The DOI matches its Crossref record.
Fixed wavelength fluorescence (FF) of bile as a monitoring tool for polyaromatic hydrocarbon exposure in fish: an evaluation of compound specificity, inner filter effect and signal interpretation
Abstract
Fixed wavelength fluorescence (FF) of bile has been evaluated as a monitoring tool for the screening of polyaromatic hydrocarbon (PAH) contamination in fish. The methodology was studied through laboratory and field experiments with Atlantic cod (Gadus morhua L.) and flounder (Platichthys flesus L.) exposed to various forms of PAH contamination. The present study demonstrates the ability of FF screening to discriminate between 2-, 4- and 5-ring PAH metabolites by using the wavelength pairs 290/335 nm, 341/383 nm and 380/430 nm, respectively. In general, the degree of fluorescence interference between these metabolite groups appears to be low. Dose- and time-response patterns of the FF signals were shown to give a good reflection of the PAH exposure. Further, the necessity of an appropriate dilution of bile samples prior to fluorescence measurements is demonstrated by a study of inner filter effect. Normally a dilution of 1000-2000-fold is necessary. Individual differences in the bile density, e.g. measured as the concentration of the bile pigment biliverdin, have to be allowed for when applying the FF method. However, it is shown that normalizing the FF signals to biliverdin concentrations on an individual basis added extra error to the data set. The simple, rapid and cost-effective FF method is found to be well suited for screening fish for PAH contamination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Viarengo, A., Lowe, D., Bolognesi, C., Fabbri, E., & Koehler, A. (2007) · Comparative Biochemistry and Physiology Part C: Toxicology & Pharmacology · doi:10.1016/j.cbpc.2007.04.011 · Cited by 677
Bakke, T., Klungsøyr, J., & Sanni, S. (2013) · Marine Environmental Research · doi:10.1016/j.marenvres.2013.09.012 · Cited by 421
Polycyclic Aromatic Hydrocarbon (PAH) Ecotoxicology in Marine Ecosystems
Hylland, K. (2006) · Journal of Toxicology and Environmental Health, Part A · doi:10.1080/15287390500259327 · Cited by 366
Aas, E. (2000) · Aquatic Toxicology · doi:10.1016/s0166-445x(00)00108-9 · Cited by 354
Self-citationRibeiro, C. A. O., Vollaire, Y., Sanchez-Chardi, A., & Roche, H. (2005) · Aquatic Toxicology · doi:10.1016/j.aquatox.2005.04.008 · Cited by 352
Metadata
- Authors
- AAS, E., BEYER, J., & GOKSOYR, A.
- Venue
- Biomarkers
- Publisher
- Informa UK Limited
- Published
- 2000-01
- Volume
- 5
- Issue
- 1
- Pages
- 9-23
- ISSN
- 1354-750X (ISSN-L)
- 1366-5804
- OpenAlex
- W2122636743
- Cited by
- 182
- References
- 0
- FWCI
- 4.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fixed wavelength fluorescence (FF) of bile as a monitoring tool for polyaromatic hydrocarbon exposure in fish: an evaluation of compound specificity, inner filter effect and signal interpretation. https://app.cochat.ai/papers/10.1080/135475000230505
- The paper
- AAS, E., BEYER, J., & GOKSOYR, A. (2000). Fixed wavelength fluorescence (FF) of bile as a monitoring tool for polyaromatic hydrocarbon exposure in fish: an evaluation of compound specificity, inner filter effect and signal interpretation. Biomarkers. https://doi.org/10.1080/135475000230505
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.