Investigations of the impact of altered auditory feedback in‐the‐ear devices on the speech of people who stutter: initial fitting and 4‐month follow‐up
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Self‐contained ear‐level devices delivering altered auditory feedback (AAF) for the application with those who stutter have only been recently developed. Aims: The paper examines the first therapeutic application of self‐contained ear‐level devices in three experiments. The effect of the device on the proportion of stuttered syllables and speech naturalness was investigated following initial fitting and at 4 months post‐fitting. Methods & Procedures: Three experiments were undertaken: In Experiment 1, the effect of a self‐contained in‐the‐ear device delivering AAF was investigated with those who stutter during reading and monologue. Two adolescents and five adults who stuttered read and produced monologue with and without a device fit monaurally. The device provided a frequency shift of +500 Hz in combination with a delayed auditory feedback of 60 ms. Custom‐made ITC and CIC devices were fabricated for four adults and four youths in Experiment 2. The effect of group (i.e. youth versus adult), time (i.e. initial fitting versus 4‐month follow‐up), speech task (i.e. reading versus monologue), and device (i.e. present versus absent) on stuttering rate was examined. In Experiment 3, 15 naïve listeners rated the speech naturalness of speech produced by the participants in Experiment 2. Speech samples from six conditions were rated: reading and monologue without the device at the initial visit, reading and monologue with the device at the initial visit, and reading and monologue with the device at 4 months. Outcomes & Results: In Experiment 1, the proportion of stuttered syllables was significantly (p=0.011) reduced by approximately 90% during reading and 67% during monologue with the device relative to no device. Only a significant main effect of device (p=0.0028) was found in Experiment 2. That is, stuttering rate was significantly reduced with the device in place regardless of speech task or group and remained so 4 months later. In Experiment 3, speech samples generated while wearing the device were judged to be more natural sounding than those without the device (p<0.0001) for reading and monologue with both adults and youths. There was no significant difference between the mean naturalness ratings of speech samples generated during the initial fitting with the device relative to that at 4 months with the device (p>0.05) in all cases except with the youths while engaged in monologue. For that condition, raters judged the speech produced at the initial fitting as more natural. Conclusions: These findings support the notion that a self‐contained in‐the‐ear device delivering AAF assists those who stutter. With the device in place, stuttering is reduced and speech produced is judged to be more natural than with out the device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Andrews (1983) · doi:10.1044/jshd.4803.226 · Cited by 419
Cited by
Baxter, S., Johnson, M., Blank, L., Cantrell, A., Brumfitt, S., Enderby, P., & Goyder, E. (2015) · International Journal of Language & Communication Disorders · doi:10.1111/1460-6984.12171 · Cited by 89
Antipova, E. A., Purdy, S. C., Blakeley, M., & Williams, S. (2008) · Journal of Fluency Disorders · doi:10.1016/j.jfludis.2008.09.002 · Cited by 51
Ritto, A. P., Juste, F. S., Stuart, A., Kalinowski, J., & de Andrade, C. R. F. (2016) · International Journal of Language & Communication Disorders · doi:10.1111/1460-6984.12237 · Cited by 24
Self-citationMoein, N., Mohamadi, R., Rostami, R., Nitsche, M., Zomorrodi, R., & Ostadi, A. (2022) · Journal of Fluency Disorders · doi:10.1016/j.jfludis.2022.105907 · Cited by 16
Metadata
- Authors
- Stuart, A., Kalinowski, J., Rastatter, M. P., Saltuklaroglu, T., & Dayalu, V.
- Venue
- International Journal of Language & Communication Disorders
- Publisher
- Wiley
- Published
- 2004-01-03
- Volume
- 39
- Issue
- 1
- Pages
- 93-113
- ISSN
- 1368-2822 (ISSN-L)
- 1460-6984
- OpenAlex
- W2129872528
- Cited by
- 68
- References
- 2
- FWCI
- 4.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.