Steady‐state nicotine plasma levels following use of four different types of Swedish snus compared with 2‐mg Nicorette chewing gum: A crossover study
Abstract
The present study evaluated nicotine plasma levels achieved following 1 day's regular use of four commonly used brands of Swedish portion snus and 2-mg Nicorette chewing gum. The study also estimated the amount of sodium chloride extracted from each snus sachet to identify potential risks for exacerbation of heart failure and hypertension with the use of Swedish snus. Extracted dose of nicotine, area under the venous plasma concentration-time curve (AUC), maximum plasma nicotine concentration (Cmax) of the last (12th) dosing interval, and the Cmax and AUC ratios versus Nicorette were calculated. Relative bioavailable dose was calculated using AUC of 2-mg Nicorette gum as the reference. The mean extracted nicotine doses were 2.74+/-0.80, 1.55+/-0.68, 2.00+/-0.56, and 1.08+/-0.94 mg/sachet for General, Catch Licorice, Catch Mini, and Catch Dry Mini snus, respectively. The approximate bioavailable dose of nicotine from snus was 40%-60% of the extracted dose. The steady-state nicotine plasma concentration-time curve for the weakest brand, Catch Dry Mini portion snus, did not differ significantly from that of the 2-mg Nicorette gum. The AUC and Cmax for Catch Licorice 1 g and Catch Mini 0.5 g portion snus were twice those for the 2-mg Nicorette gum; for the strongest brand, General, these values were 2(1/2) times those for Nicorette gum. The differences in AUC and Cmax versus the 2-mg Nicorette gum were statistically significant (p=.020). Nicotine plasma levels with General portio…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Previous studies have reported greater AUC and Cmax values for some types of snus than for cigarettes, probably due to the longer period of snus use relative to smoking a single cigarette.
“previous studies have similarly reported greater AUC and Cmax values for some types of snus than for cigarettes [25–27], probably due to the longer period of snus use relative to smoking a single cigarette.”
From A Randomised Study to Investigate the Nicotine Pharmacokinetics of Oral Nicotine Pouches and a Combustible Cigarette (2022) · cites this paper as [26]
Cited by
Sorted by citations
Lunell, E., Fagerström, K., Hughes, J., & Pendrill, R. (2020) · Nicotine & Tobacco Research · doi:10.1093/ntr/ntaa068 · Cited by 121 · see citing works
Self-citationMcEwan, M., Azzopardi, D., Gale, N., Camacho, O. M., Hardie, G., Fearon, I. M., & Murphy, J. (2022) · European Journal of Drug Metabolism and Pharmacokinetics · doi:10.1007/s13318-021-00742-9 · Cited by 70 · see citing works
Liu, J., Rensch, J., Wang, J., Jin, X., Vansickel, A., Edmiston, J., & Sarkar, M. (2022) · Psychopharmacology · doi:10.1007/s00213-022-06172-y · Cited by 37 · see citing works
- Authors
- Lunell, E., & Lunell, M.
- Venue
- Nicotine & Tobacco Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-06-01
- Volume
- 7
- Issue
- 3
- Pages
- 397-403
- ISSN
- 1462-2203
- 1469-994X
- Cited by
- 61
- References
- 0
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›