6076 (ISSN-L)
- 1520-572X
- OpenAlex
- W1569769551
- Cited by
- 36
- References
- 4
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.