The DOI matches its Crossref record.
The ptl, combitube, laryngeal mask, and oral airway: A randomized prehospital comparative study of ventilatory device effectiveness and cost-effectiveness in 470 cases of cardiorespiratory arrest
Abstract
PURPOSE: A prehospital study was conducted to assess and compare three alternative airway devices and the oral airway for use by non-Advanced Life Support emergency medical assistants (EMAs). METHOD: A modified randomized crossover design was used. The Pharyngeal Tracheal Lumen Airway (PTL), the laryngeal mask (LM), and the esophageal tracheal Combitube (Combi) were compared objectively for success of insertion, ventilation, and arterial blood gas and spirometry measurements performed upon hospital arrival. Subjective assessment was carried out by EMAs and receiving physicians at the time of device use, and an eight-question comparative evaluation of all devices was completed by EMAs at study conclusion. A comparative cost analysis was performed. Operating room training was compared with mannequin training for the LM. Autopsy findings and survival to hospital discharge were analyzed. The study took place in four non-ALS communities over four and a half years, and involved 470 patients in cardiac and/or respiratory arrest. EMAs had automatic external defibrillator training but no endotracheal intubation skills. RESULTS: Successful insertion and ventilation: Combi, 86%; PTL, 82%; LM, 73% (p = 0.048). No significant difference was found for objective measurements of ventilatory effectiveness (ABGs and spirometry). Significant comparative differences in subjective evaluation were found. CONCLUSIONS: The PTL, LM, and Combi appear to offer substantial advances over the OA/BVM system. Although the most costly, the Combitube was associated with the least problems with ventilation and was the most preferred by a majority of EMAs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Deakin, C. D., Nolan, J. P., Soar, J., Sunde, K., Koster, R. W., Smith, G. B., & Perkins, G. D. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.017 · Cited by 2,700
Neumar, R. W., Otto, C. W., Link, M. S., Kronick, S. L., Shuster, M., Callaway, C. W., Kudenchuk, P. J., Ornato, J. P., McNally, B., Silvers, S. M., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.970988 · Cited by 1,634
European Resuscitation Council Guidelines for Resuscitation 2010 Section 1. Executive summary
Nolan, J. P., Soar, J., Zideman, D. A., Biarent, D., Bossaert, L. L., Deakin, C., Koster, R. W., Wyllie, J., & Böttiger, B. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.021 · Cited by 1,375
European Resuscitation Council Guidelines for Resuscitation 2005
Nolan, J. P., Deakin, C. D., Soar, J., Böttiger, B. W., & Smith, G. (2005) · Resuscitation · doi:10.1016/j.resuscitation.2005.10.009 · Cited by 834
European Resuscitation Council Guidelines for Resuscitation 2005
Soar, J., Deakin, C. D., Nolan, J. P., Abbas, G., Alfonzo, A., Handley, A. J., Lockey, D., Perkins, G. D., & Thies, K. (2005) · Resuscitation · doi:10.1016/j.resuscitation.2005.10.004 · Cited by 832
Metadata
- Authors
- Rumball, C. J., & MacDonald, D.
- Venue
- Prehospital Emergency Care
- Publisher
- Informa UK Limited
- Published
- 1997-01
- Volume
- 1
- Issue
- 1
- Pages
- 1-10
- ISSN
- 1090-3127 (ISSN-L)
- 1545-0066
- OpenAlex
- W1994033071
- Cited by
- 225
- References
- 0
- FWCI
- 12.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The ptl, combitube, laryngeal mask, and oral airway: A randomized prehospital comparative study of ventilatory device effectiveness and cost-effectiveness in 470 cases of cardiorespiratory arrest. https://app.cochat.ai/papers/10.1080/10903129708958776
- The paper
- Rumball, C. J., & MacDonald, D. (1997). The ptl, combitube, laryngeal mask, and oral airway: A randomized prehospital comparative study of ventilatory device effectiveness and cost-effectiveness in 470 cases of cardiorespiratory arrest. Prehospital Emergency Care. https://doi.org/10.1080/10903129708958776
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.