A Review of CO 2 Measurement Procedures in Ventilation Research
Abstract
It is widely recognised that the carbon dioxide (CO2) concentration level inside a building is a reflection of the indoor air quality in that building. In most buildings, occupants are a major source of CO2 through exhalation. It is generally accepted that the concentration of CO2 varies with location (horizontal and vertical) within an enclosed space and this can impact on the variation of indoor air quality within the space. Hence, measurement errors related to CO2 sampling strategies in a space are important as they can lead to uncertainties in the mean concentration for the space. The aim of this paper is to investigate existing measurement practices and sampling locations and how these influence the CO2 concentrations monitored in buildings. To identify the work done in CO2 measurement practice and determine the current limitations in establishing representative locations for CO2 concentration in buildings, two main approaches were used: (i) an extensive literature review of existing knowledge from peer reviewed articles and other relevant documents (database); (ii) the use of questionnaires to identify reported measurements with CO2 sensors as representation of research methods applied by professionals and research organisations. The findings show that most researchers (based on the database and questionnaires analysed) prefer heights between 1.0 m to 1.2 m in the middle of an occupied zone as a representative location. This compares to the recognised breathing zone hei…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 47 · Cited by 73
Metadata
- Authors
- Mahyuddin, N., & Awbi, H.
- Affiliations
- University of Malaya (MY)
- University of Reading (GB)
- Venue
- International Journal of Ventilation
- Publisher
- Informa UK Limited
- Published
- 2012-03
- Volume
- 10
- Issue
- 4
- Pages
- 353-370
- ISSN
- 1473-3315 (ISSN-L)
- 2044-4044
- OpenAlex
- W2187265948
- Cited by
- 73
- References
- 47
- Citations by year
- 2026: 6 · 2025: 3 · 2024: 2 · 2023: 4 · 2022: 6 · 2021: 13 · 2020: 14 · 2019: 5 · 2018: 6 · 2017: 4 · 2016: 3 · 2015: 1 · 2014: 2 · 2013: 3
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Ventilation (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Environmental Science › Environmental Engineering › Wind and Air Flow Studies
- Keywords
- carbon dioxide measurement, indoor air quality, sampling sites, measurement uncertainty, CO2 sensor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Review of CO 2 Measurement Procedures in Ventilation Research. https://app.cochat.ai/papers/10.1080/14733315.2012.11683961
- The paper
- Mahyuddin, N., & Awbi, H. (2012). A Review of CO 2 Measurement Procedures in Ventilation Research. International Journal of Ventilation. https://doi.org/10.1080/14733315.2012.11683961